The notification indicates that the Virtual Circuit has
changed state. It has either been created or invalidated,
or has toggled between the active and inactive states.
If the reason for the state change is due to the DLCMI
going down, the trap should not be generated.
frDCLIStatusChange trap defined in RFC 2115 will also be
generated when this event occurs.
Parsed from file SSG-5000-CHASSIS-MIB.my.txt
Company: nortel
Module: SSG-5000-CHASSIS-MIB
ssg5000FrameRelayAlarmNotification NOTIFICATION-TYPE OBJECTS { ssg5000TrapFrameRelayAlarmId, ssg5000TrapSlotId, ssg5000TrapCardType, ssg5000TrapPortId, ssg5000TrapDS1ChannelId, ssg5000TrapOccurClearTag, ssg5000TrapDLCINumber, ssg5000TrapConnectionName, ssg5000TrapSSGHostAddress } STATUS current DESCRIPTION "The notification indicates that the Virtual Circuit has changed state. It has either been created or invalidated, or has toggled between the active and inactive states. If the reason for the state change is due to the DLCMI going down, the trap should not be generated. frDCLIStatusChange trap defined in RFC 2115 will also be generated when this event occurs." ::= { ssg5000MIBNotification 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3199.10.28.2.0.1 | ssg5000ChassisFailureNotification | 0 | 0 | The notification signifies that the agent detects a change in the status of ps1, ps2, fan, chassis temperature. |
1.3.6.1.4.1.3199.10.28.2.0.2 | ssg5000SysAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the system. |
1.3.6.1.4.1.3199.10.28.2.0.3 | ssg5000CardAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the card. |
1.3.6.1.4.1.3199.10.28.2.0.4 | ssg5000PortAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the port. |
1.3.6.1.4.1.3199.10.28.2.0.5 | ssg5000SSMAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the SSM. |
1.3.6.1.4.1.3199.10.28.2.0.6 | ssg5000PVCAlarmNotification | 0 | 0 | The notification signifies that the agent detects an alarm status in a PVC. |
1.3.6.1.4.1.3199.10.28.2.0.7 | ssg5000CT3PortAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the CT3 port. |
1.3.6.1.4.1.3199.10.28.2.0.8 | ssg5000ETHPortAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the ETHERNET port. |
1.3.6.1.4.1.3199.10.28.2.0.9 | ssg5000CT3DS2AlarmNotification | 0 | 0 | The notification signal the agent detects a DS2 alarm status in the CT3 port. |
1.3.6.1.4.1.3199.10.28.2.0.10 | ssg5000CT3DS1AlarmNotification | 0 | 0 | The notification signal the agent detects a DS1 alarm status in the CT3 port. |
1.3.6.1.4.1.3199.10.28.2.0.11 | ssg5000ServiceAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm in SSG Service related modules. |