Compaq Storage System Backplane Fan Status.
This is the current status of the fans in the storage system.
This value will be one of the following:
other(1)
The agent is unable to determine if this storage system has
fan monitoring.
notInstalled(2)
This unit does not support fan monitoring.
ok(3)
All fans are working normally.
degraded(4)
At least one storage system fan has failed, but there is still
sufficient cooling capacity to allow the system to continue.
The fan should be replaced.
failed(5)
One or more storage system fans have failed. The fan(s) should
be replaced immediately to avoid hardware damage.
notSupported(6)
The storage system does not support reporting fan status
through this backplane. The fan status is reported through the
first backplane on this storage system.
Parsed from file CPQSTSYS2.MIB.txt
Company: None
Module: CPQSTSYS-MIB
Storage System Backplane Fan Status.
This is the current status of the fans in the storage system.
This value will be one of the following:
other(1)
The agent is unable to determine if this storage system has
fan monitoring.
notInstalled(2)
This unit does not support fan monitoring.
ok(3)
All fans are working normally.
degraded(4)
At least one storage system fan has failed, but there is still
sufficient cooling capacity to allow the system to continue.
The fan should be replaced.
failed(5)
One or more storage system fans have failed. The fan(s) should
be replaced immediately to avoid hardware damage.
notSupported(6)
The storage system does not support reporting fan status
through this backplane. The fan status is reported through the
first backplane on this storage system.
degraded-Fan1Failed(7)
Fan 1 has failed, but there is still sufficient cooling
capacity to allow the system to continue. The fan should be
replaced.
degraded-Fan2Failed(8)
Fan 2 has failed, but there is still sufficient cooling
capacity to allow the system to continue. The fan should be
replaced.
Parsed from file CPQSTSYS-MIB.mib
Module: CPQSTSYS-MIB
cpqSsBackplaneFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), degraded(4), failed(5), notSupported(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system." ::= { cpqSsBackplaneEntry 10 }
Vendor: Compaq
Module: CPQSTSYS-MIB
[Automatically extracted from oidview.com]
cpqSsBackplaneFanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInstalled(2), ok(3), degraded(4), failed(5), notSupported(6), degraded-Fan1Failed(7), degraded-Fan2Failed(8) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system. degraded-Fan1Failed(7) Fan 1 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. degraded-Fan2Failed(8) Fan 2 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced." ::= { cpqSsBackplaneEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.8.2.2.6.1.1 | cpqSsBackplaneChassisIndex | 0 | 0 | Storage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis. |
1.3.6.1.4.1.232.8.2.2.6.1.2 | cpqSsBackplaneIndex | 0 | 0 | Storage System Backplane Index. This index uniquely identifies a storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.3 | cpqSsBackplaneFWRev | 0 | 0 | Storage System Backplane Firmware Revision. This is the revision level of storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.4 | cpqSsBackplaneDriveBays | 0 | 0 | Storage System Backplane Drive Bays. This is the number of bays on this storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.5 | cpqSsBackplaneDuplexOption | 0 | 0 | Storage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this stora… |
1.3.6.1.4.1.232.8.2.2.6.1.6 | cpqSsBackplaneCondition | 0 | 0 | Storage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The … |
1.3.6.1.4.1.232.8.2.2.6.1.7 | cpqSsBackplaneVersion | 0 | 0 | Storage System Backplane Version. This is the version of the drive box back plane. |
1.3.6.1.4.1.232.8.2.2.6.1.8 | cpqSsBackplaneVendor | 0 | 0 | Storage System Backplane Vendor This is the storage box's vendor name. This can be used for identification purposes. |
1.3.6.1.4.1.232.8.2.2.6.1.9 | cpqSsBackplaneModel | 0 | 0 | Storage System Backplane Model. This is a description of the storage system's model. This can be used for identification purposes. |
1.3.6.1.4.1.232.8.2.2.6.1.11 | cpqSsBackplaneTempStatus | 0 | 0 | Storage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this st… |
1.3.6.1.4.1.232.8.2.2.6.1.12 | cpqSsBackplaneFtpsStatus | 0 | 0 | Compaq Storage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant powe… |
1.3.6.1.4.1.232.8.2.2.6.1.13 | cpqSsBackplaneSerialNumber | 0 | 0 | Storage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the fro… |
1.3.6.1.4.1.232.8.2.2.6.1.14 | cpqSsBackplanePlacement | 0 | 0 | Storage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage sy… |
1.3.6.1.4.1.232.8.2.2.6.1.15 | cpqSsBackplaneBoardRevision | 0 | 0 | Storage System Backplane Board Revision. This is the board revision of this storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.16 | cpqSsBackplaneSpeed | 0 | 0 | Storage System Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed fo… |
1.3.6.1.4.1.232.8.2.2.6.1.17 | cpqSsBackplaneConnectionType | 0 | 0 | Backlane Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection t… |
1.3.6.1.4.1.232.8.2.2.6.1.18 | cpqSsBackplaneConnector | 0 | 0 | Backplane Connector. This is the connector to which the backplane is attached. If the backplane connector cannot be determined, t… |
1.3.6.1.4.1.232.8.2.2.6.1.19 | cpqSsBackplaneOnConnector | 0 | 0 | Backplane on Connector. The backplane on connector indicates to which backplane instance this table entry belongs. The instances… |
1.3.6.1.4.1.232.8.2.2.6.1.20 | cpqSsBackplaneLocationString | 0 | 0 | Backplane Location String. This string describes the location of the backplane in relation to the controller to which it is attac… |