Compaq Storage System Backplane Fault Tolerant Power Supply
Status.
This value specifies the overall status of the redundant power
supply in a drive box. This value will be one of the following:
other(1)
The agent is unable to determine if this storage system has
redundant power supplies.
noFltTolPower(2)
This unit does not have a redundant supply.
ok(3)
There are no detected power supply failures.
degraded(4)
One of the power supply units has failed.
failed(5)
All of the power supplies have failed. A status of failed can
not currently be determined.
notSupported(6)
The storage system does not support reporting fault tolerant
power supply status through this backplane. The fault tolerant
power supply status is reported through the first backplane on
this storage system.
Parsed from file CPQSTSYS2.MIB.txt
Company: None
Module: CPQSTSYS-MIB
Storage System Backplane Fault Tolerant Power Supply Status.
This value specifies the overall status of the redundant power
supply in a drive box. This value will be one of the following:
other(1)
The agent is unable to determine if this storage system has
redundant power supplies.
noFltTolPower(2)
This unit does not have a redundant supply.
ok(3)
There are no detected power supply failures.
degraded(4)
One of the power supply units has failed.
failed(5)
All of the power supplies have failed. A status of failed can
not currently be determined.
notSupported(6)
The storage system does not support reporting fault tolerant
power supply status through this backplane. The fault tolerant
power supply status is reported through the first backplane on
this storage system.
noFltTolPower-Bay1Missing(7),
This unit does not have a redundant supply. The power supply
in bay 1 is missing.
noFltTolPower-Bay2Missing(8)
This unit does not have a redundant supply. The power supply
in bay 2 is missing.
Parsed from file CPQSTSYS-MIB.mib
Module: CPQSTSYS-MIB
cpqSsBackplaneFtpsStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noFltTolPower(2), ok(3), degraded(4), failed(5), notSupported(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Storage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value will be one of the following: other(1) The agent is unable to determine if this storage system has redundant power supplies. noFltTolPower(2) This unit does not have a redundant supply. ok(3) There are no detected power supply failures. degraded(4) One of the power supply units has failed. failed(5) All of the power supplies have failed. A status of failed can not currently be determined. notSupported(6) The storage system does not support reporting fault tolerant power supply status through this backplane. The fault tolerant power supply status is reported through the first backplane on this storage system." ::= { cpqSsBackplaneEntry 12 }
Vendor: Compaq
Module: CPQSTSYS-MIB
[Automatically extracted from oidview.com]
cpqSsBackplaneFtpsStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noFltTolPower(2), ok(3), degraded(4), failed(5), notSupported(6), noFltTolPower-Bay1Missing(7), noFltTolPower-Bay2Missing(8) } ACCESS read-only STATUS mandatory DESCRIPTION "Storage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value will be one of the following: other(1) The agent is unable to determine if this storage system has redundant power supplies. noFltTolPower(2) This unit does not have a redundant supply. ok(3) There are no detected power supply failures. degraded(4) One of the power supply units has failed. failed(5) All of the power supplies have failed. A status of failed can not currently be determined. notSupported(6) The storage system does not support reporting fault tolerant power supply status through this backplane. The fault tolerant power supply status is reported through the first backplane on this storage system. noFltTolPower-Bay1Missing(7), This unit does not have a redundant supply. The power supply in bay 1 is missing. noFltTolPower-Bay2Missing(8) This unit does not have a redundant supply. The power supply in bay 2 is missing." ::= { cpqSsBackplaneEntry 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.8.2.2.6.1.1 | cpqSsBackplaneChassisIndex | 0 | 0 | Storage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis. |
1.3.6.1.4.1.232.8.2.2.6.1.2 | cpqSsBackplaneIndex | 0 | 0 | Storage System Backplane Index. This index uniquely identifies a storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.3 | cpqSsBackplaneFWRev | 0 | 0 | Storage System Backplane Firmware Revision. This is the revision level of storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.4 | cpqSsBackplaneDriveBays | 0 | 0 | Storage System Backplane Drive Bays. This is the number of bays on this storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.5 | cpqSsBackplaneDuplexOption | 0 | 0 | Storage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this stora… |
1.3.6.1.4.1.232.8.2.2.6.1.6 | cpqSsBackplaneCondition | 0 | 0 | Storage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The … |
1.3.6.1.4.1.232.8.2.2.6.1.7 | cpqSsBackplaneVersion | 0 | 0 | Storage System Backplane Version. This is the version of the drive box back plane. |
1.3.6.1.4.1.232.8.2.2.6.1.8 | cpqSsBackplaneVendor | 0 | 0 | Storage System Backplane Vendor This is the storage box's vendor name. This can be used for identification purposes. |
1.3.6.1.4.1.232.8.2.2.6.1.9 | cpqSsBackplaneModel | 0 | 0 | Storage System Backplane Model. This is a description of the storage system's model. This can be used for identification purposes. |
1.3.6.1.4.1.232.8.2.2.6.1.10 | cpqSsBackplaneFanStatus | 0 | 0 | Compaq Storage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one … |
1.3.6.1.4.1.232.8.2.2.6.1.11 | cpqSsBackplaneTempStatus | 0 | 0 | Storage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this st… |
1.3.6.1.4.1.232.8.2.2.6.1.13 | cpqSsBackplaneSerialNumber | 0 | 0 | Storage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the fro… |
1.3.6.1.4.1.232.8.2.2.6.1.14 | cpqSsBackplanePlacement | 0 | 0 | Storage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage sy… |
1.3.6.1.4.1.232.8.2.2.6.1.15 | cpqSsBackplaneBoardRevision | 0 | 0 | Storage System Backplane Board Revision. This is the board revision of this storage system backplane. |
1.3.6.1.4.1.232.8.2.2.6.1.16 | cpqSsBackplaneSpeed | 0 | 0 | Storage System Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed fo… |
1.3.6.1.4.1.232.8.2.2.6.1.17 | cpqSsBackplaneConnectionType | 0 | 0 | Backlane Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection t… |
1.3.6.1.4.1.232.8.2.2.6.1.18 | cpqSsBackplaneConnector | 0 | 0 | Backplane Connector. This is the connector to which the backplane is attached. If the backplane connector cannot be determined, t… |
1.3.6.1.4.1.232.8.2.2.6.1.19 | cpqSsBackplaneOnConnector | 0 | 0 | Backplane on Connector. The backplane on connector indicates to which backplane instance this table entry belongs. The instances… |
1.3.6.1.4.1.232.8.2.2.6.1.20 | cpqSsBackplaneLocationString | 0 | 0 | Backplane Location String. This string describes the location of the backplane in relation to the controller to which it is attac… |