DEPRECATED, use seHdpmSystemPtRatio instead. Voltage scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of Volts returned for circuits and channels will be in units of tenths of volts multiplied by this value so a value of 100 means tens of volts.
OID reference
seHdpmSystemVoltsScale
1.3.6.1.4.1.3833.1.6000.1.1.7
Description
DEPRECATED, use seHdpmSystemPtRatio instead. Voltage scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of Volts returned for circuits and channels will be in units of tenths of volts multiplied by this value so a value of 100 means tens of volts.
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.3833.1.6000.1.1 (seHdpmSystem)
- Node code
- 7
- Node name
- seHdpmSystemVoltsScale
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.3833.1.6000.1.1.7
- URN notation
- urn:oid:1.3.6.1.4.1.3833.1.6000.1.1.7
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 3833 1 6000 1 1 7}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemVoltsScale(7)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/3833/1/6000/1/1/7
- /ISO/Identified-Organization/6/1/4/1/3833/1/6000/1/1/7
- /ISO/3/6/1/4/1/3833/1/6000/1/1/7
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemVoltsScale
- Additional combinations skipped.
SNMP properties
- Value type
- INTEGER
- Maximum access defined by MIB
- read-only
- Status in MIB
- current
Enumerated values
| Value | Name |
|---|---|
| 1 | voltTenths |
| 10 | volt |
| 100 | voltTens |
| 1000 | voltHundreds |
| 10000 | voltThousands |
Using this OID with SNMP
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.3833.1.6000.1.1.7.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
Documented MIB packages
This OID is defined in a Schneider Electric HDPM6000 MIB distributed with these firmware packages:
- Firmware 0.62.11 · Download firmware package · Download MIB
- Firmware 0.64.2 · Download firmware package · Download MIB
- Firmware 0.66.0 · Download firmware package · Download MIB
A definition in a firmware package does not establish that every device implements it or permits access. Other firmware versions have not been verified here.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
seHdpmSystemVoltsScale OBJECT-TYPE
SYNTAX INTEGER { voltTenths(1), volt(10), voltTens(100), voltHundreds(1000), voltThousands(10000) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DEPRECATED, use seHdpmSystemPtRatio instead. Voltage scale factor where possible
values are: 1, 10, 100, 1000, or 10000. The value of Volts returned for circuits
and channels will be in units of tenths of volts multiplied by this value so a
value of 100 means tens of volts. "
::= { seHdpmSystem 7 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1Schneider Electric HDPM6000 official MIB
seHdpmSystemVoltsScale · currentSchneider Electric HDPM6000 official MIB
Status in source: current.
Names: seHdpmSystemVoltsScale
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"seHdpmSystemVoltsScale",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"voltTenths",
"(",
"1",
")",
",",
"volt",
"(",
"10",
")",
",",
"voltTens",
"(",
"100",
")",
",",
"voltHundreds",
"(",
"1000",
")",
",",
"voltThousands",
"(",
"10000",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"DEPRECATED, use seHdpmSystemPtRatio instead. Voltage scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of Volts returned for circuits and channels will be in units of tenths of volts multiplied by this value so a value of 100 means tens of volts. \"",
"::=",
"{",
"seHdpmSystem",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"voltTenths",
1
],
[
"volt",
10
],
[
"voltTens",
100
],
[
"voltHundreds",
1000
],
[
"voltThousands",
10000
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"DEPRECATED, use seHdpmSystemPtRatio instead. Voltage scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of Volts returned for circuits and channels will be in units of tenths of volts multiplied by this value so a value of 100 means tens of volts."
],
null,
null,
null,
null
]
}- Schneider Electric HDPM6000 official MIB
· Publisher's source file: Schneider Electric HDPM6000 MIB — firmware 0.62.11, 0.64.2
Module: SCHNEIDER-ELECTRIC-HDPM
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Gauge32', 'Integer32', 'Unsigned32', 'Counter64', 'Counter32'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Source data warning: Original Schneider Electric HDPM6000 MIB from firmware bundle version(s) 0.62.11, 0.64.2. Applicability to other firmware versions has not been independently confirmed.
· Download Schneider Electric HDPM6000 MIB — firmware 0.62.11, 0.64.2Related source files and packages:
- Schneider Electric HDPM6000 official MIB
· Publisher's source file: Schneider Electric HDPM6000 MIB — firmware 0.66.0
Module: SCHNEIDER-ELECTRIC-HDPM
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'Gauge32', 'Integer32', 'Unsigned32', 'Counter64', 'Counter32'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Source data warning: Original Schneider Electric HDPM6000 MIB from firmware bundle version(s) 0.66.0. Applicability to other firmware versions has not been independently confirmed.
· Download Schneider Electric HDPM6000 MIB — firmware 0.66.0Related source files and packages:
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)
Siblings (15)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3833.1.6000.1.1.1 | seHdpmSystemChannelCount | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.2 | seHdpmSystemFirmwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.3 | seHdpmSystemMicroFirmwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.4 | seHdpmSystemSerialNum | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.5 | seHdpmSystemSupplyType | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.6 | seHdpmSystemEnergyScale | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.8 | seHdpmSystemAmpsScale | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.9 | seHdpmSystemPowerScale | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.10 | seHdpmLoadTypeTable | 1 | 4 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.11 | seHdpmCtTypeTable | 1 | 7 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.12 | seHdpmChannelCircuitNameTable | 1 | 3 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.13 | seHdpmChannelRackNameTable | 1 | 3 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.14 | seHdpmSystemPtRatio | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.15 | seHdpmSystemImbalance_Phases | 0 | 0 | |
| 1.3.6.1.4.1.3833.1.6000.1.1.16 | seHdpmSystemZeroThreshold | 0 | 0 |