The internal clock in the device. This is measured in
seconds since 00:00:00 on 1 January 1970 (i.e. UNIX
standard time).
Parsed from file Olicom-MIB.mib
Module: Olicom-MIB
controlTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The internal clock in the device. This is measured in seconds since 00:00:00 on 1 January 1970 (i.e. UNIX standard time)." ::= { control 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.285.5.1 | controlRestart | 0 | 0 | Writing any value other than zero to this variable causes the device program to restart. |
1.3.6.1.4.1.285.5.2 | controlConfigChangeCounter | 0 | 0 | This variable contains the number of times, any part of the configuration has been changed by any of the management systems contr… |
1.3.6.1.4.1.285.5.3 | controlTrapTable | 1 | 6 | This table contains an entry for each enterprise-specific TRAP this device is capable of sending. The only writable field in the … |
1.3.6.1.4.1.285.5.4 | controlLoadProtocol | 0 | 0 | This variable defines which protocol should be used for downloading configuration and program code. Notice that a specific Olicom… |
1.3.6.1.4.1.285.5.5 | controlLoadFilename | 0 | 0 | In the Load protocols where it is relevant this variable contains the name of the file to be downloaded. |
1.3.6.1.4.1.285.5.6 | controlLoadServerMACAddress | 0 | 0 | This object specifies the MAC address of the Load server used for download. Only used if the Load protocol defined by the control… |
1.3.6.1.4.1.285.5.7 | controlLoadServerIPAddress | 0 | 0 | This object specifies the IP address of the Load server used for download. Only used if the Load protocol defined by the controlL… |
1.3.6.1.4.1.285.5.8 | controlLoadServerIPXAddress | 0 | 0 | This object specifies the IPX address of the Load server used for download. Only used if the Load protocol defined by the control… |
1.3.6.1.4.1.285.5.9 | controlLoadStart | 0 | 0 | Writing any value other than zero to this variable causes a download to start. While reading, it returns the current status of tr… |
1.3.6.1.4.1.285.5.11 | controlEnableRmon | 0 | 0 | This object specifies whether RMON probe is enabled or disabled. If the device does not support RMON only disabled is allowed. Se… |
1.3.6.1.4.1.285.5.12 | controlAutoRestart | 0 | 0 | This object specifies whether changes to certain fundamental configuration parameters (as specified for the corresponding MIB var… |
1.3.6.1.4.1.285.5.13 | controlSwAdminStatus | 0 | 0 | This object controls the state of the SW images in systems where more than one image is present. In the OC-9100 the state of each… |
1.3.6.1.4.1.285.5.15 | controlFlashConfigSize | 0 | 0 | The total number of bytes in the configuration FLASH, or rather, in one of the two alternating sections. |
1.3.6.1.4.1.285.5.16 | controlFlashConfigFree | 0 | 0 | The number of free bytes in the configuration FLASH. |
1.3.6.1.4.1.285.5.17 | controlFlashConfigState | 0 | 0 | Controls the state of the FLASH configuration. The states are as follows: normal default - The DEFAULT button has been activated. c… |
1.3.6.1.4.1.285.5.18 | controlDelayedRestart | 0 | 0 | Writing value n to this variable will cause device to restart after n seconds. Writing zero cancels the reboot. Writing new value … |
1.3.6.1.4.1.285.5.19 | controlLoadProggress | 0 | 0 | Number of bytes transmitted so far. 0 if no transmission is currently in progress. |
1.3.6.1.4.1.285.5.20 | controlLoadFileSize | 0 | 0 | Length of the file being transmitted. 0 if no transmission is currently in progress or if the size is unknown. |
1.3.6.1.4.1.285.5.21 | controlTftpClient | 3 | 13 | None |
1.3.6.1.4.1.285.5.22 | controlRestartType | 0 | 0 | The type of restart that will be performed after next reboot request. After any kind of reboot the value of this object should be… |