The output voltage in VAC, or -1 if it's unsupported
by this ATS.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The output voltage in VAC, or -1 if it's unsupported
by this ATS.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
atsOutputBankOutputVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output voltage in VAC, or -1 if it's unsupported by this ATS." ::= { atsOutputBankEntry 6 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
atsOutputBankOutputVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output voltage in VAC, or -1 if it's unsupported by this ATS." ::= { atsOutputBankEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.8.5.4.5.1.1 | atsOutputBankTableIndex | 0 | 0 | The index to the bank table entry. |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.2 | atsOutputPhase | 0 | 0 | The phase number of an ATS |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.3 | atsOutputBank | 0 | 0 | The bank number of an ATS |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.4 | atsOutputBankCurrent | 0 | 0 | Getting this OID will return the bank current measured in tenths of Amps. |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.5 | atsOutputBankState | 0 | 0 | Getting this OID will return the bank load state. normal(1) indicates that the bank is operating properly within the atsConfigBa… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.7 | atsOutputBankMaxCurrent | 0 | 0 | The maximum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variab… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.8 | atsOutputBankMinCurrent | 0 | 0 | The minimum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variab… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.9 | atsOutputBankLoad | 0 | 0 | The output load, on the bank represented by OID atsOutputBank, in VA, or -1 if it's unsupported by this ATS. |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.10 | atsOutputBankMaxLoad | 0 | 0 | The maximum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read o… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.11 | atsOutputBankMinLoad | 0 | 0 | The minimum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read o… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.12 | atsOutputBankPercentLoad | 0 | 0 | The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this bank, represented by OID atsOu… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.13 | atsOutputBankMaxPercentLoad | 0 | 0 | The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represe… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.14 | atsOutputBankMinPercentLoad | 0 | 0 | The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represe… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.15 | atsOutputBankPower | 0 | 0 | The output power in Watts on the bank represented by OID atsOutputBank or -1 if it's unsupported by this ATS. |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.16 | atsOutputBankMaxPower | 0 | 0 | The maximum output power in Watts measured on the bank represented by OID atsOutputBank since the last time this variable was rea… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.17 | atsOutputBankMinPower | 0 | 0 | The minimum output power in Watts measured on the bank represented by OID atsOutputBank since the last time this variable was rea… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.18 | atsOutputBankPercentPower | 0 | 0 | The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this bank, represented by OID at… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.19 | atsOutputBankMaxPercentPower | 0 | 0 | The maximum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this bank, repr… |
1.3.6.1.4.1.318.1.1.8.5.4.5.1.20 | atsOutputBankMinPercentPower | 0 | 0 | The minimum percentage of the ATSpower capacity in Watts measured at redundancy @ (n + x) presently being used on this bank, repr… |