The minimum output current in 0.1 amperes measured
since the last time this variable was read
or reset (atsStatusResetMaxMinValues).
Returns (-1) if unsupported.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The minimum output current in 0.1 amperes measured
since the last time this variable was read
or reset (atsStatusResetMaxMinValues).
Returns (-1) if unsupported.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
atsOutputMinCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported." ::= { atsOutputPhaseEntry 6 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
atsOutputMinCurrent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported." ::= { atsOutputPhaseEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.8.5.4.3.1.1 | atsOutputPhaseTableIndex | 0 | 0 | The output identifier. |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.2 | atsOutputPhaseIndex | 0 | 0 | Description of each output phase utilized in this device and one for neutral. |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.3 | atsOutputVoltage | 0 | 0 | The output voltage in VAC, or -1 if it's unsupported by this ATS. |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.4 | atsOutputCurrent | 0 | 0 | The output current in 0.1 amperes drawn by the load on the ATS, or -1 if it's unsupported by this ATS. |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.5 | atsOutputMaxCurrent | 0 | 0 | The maximum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValue… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.7 | atsOutputLoad | 0 | 0 | The output load in VA, or -1 if it's unsupported by this ATS. |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.8 | atsOutputMaxLoad | 0 | 0 | The maximum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.9 | atsOutputMinLoad | 0 | 0 | The minimum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.10 | atsOutputPercentLoad | 0 | 0 | The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's un… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.11 | atsOutputMaxPercentLoad | 0 | 0 | The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase … |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.12 | atsOutputMinPercentLoad | 0 | 0 | The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase … |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.13 | atsOutputPower | 0 | 0 | The output power in Watts, or -1 if it's unsupported by this ATS. |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.14 | atsOutputMaxPower | 0 | 0 | The maximum output power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Retur… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.15 | atsOutputMinPower | 0 | 0 | The minimum output power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Retur… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.16 | atsOutputPercentPower | 0 | 0 | The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.17 | atsOutputMaxPercentPower | 0 | 0 | The maximum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this output pha… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.18 | atsOutputMinPercentPower | 0 | 0 | The minimum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this output pha… |
1.3.6.1.4.1.318.1.1.8.5.4.3.1.19 | atsOutputPhaseState | 0 | 0 | Getting this OID will return the phase load state. normal(1) indicates that the bank is operating properly within the atsConfigP… |