OID reference

saRingCplCouplingLinks

1.3.6.1.4.1.3833.1.1.14.5.2.1.16

Description

Maximum coupling links between two coupled rings or nets which will be in forwarding in case of a failure in one of the coupled rings or nets. If there is no connection starting from the switch in slave or local operational state over the route of the coupled rings or nets to oneself the slave or the local mode want t…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.5.2.1 (saRingCouplingEntry)
Node code
16
Node name
saRingCplCouplingLinks
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.1.14.5.2.1.16
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.5.2.1.16
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 5 2 1 16}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplCouplingLinks(16)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/5/2/1/16
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/5/2/1/16
  • /ISO/3/6/1/4/1/3833/1/1/14/5/2/1/16
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplCouplingLinks
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1basicRedundancy
2extendedRedundancy

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In TFPRIVATE-MIB, the row index consists of these components in order:

  1. saRingCplInterconnGroupID (INTEGER): one numeric subidentifier for the non-negative value.
  2. saRingCplInterconnIfIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.3833.1.1.14.5.2.1.16.<saRingCplInterconnGroupID>.<saRingCplInterconnIfIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.5.2.1.16

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saRingCplCouplingLinks   OBJECT-TYPE
                SYNTAX          INTEGER {
                                basicRedundancy(1),
                                extendedRedundancy(2)
                                }
                ACCESS          read-write
                STATUS          mandatory
                DESCRIPTION
                "Maximum coupling links between two coupled rings or nets which will be in 
                forwarding in case of a failure	in one of the coupled rings or nets.
 
                If there is no connection starting from the switch in slave or local 
                operational state over the route of the coupled rings or nets to oneself
                the slave or the local mode want to set the coupling port in forwarding 
                after a timeout period.
 
		basicRedundancy(1) prevents the slave or the local mode from setting its 
                coupling port into forwarding in case of the described failure. In this 
                case the segment which is connected to this coupling port is unreachable 
                until the failure is eliminated.                
 
		In extendedRedundancy(2) the coupling port and the partner coupling port
		are allowed to be in forwarding."
                ::= { saRingCouplingEntry 16 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Maximum coupling links between two coupled rings or nets which will be in forwarding in case of a failure in one of the coupled rings or nets. If there is no connection starting from the switch in slave or local operational state over the route of the coupled rings or nets to oneself the slave or the local mode want to set the coupling port in forwarding after a timeout period. basicRedundancy(1) prevents the slave or the local mode from setting its coupling port into forwarding in case of the described failure. In this case the segment which is connected to this coupling port is unreachable until the failure is eliminated. In extendedRedundancy(2) the coupling port and the partner coupling port are allowed to be in forwarding.

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saRingCplCouplingLinks · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: saRingCplCouplingLinks

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saRingCplCouplingLinks",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "basicRedundancy",
    "(",
    "1",
    ")",
    ",",
    "extendedRedundancy",
    "(",
    "2",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Maximum coupling links between two coupled rings or nets which will be in forwarding in case of a failure in one of the coupled rings or nets. If there is no connection starting from the switch in slave or local operational state over the route of the coupled rings or nets to oneself the slave or the local mode want to set the coupling port in forwarding after a timeout period. basicRedundancy(1) prevents the slave or the local mode from setting its coupling port into forwarding in case of the described failure. In this case the segment which is connected to this coupling port is unreachable until the failure is eliminated. In extendedRedundancy(2) the coupling port and the partner coupling port are allowed to be in forwarding.\"",
    "::=",
    "{",
    "saRingCouplingEntry",
    "16",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "basicRedundancy",
            1
          ],
          [
            "extendedRedundancy",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Maximum coupling links between two coupled rings or nets which will be in forwarding in case of a failure in one of the coupled rings or nets. If there is no connection starting from the switch in slave or local operational state over the route of the coupled rings or nets to oneself the slave or the local mode want to set the coupling port in forwarding after a timeout period. basicRedundancy(1) prevents the slave or the local mode from setting its coupling port into forwarding in case of the described failure. In this case the segment which is connected to this coupling port is unreachable until the failure is eliminated. In extendedRedundancy(2) the coupling port and the partner coupling port are allowed to be in forwarding."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (17)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.5.2.1.1 saRingCplInterconnGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.2 saRingCplInterconnIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.3 saRingCplInterconnIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.4 saRingCplControlGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.5 saRingCplControlIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.6 saRingCplControlIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.7 saRingCplControlMode00
1.3.6.1.4.1.3833.1.1.14.5.2.1.8 saRingCplPartnerIpAddr00
1.3.6.1.4.1.3833.1.1.14.5.2.1.9 saRingCplPartnerInterconnGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.10 saRingCplPartnerInterconnIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.11 saRingCplPartnerInterconnIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.12 saRingCplOperState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.13 saRingCplMode00
1.3.6.1.4.1.3833.1.1.14.5.2.1.14 saRingCplRowStatus00
1.3.6.1.4.1.3833.1.1.14.5.2.1.15 saRingCplConfigOperState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.17 saRingCplExtendedDiag00
1.3.6.1.4.1.3833.1.1.14.5.2.1.18 saRingCplNetCoupling00