The notification signal the agent detects an alarm status
in the system.
Parsed from file SSG-5000-CHASSIS-MIB.my.txt
Company: None
Module: SSG-5000-CHASSIS-MIB
The notification signal the agenet detects an alarm status
in the system.
Parsed from file SSG-5000-CHASSIS-MIB.mib
Module: SSG-5000-CHASSIS-MIB
Vendor: Shasta Networks
Module: SSG-5000-CHASSIS-MIB
[Automatically extracted from oidview.com]
ssg5000SysAlarmNotification NOTIFICATION-TYPE OBJECTS { ssg5000TrapSystemAlarmId, ssg5000TrapOccurClearTag, ssg5000TrapSSGHostAddress } STATUS current DESCRIPTION "The notification signal the agent detects an alarm status in the system." ::= { ssg5000MIBNotification 2 }
ssg5000SysAlarmNotification NOTIFICATION-TYPE OBJECTS { ssg5000TrapSystemAlarmId, ssg5000TrapOccurClearTag, ssg5000TrapSSGHostAddress } STATUS current DESCRIPTION "The notification signal the agenet detects an alarm status in the system." ::= { ssg5000MIBNotification 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3199.10.28.2.0.1 | ssg5000ChassisFailureNotification | 0 | 0 | The notification signifies that the agent detects a change in the status of ps1, ps2, fan, chassis temperature. |
1.3.6.1.4.1.3199.10.28.2.0.3 | ssg5000CardAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the card. |
1.3.6.1.4.1.3199.10.28.2.0.4 | ssg5000PortAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the port. |
1.3.6.1.4.1.3199.10.28.2.0.5 | ssg5000SSMAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the SSM. |
1.3.6.1.4.1.3199.10.28.2.0.6 | ssg5000PVCAlarmNotification | 0 | 0 | The notification signifies that the agent detects an alarm status in a PVC. |
1.3.6.1.4.1.3199.10.28.2.0.7 | ssg5000CT3PortAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the CT3 port. |
1.3.6.1.4.1.3199.10.28.2.0.8 | ssg5000ETHPortAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm status in the ETHERNET port. |
1.3.6.1.4.1.3199.10.28.2.0.9 | ssg5000CT3DS2AlarmNotification | 0 | 0 | The notification signal the agent detects a DS2 alarm status in the CT3 port. |
1.3.6.1.4.1.3199.10.28.2.0.10 | ssg5000CT3DS1AlarmNotification | 0 | 0 | The notification signal the agent detects a DS1 alarm status in the CT3 port. |
1.3.6.1.4.1.3199.10.28.2.0.11 | ssg5000ServiceAlarmNotification | 0 | 0 | The notification signal the agent detects an alarm in SSG Service related modules. |
1.3.6.1.4.1.3199.10.28.2.0.12 | ssg5000FrameRelayAlarmNotification | 0 | 0 | The notification indicates that the Virtual Circuit has changed state. It has either been created or invalidated, or has toggled … |