Description

Control mode of the ring coupling which can only be chosen by the slave, the master just reports his current control mode. unknown(3) cannot be set. In outband(1) mode an additional line must connect the control interfaces between the two partners in the ring coupling. In inband(2) mode only the coupling link port is …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.1.14.5.2.1 (saRingCouplingEntry)
Node code
7
Node name
saRingCplControlMode
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.1.14.5.2.1.7
URN notation
urn:oid:1.3.6.1.4.1.3833.1.1.14.5.2.1.7
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 1 14 5 2 1 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) switch(1) saConfiguration(14) saRingRedundancy(5) saRingCouplingTable(2) saRingCouplingEntry(1) saRingCplControlMode(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/1/14/5/2/1/7
  • /ISO/Identified-Organization/6/1/4/1/3833/1/1/14/5/2/1/7
  • /ISO/3/6/1/4/1/3833/1/1/14/5/2/1/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/switch/saConfiguration/saRingRedundancy/saRingCouplingTable/saRingCouplingEntry/saRingCplControlMode
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory

Enumerated values

ValueName
1outband
2inband
3unknown
4local
5disable

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In TFPRIVATE-MIB, the row index consists of these components in order:

  1. saRingCplInterconnGroupID (INTEGER): one numeric subidentifier for the non-negative value.
  2. saRingCplInterconnIfIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.3833.1.1.14.5.2.1.7.<saRingCplInterconnGroupID>.<saRingCplInterconnIfIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.3833.1.1.14.5.2.1.7

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saRingCplControlMode OBJECT-TYPE
                SYNTAX           INTEGER {
                                 outband(1),
                                 inband(2),
                                 unknown(3),
                                 local(4),
                                 disable(5)
                                 }
                ACCESS           read-write
                STATUS           mandatory
                DESCRIPTION      
                "Control mode of the ring coupling which can only be
                chosen by the slave, the master just reports his current 
                control mode. unknown(3) cannot be set.
                In outband(1) mode an additional line must connect the control
                interfaces between the two partners in the ring coupling.
                In inband(2) mode only the coupling link port is needed.
                In local(4) mode the coupling link port and the partner port are
                located on the same switch.
                disable(5) deactivates the ring coupling functionality."
                ::= { saRingCouplingEntry 7 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Control mode of the ring coupling which can only be chosen by the slave, the master just reports his current control mode. unknown(3) cannot be set. In outband(1) mode an additional line must connect the control interfaces between the two partners in the ring coupling. In inband(2) mode only the coupling link port is needed. In local(4) mode the coupling link port and the partner port are located on the same switch. disable(5) deactivates the ring coupling functionality.

Sources for this description

Schneider Electric Transparent Factory official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric Transparent Factory official MIB1 record · 1 source

Description 1

saRingCplControlMode · mandatorySchneider Electric Transparent Factory official MIB1 source

Status in source: mandatory.

Names: saRingCplControlMode

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saRingCplControlMode",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "outband",
    "(",
    "1",
    ")",
    ",",
    "inband",
    "(",
    "2",
    ")",
    ",",
    "unknown",
    "(",
    "3",
    ")",
    ",",
    "local",
    "(",
    "4",
    ")",
    ",",
    "disable",
    "(",
    "5",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Control mode of the ring coupling which can only be chosen by the slave, the master just reports his current control mode. unknown(3) cannot be set. In outband(1) mode an additional line must connect the control interfaces between the two partners in the ring coupling. In inband(2) mode only the coupling link port is needed. In local(4) mode the coupling link port and the partner port are located on the same switch. disable(5) deactivates the ring coupling functionality.\"",
    "::=",
    "{",
    "saRingCouplingEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "outband",
            1
          ],
          [
            "inband",
            2
          ],
          [
            "unknown",
            3
          ],
          [
            "local",
            4
          ],
          [
            "disable",
            5
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Control mode of the ring coupling which can only be chosen by the slave, the master just reports his current control mode. unknown(3) cannot be set. In outband(1) mode an additional line must connect the control interfaces between the two partners in the ring coupling. In inband(2) mode only the coupling link port is needed. In local(4) mode the coupling link port and the partner port are located on the same switch. disable(5) deactivates the ring coupling functionality."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (17)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.1.14.5.2.1.1 saRingCplInterconnGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.2 saRingCplInterconnIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.3 saRingCplInterconnIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.4 saRingCplControlGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.5 saRingCplControlIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.6 saRingCplControlIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.8 saRingCplPartnerIpAddr00
1.3.6.1.4.1.3833.1.1.14.5.2.1.9 saRingCplPartnerInterconnGroupID00
1.3.6.1.4.1.3833.1.1.14.5.2.1.10 saRingCplPartnerInterconnIfIndex00
1.3.6.1.4.1.3833.1.1.14.5.2.1.11 saRingCplPartnerInterconnIfOpState00
1.3.6.1.4.1.3833.1.1.14.5.2.1.12 saRingCplOperState00