Setting this OID to reset (2) will cause the all outlet energy meter values
to be reset to zero.
Getting this OID will do nothing and return the noOperation(1) value.
Models that do not support this feature will respond to this OID
with a value of notSupported (3). Attempts to set this OID
in these models will fail.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Setting this OID to reset (2) will cause the all outlet energy meter values
to be reset to zero.
Getting this OID will do nothing and return the noOperation(1) value.
Models that do not support this feature will respond to this OID
with a value of notSupported (3). Attempts to set this OID
in these models will fail.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
rPDU2DeviceConfigOutletsEnergyReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this OID to reset (2) will cause the all outlet energy meter values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail." ::= { rPDU2DeviceConfigEntry 12 }
Vendor: APC
Module: PowerNet-MIB (powernet401.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
rPDU2DeviceConfigOutletsEnergyReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this OID to reset (2) will cause the all outlet energy meter values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail." ::= { rPDU2DeviceConfigEntry 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.26.4.1.1.1 | rPDU2DeviceConfigIndex | 0 | 0 | The index to the Rack PDU table entry |
1.3.6.1.4.1.318.1.1.26.4.1.1.2 | rPDU2DeviceConfigModule | 0 | 0 | The user-defined Rack PDU numeric ID |
1.3.6.1.4.1.318.1.1.26.4.1.1.3 | rPDU2DeviceConfigName | 0 | 0 | A user-defined string identifying the Rack PDU |
1.3.6.1.4.1.318.1.1.26.4.1.1.4 | rPDU2DeviceConfigLocation | 0 | 0 | A user-defined string identifying the location of the Rack PDU |
1.3.6.1.4.1.318.1.1.26.4.1.1.5 | rPDU2DeviceConfigDisplayOrientation | 0 | 0 | Indicates the intended physical orientation of the seven segment display displayNormal(1) indicates normal orientation displayRev… |
1.3.6.1.4.1.318.1.1.26.4.1.1.6 | rPDU2DeviceConfigColdstartDelay | 0 | 0 | The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic mas… |
1.3.6.1.4.1.318.1.1.26.4.1.1.7 | rPDU2DeviceConfigLowLoadPowerThreshold | 0 | 0 | User-defined low power draw alarm threshold, measured in tenths of kilowatts |
1.3.6.1.4.1.318.1.1.26.4.1.1.8 | rPDU2DeviceConfigNearOverloadPowerThreshold | 0 | 0 | User-defined near power overload threshold, measured in tenths of kilowatts |
1.3.6.1.4.1.318.1.1.26.4.1.1.9 | rPDU2DeviceConfigOverloadPowerThreshold | 0 | 0 | User-defined power overload threshold, measured in tenths of kilowatts |
1.3.6.1.4.1.318.1.1.26.4.1.1.10 | rPDU2DeviceConfigDevicePeakPowerReset | 0 | 0 | Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting th… |
1.3.6.1.4.1.318.1.1.26.4.1.1.11 | rPDU2DeviceConfigDeviceEnergyReset | 0 | 0 | Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this OID in models that suppo… |