Numeric value used to indicate that a breaker is a part of a multi-pole breaker.
Breakers within a distribution module, with equivalent physical group numbers,
may have their handles physically tied together.
A value of 1 indicates breakers that are physically tied together as part of a
multi-pole breaker.
A value of 0 indicates a single-handle breaker that is not physically tied to
another breaker.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Numeric value used to indicate that a breaker is a part of a multi-pole breaker.
Breakers within a distribution module, with equivalent physical group numbers,
may have their handles physically tied together.
A value of 1 indicates breakers that are physically tied together as part of a
multi-pole breaker.
A value of 0 indicates a single-handle breaker that is not physically tied to
another breaker.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
isxModularDistModuleBreakerPhysicalGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Numeric value used to indicate that a breaker is a part of a multi-pole breaker. Breakers within a distribution module, with equivalent physical group numbers, may have their handles physically tied together. A value of 1 indicates breakers that are physically tied together as part of a multi-pole breaker. A value of 0 indicates a single-handle breaker that is not physically tied to another breaker." ::= { isxModularDistModuleBreakerEntry 5 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
isxModularDistModuleBreakerPhysicalGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Numeric value used to indicate that a breaker is a part of a multi-pole breaker. Breakers within a distribution module, with equivalent physical group numbers, may have their handles physically tied together. A value of 1 indicates breakers that are physically tied together as part of a multi-pole breaker. A value of 0 indicates a single-handle breaker that is not physically tied to another breaker." ::= { isxModularDistModuleBreakerEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.22.2.4.1.1 | isxModularDistModuleBreakerModIndex | 0 | 0 | The distribution module number. |
1.3.6.1.4.1.318.1.1.22.2.4.1.2 | isxModularDistModuleBreakerPhaseIndex | 0 | 0 | The index to an individual breaker in the distribution module. The index also corresponds to the system phase to which the brea… |
1.3.6.1.4.1.318.1.1.22.2.4.1.3 | isxModularDistModuleBreakerAlarmStatus | 0 | 0 | This is a bit map representing the active alarms for this breaker: b0 - Minimum current threshold exceeded (critical) b1 - Low cu… |
1.3.6.1.4.1.318.1.1.22.2.4.1.4 | isxModularDistModuleBreakerRating | 0 | 0 | The current rating of the breaker. |
1.3.6.1.4.1.318.1.1.22.2.4.1.6 | isxModularDistModuleBreakerCableNum | 0 | 0 | Numeric value used to indicate the distribution cable to which this breaker is connected. These distribution cables are describe… |
1.3.6.1.4.1.318.1.1.22.2.4.1.7 | isxModularDistModuleBreakerPosition | 0 | 0 | The physical status of this breaker pole, either closed or open (including tripped). |
1.3.6.1.4.1.318.1.1.22.2.4.1.8 | isxModularDistModuleBreakerPositionAlarms | 0 | 0 | Enable or disable breaker position alarms for this circuit breaker. |
1.3.6.1.4.1.318.1.1.22.2.4.1.9 | isxModularDistModuleBreakerCurrent | 0 | 0 | The current flowing though this breaker. Measured in tenths of amps. |
1.3.6.1.4.1.318.1.1.22.2.4.1.10 | isxModularDistModuleBreakerPercent | 0 | 0 | The loading on this breaker as a percentage of the breaker's current rating. Expressed in tenths of percent. |
1.3.6.1.4.1.318.1.1.22.2.4.1.11 | isxModularDistModuleBreakerPower | 0 | 0 | The power being supplied through this breaker. Measured in tenths of kW. |