A correction gain associated with the sensor variable.
The value of gain is multiplied by the value from
Input Sensor Number 2 to obtain the value of
the Input2 variable. The gain variable is stored in
non-volatile memory.
Parsed from file Falconmib.txt
Company: None
Module: RLE-FALCON-MIB
A correction gain associated with the sensor variable.
The value of gain is multiplied by the value from
Input Sensor Number 2 to obtain the value of
the Input2 variable. The gain variable is stored in
non-volatile memory.
Parsed from file RLE-FALCON-MIB.mib
Module: RLE-FALCON-MIB
Vendor: Raymond and Lae Engineering, Inc.
Module: RLE-FALCON-MIB
[Automatically extracted from oidview.com]
FalconInput2Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 2 to obtain the value of the Input2 variable. The gain variable is stored in non-volatile memory." ::= { FalconInput2 3 }
falconInput2Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 2 to obtain the value of the Input2 variable. The gain variable is stored in non-volatile memory." ::= { falconInput2 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3184.1.1.1.3.2.3.0 | 0 | 0 | 0 | FalconInput2Gain |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3184.1.1.1.3.2.1 | FalconInput2State | 1 | 1 | The state of use of Input Number 2. When a sensor is connected to Input 2 set State to installed(2) to indicate that the value of… |
1.3.6.1.4.1.3184.1.1.1.3.2.2 | FalconInput2Reading | 1 | 1 | The reading for sensor 2. If the input is digital, the reading will be 1 (active) or 0 (inactive) |
1.3.6.1.4.1.3184.1.1.1.3.2.4 | FalconInput2Offset | 1 | 1 | A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 2 to … |
1.3.6.1.4.1.3184.1.1.1.3.2.5 | FalconInput2Label | 1 | 1 | A user-defined text string associated with Input Number 2. The text string is stored in non-volatile memory. |
1.3.6.1.4.1.3184.1.1.1.3.2.6 | FalconInput2UOM | 1 | 1 | A user-defined text string associated with Input Number 2. The text string is stored in non-volatile memory. |
1.3.6.1.4.1.3184.1.1.1.3.2.7 | FalconInput2HighLimit2 | 1 | 1 | When input 2 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 2. The HighLimit v… |
1.3.6.1.4.1.3184.1.1.1.3.2.8 | FalconInput2HighLimit | 1 | 1 | When input 2 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 2. The HighLimit v… |
1.3.6.1.4.1.3184.1.1.1.3.2.9 | FalconInput2LowLimit | 1 | 1 | When input 2 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 2. The LowLimit… |
1.3.6.1.4.1.3184.1.1.1.3.2.10 | FalconInput2LowLimit2 | 1 | 1 | When input 2 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 2. The LowLimit… |
1.3.6.1.4.1.3184.1.1.1.3.2.11 | FalconInput2RlyControl | 1 | 1 | The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, … |
1.3.6.1.4.1.3184.1.1.1.3.2.12 | FalconInput2Delay | 1 | 1 | The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This varia… |
1.3.6.1.4.1.3184.1.1.1.3.2.13 | FalconInput2Hysteresis | 1 | 1 | The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will cle… |