saRingCplConfigOperState

1.3.6.1.4.1.3833.1.1.14.5.2.1.15

Description

Operational state of the ring coupling configuration. slaveCouplingLinkError(2) indicates that the coupling link is not connected with the coupling port of the slave but with another port of the slave. In case of outband control additional failures can be detected: slaveControlLinkError(3) indicates that the control p…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.5.2.1 (saRingCouplingEntry)
Node code
15
Node name
saRingCplConfigOperState
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.1.14.5.2.1.15
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.5.2.1.15
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 5 2 1 15}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplConfigOperState(15)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/5/2/1/15
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/5/2/1/15
  • /ISO/3/6/1/4/1/3833/1/1/14/5/2/1/15
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplConfigOperState
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Enumerated values

ValueName
1noError
2slaveCouplingLinkError
3slaveControlLinkError
4masterControlLinkError
5twoSlaves
6localPartnerLinkError
7localInvalidCouplingPort
8couplingPortNotAvailable
9controlPortNotAvailable
10partnerPortNotAvailable

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In TFPRIVATE-MIB, the row index consists of these components in order:

  1. saRingCplInterconnGroupID (INTEGER): one numeric subidentifier for the non-negative value.
  2. saRingCplInterconnIfIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.3833.1.1.14.5.2.1.15.<saRingCplInterconnGroupID>.<saRingCplInterconnIfIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.5.2.1.15

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saRingCplConfigOperState OBJECT-TYPE
                 SYNTAX          INTEGER {
                                 noError(1),
                                 slaveCouplingLinkError(2),                                 
                                 slaveControlLinkError(3),
                                 masterControlLinkError(4),
                                 twoSlaves(5),
                                 localPartnerLinkError(6),
                                 localInvalidCouplingPort(7),
                                 couplingPortNotAvailable(8),
                                 controlPortNotAvailable(9),
                                 partnerPortNotAvailable(10)
                                 }
                ACCESS           read-only
                STATUS           mandatory
                DESCRIPTION      
                "Operational state of the ring coupling configuration.
                
                slaveCouplingLinkError(2) indicates that the coupling link 
		is not connected with the coupling port of the slave but with 
		another port of the slave.
 
                In case of outband control additional failures can be 
                detected:
                      slaveControlLinkError(3) indicates that the control 
                      port of the slave has either no link or the link 
                      fails.
                      masterControlLinkError(4) indicates that the control 
                      link is not connected with the control port of the 
                      master but with another port of the master.
                      twoSlaves(5) is returned when two slaves are connected                          
                      by the control line.
 
		localPartnerLinkError(6) indicates that the partner coupling link
		is not connected with the partner port of the slave but with 
		another port of the slave in local control mode.
		localInvalidCouplingPort(7) indicates that in local mode the coupling 
                line is connected to another switch and not on the same switch like
                the partner line.

                couplingPortNotAvailable(8), controlPortNotAvailable(9) and
                partnerPortNotAvailable(10) indicate that this port is not available
                because the module related to this port is not available or the port
                does not exist on this module."
                ::= { saRingCouplingEntry 15 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Operational state of the ring coupling configuration. slaveCouplingLinkError(2) indicates that the coupling link is not connected with the coupling port of the slave but with another port of the slave. In case of outband control additional failures can be detected: slaveControlLinkError(3) indicates that the control port of the slave has either no link or the link fails. masterControlLinkError(4) indicates that the control link is not connected with the control port of the master but with another port of the master. twoSlaves(5) is returned when two slaves are connected by the control line. localPartnerLinkError(6) indicates that the partner coupling link is not connected with the partner port of the slave but with another port of the slave in local control mode. localInvalidCouplingPort(7) indicates that in local mode the coupling line is connected to another switch and not on the same switch like the partner line. couplingPortNotAvailable(8), controlPortNotAvailable(9) and partnerPortNotAvailable(10) indicate that this port is not available because the module related to this port is not available or the port does not exist on this module.

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saRingCplConfigOperState · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: saRingCplConfigOperState

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saRingCplConfigOperState",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "noError",
    "(",
    "1",
    ")",
    ",",
    "slaveCouplingLinkError",
    "(",
    "2",
    ")",
    ",",
    "slaveControlLinkError",
    "(",
    "3",
    ")",
    ",",
    "masterControlLinkError",
    "(",
    "4",
    ")",
    ",",
    "twoSlaves",
    "(",
    "5",
    ")",
    ",",
    "localPartnerLinkError",
    "(",
    "6",
    ")",
    ",",
    "localInvalidCouplingPort",
    "(",
    "7",
    ")",
    ",",
    "couplingPortNotAvailable",
    "(",
    "8",
    ")",
    ",",
    "controlPortNotAvailable",
    "(",
    "9",
    ")",
    ",",
    "partnerPortNotAvailable",
    "(",
    "10",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Operational state of the ring coupling configuration. slaveCouplingLinkError(2) indicates that the coupling link is not connected with the coupling port of the slave but with another port of the slave. In case of outband control additional failures can be detected: slaveControlLinkError(3) indicates that the control port of the slave has either no link or the link fails. masterControlLinkError(4) indicates that the control link is not connected with the control port of the master but with another port of the master. twoSlaves(5) is returned when two slaves are connected by the control line. localPartnerLinkError(6) indicates that the partner coupling link is not connected with the partner port of the slave but with another port of the slave in local control mode. localInvalidCouplingPort(7) indicates that in local mode the coupling line is connected to another switch and not on the same switch like the partner line. couplingPortNotAvailable(8), controlPortNotAvailable(9) and partnerPortNotAvailable(10) indicate that this port is not available because the module related to this port is not available or the port does not exist on this module.\"",
    "::=",
    "{",
    "saRingCouplingEntry",
    "15",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "noError",
            1
          ],
          [
            "slaveCouplingLinkError",
            2
          ],
          [
            "slaveControlLinkError",
            3
          ],
          [
            "masterControlLinkError",
            4
          ],
          [
            "twoSlaves",
            5
          ],
          [
            "localPartnerLinkError",
            6
          ],
          [
            "localInvalidCouplingPort",
            7
          ],
          [
            "couplingPortNotAvailable",
            8
          ],
          [
            "controlPortNotAvailable",
            9
          ],
          [
            "partnerPortNotAvailable",
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Operational state of the ring coupling configuration. slaveCouplingLinkError(2) indicates that the coupling link is not connected with the coupling port of the slave but with another port of the slave. In case of outband control additional failures can be detected: slaveControlLinkError(3) indicates that the control port of the slave has either no link or the link fails. masterControlLinkError(4) indicates that the control link is not connected with the control port of the master but with another port of the master. twoSlaves(5) is returned when two slaves are connected by the control line. localPartnerLinkError(6) indicates that the partner coupling link is not connected with the partner port of the slave but with another port of the slave in local control mode. localInvalidCouplingPort(7) indicates that in local mode the coupling line is connected to another switch and not on the same switch like the partner line. couplingPortNotAvailable(8), controlPortNotAvailable(9) and partnerPortNotAvailable(10) indicate that this port is not available because the module related to this port is not available or the port does not exist on this module."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (17)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.5.2.1.1 saRingCplInterconnGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.2 saRingCplInterconnIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.3 saRingCplInterconnIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.4 saRingCplControlGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.5 saRingCplControlIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.6 saRingCplControlIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.7 saRingCplControlMode00
1.3.6.1.4.1.3833.1.1.14.5.2.1.8 saRingCplPartnerIpAddr00
1.3.6.1.4.1.3833.1.1.14.5.2.1.9 saRingCplPartnerInterconnGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.10 saRingCplPartnerInterconnIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.11 saRingCplPartnerInterconnIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.12 saRingCplOperState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.13 saRingCplMode00
1.3.6.1.4.1.3833.1.1.14.5.2.1.14 saRingCplRowStatus00
1.3.6.1.4.1.3833.1.1.14.5.2.1.16 saRingCplCouplingLinks00
1.3.6.1.4.1.3833.1.1.14.5.2.1.17 saRingCplExtendedDiag00
1.3.6.1.4.1.3833.1.1.14.5.2.1.18 saRingCplNetCoupling00