Compaq SCSI Logical Drive Condition.
This is the overall condition of the logical drive and all of the
physical drives which comprise it.
The following values are defined:
other(1)
The management agent does not recognize the status. You may
need to upgrade your software.
ok(2)
The logical drive and all of its physical drives are operating
normally. No user action is required.
degraded(3)
Either the logical drive is degraded or one or more of its
physical drives is degraded. You need to check the status
of the logical drive and of all its physical drives.
failed(4)
Either the logical drive has failed or one or more of its
physical drives has failed. You need to check the status
of the logical drive and of all its physical drives.
Parsed from file CPQSCSI1.MIB.txt
Company: None
Module: CPQSCSI-MIB
SCSI Logical Drive Condition.
This is the overall condition of the logical drive and all of the
physical drives which comprise it.
The following values are defined:
other(1)
The management agent does not recognize the status. You may
need to upgrade your software.
ok(2)
The logical drive and all of its physical drives are operating
normally. No user action is required.
degraded(3)
Either the logical drive is degraded or one or more of its
physical drives is degraded. You need to check the status
of the logical drive and of all its physical drives.
failed(4)
Either the logical drive has failed or one or more of its
physical drives has failed. You need to check the status
of the logical drive and of all its physical drives.
Parsed from file CPQSCSI-MIB.mib
Module: CPQSCSI-MIB
cpqScsiLogDrvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS deprecated DESCRIPTION "Compaq SCSI Logical Drive Condition. This is the overall condition of the logical drive and all of the physical drives which comprise it. The following values are defined: other(1) The management agent does not recognize the status. You may need to upgrade your software. ok(2) The logical drive and all of its physical drives are operating normally. No user action is required. degraded(3) Either the logical drive is degraded or one or more of its physical drives is degraded. You need to check the status of the logical drive and of all its physical drives. failed(4) Either the logical drive has failed or one or more of its physical drives has failed. You need to check the status of the logical drive and of all its physical drives." ::= { cpqScsiLogDrvEntry 8 }
Vendor: Compaq
Module: CPQSCSI-MIB
[Automatically extracted from oidview.com]
cpqScsiLogDrvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "SCSI Logical Drive Condition. This is the overall condition of the logical drive and all of the physical drives which comprise it. The following values are defined: other(1) The management agent does not recognize the status. You may need to upgrade your software. ok(2) The logical drive and all of its physical drives are operating normally. No user action is required. degraded(3) Either the logical drive is degraded or one or more of its physical drives is degraded. You need to check the status of the logical drive and of all its physical drives. failed(4) Either the logical drive has failed or one or more of its physical drives has failed. You need to check the status of the logical drive and of all its physical drives." ::= { cpqScsiLogDrvEntry 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.5.2.3.1.1.1 | cpqScsiLogDrvCntlrIndex | 0 | 0 | SCSI Logical Drive Controller Index. The controller index indicates to which SCSI adapter instance this table entry belongs. |
1.3.6.1.4.1.232.5.2.3.1.1.2 | cpqScsiLogDrvBusIndex | 0 | 0 | SCSI Logical Drive Bus Index. The bus index indicates to which SCSI bus instance on an adapter this table entry belongs. |
1.3.6.1.4.1.232.5.2.3.1.1.3 | cpqScsiLogDrvIndex | 0 | 0 | SCSI Logical Drive Index. The logical drive index indicates to which logical drive instance on a SCSI bus this table entry belong… |
1.3.6.1.4.1.232.5.2.3.1.1.4 | cpqScsiLogDrvFaultTol | 0 | 0 | Compaq SCSI Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. To change the fault toleranc… |
1.3.6.1.4.1.232.5.2.3.1.1.5 | cpqScsiLogDrvStatus | 0 | 0 | Compaq SCSI Logical Drive Status. The logical drive can be in one of the following states: other(1) The management agent does not … |
1.3.6.1.4.1.232.5.2.3.1.1.6 | cpqScsiLogDrvSize | 0 | 0 | SCSI Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (… |
1.3.6.1.4.1.232.5.2.3.1.1.7 | cpqScsiLogDrvPhyDrvIDs | 0 | 0 | SCSI Logical Drive Physical Drive IDs. This lists the physical drive SCSI ID's which are associated with this logical drive. The… |
1.3.6.1.4.1.232.5.2.3.1.1.9 | cpqScsiLogDrvStripeSize | 0 | 0 | Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.5.2.3.1.1.10 | cpqScsiLogDrvAvailSpares | 0 | 0 | SCSI Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that are not c… |
1.3.6.1.4.1.232.5.2.3.1.1.11 | cpqScsiLogDrvPercentRebuild | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |
1.3.6.1.4.1.232.5.2.3.1.1.12 | cpqScsiLogDrvOsName | 0 | 0 | Logical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the agent does not… |