Reference record for OID 1.3.6.1.4.1.285.5.1


parent
1.3.6.1.4.1.285.5 (control)
node code
1
node name
controlRestart
dot oid
1.3.6.1.4.1.285.5.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) olicom(285) control(5) controlRestart(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) olicom(285) control(5) controlRestart(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) olicom(285) control(5) controlRestart(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) olicom(285) control(5) controlRestart(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) olicom(285) control(5) controlRestart(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) olicom(285) control(5) controlRestart(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/olicom/control/controlRestart
  • /iso/identified-organization/dod/internet/private/enterprises/olicom/control/controlRestart
  • /iso/org/dod/internet/private/enterprise/olicom/control/controlRestart
  • /iso/org/dod/internet/private/enterprises/olicom/control/controlRestart
  • /iso/iso-identified-organization/dod/internet/private/enterprise/olicom/control/controlRestart
  • /iso/iso-identified-organization/dod/internet/private/enterprises/olicom/control/controlRestart
  • Description by circitor

    Writing any value other than zero to this variable
    causes the device program to restart.

    Parsed from file Olicom-MIB.mib
    Module: Olicom-MIB

    Information by circitor

    controlRestart OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing any value other than zero to this variable causes the device program to restart." ::= { control 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.285)

    Povlsen Lars

    Brothers (20)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.285.5.2 controlConfigChangeCounter 0 0 This variable contains the number of times, any part of
    the configuration has been changed by any of the management
    systems contr…
    1.3.6.1.4.1.285.5.3 controlTrapTable 1 6 This table contains an entry for each enterprise-specific
    TRAP this device is capable of sending.
    The only writable field in the …
    1.3.6.1.4.1.285.5.4 controlLoadProtocol 0 0 This variable defines which protocol should be used for
    downloading configuration and program code.
    Notice that a specific Olicom…
    1.3.6.1.4.1.285.5.5 controlLoadFilename 0 0 In the Load protocols where it is relevant this variable
    contains the name of the file to be downloaded.
    1.3.6.1.4.1.285.5.6 controlLoadServerMACAddress 0 0 This object specifies the MAC address of the Load server
    used for download. Only used if the Load protocol defined
    by the control…
    1.3.6.1.4.1.285.5.7 controlLoadServerIPAddress 0 0 This object specifies the IP address of the Load server
    used for download. Only used if the Load protocol defined
    by the controlL…
    1.3.6.1.4.1.285.5.8 controlLoadServerIPXAddress 0 0 This object specifies the IPX address of the Load server
    used for download. Only used if the Load protocol defined
    by the control…
    1.3.6.1.4.1.285.5.9 controlLoadStart 0 0 Writing any value other than zero to this variable
    causes a download to start.
    While reading, it returns the current status of tr…
    1.3.6.1.4.1.285.5.10 controlTime 0 0 The internal clock in the device. This is measured in
    seconds since 00:00:00 on 1 January 1970 (i.e. UNIX
    standard time).
    1.3.6.1.4.1.285.5.11 controlEnableRmon 0 0 This object specifies whether RMON probe is enabled or
    disabled. If the device does not support RMON only disabled
    is allowed. Se…
    1.3.6.1.4.1.285.5.12 controlAutoRestart 0 0 This object specifies whether changes to certain fundamental
    configuration parameters (as specified for the corresponding
    MIB var…
    1.3.6.1.4.1.285.5.13 controlSwAdminStatus 0 0 This object controls the state of the SW images in systems
    where more than one image is present.

    In the OC-9100 the state of each…
    1.3.6.1.4.1.285.5.15 controlFlashConfigSize 0 0 The total number of bytes in the configuration FLASH, or
    rather, in one of the two alternating sections.
    1.3.6.1.4.1.285.5.16 controlFlashConfigFree 0 0 The number of free bytes in the configuration FLASH.
    1.3.6.1.4.1.285.5.17 controlFlashConfigState 0 0 Controls the state of the FLASH configuration. The states
    are as follows:
    normal
    default - The DEFAULT button has been activated.
    c…
    1.3.6.1.4.1.285.5.18 controlDelayedRestart 0 0 Writing value n to this variable will cause device to restart
    after n seconds.
    Writing zero cancels the reboot.
    Writing new value …
    1.3.6.1.4.1.285.5.19 controlLoadProggress 0 0 Number of bytes transmitted so far.
    0 if no transmission is currently in progress.
    1.3.6.1.4.1.285.5.20 controlLoadFileSize 0 0 Length of the file being transmitted.
    0 if no transmission is currently in progress or if
    the size is unknown.
    1.3.6.1.4.1.285.5.21 controlTftpClient 3 13 None
    1.3.6.1.4.1.285.5.22 controlRestartType 0 0 The type of restart that will be performed after next reboot
    request. After any kind of reboot the value of this object should
    be…