OID reference

seHdpmSystemAmpsScale

1.3.6.1.4.1.3833.1.6000.1.1.8

Description

Current scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of amps returned for circuits and channels will be in units of hunderdths of amps multiplied by this value so a value of 1000 means tens of amps.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.3833.1.6000.1.1 (seHdpmSystem)
Node code
8
Node name
seHdpmSystemAmpsScale
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.3833.1.6000.1.1.8
URN notation
urn:oid:1.3.6.1.4.1.3833.1.6000.1.1.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 3833 1 6000 1 1 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) schneiderelectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) schneiderelectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) schneiderElectric(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) transparentFactoryEthernet(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) groupeschneider(3833) schneiderEnergy(1) hdpm(6000) schneiderHDPM(1) seHdpmSystem(1) seHdpmSystemAmpsScale(8)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/3833/1/6000/1/1/8
  • /ISO/Identified-Organization/6/1/4/1/3833/1/6000/1/1/8
  • /ISO/3/6/1/4/1/3833/1/6000/1/1/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprise/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprise/schneiderelectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprises/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/enterprises/schneiderelectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/schneiderElectric/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/transparentFactoryEthernet/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/groupeschneider/schneiderEnergy/hdpm/schneiderHDPM/seHdpmSystem/seHdpmSystemAmpsScale
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1ampereHundredths
10ampereTenths
100ampere
1000ampereTens
10000ampereHundreds

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.3833.1.6000.1.1.8.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

This OID is defined in a Schneider Electric HDPM6000 MIB distributed with these firmware packages:

A definition in a firmware package does not establish that every device implements it or permits access. Other firmware versions have not been verified here.

The displayed source records contain one distinct definition. Compare its source records.

seHdpmSystemAmpsScale OBJECT-TYPE
      SYNTAX      INTEGER { ampereHundredths(1), ampereTenths(10), ampere(100), ampereTens(1000), ampereHundreds(10000) }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "Current scale factor where possible values are: 1, 10, 100, 1000, or 10000.  The
         value of amps returned for circuits and channels will be in units of hunderdths of
         amps multiplied by this value so a value of 1000 means tens of amps."
      ::= { seHdpmSystem 8 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Current scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of amps returned for circuits and channels will be in units of hunderdths of amps multiplied by this value so a value of 1000 means tens of amps.

Sources for this description

Schneider Electric HDPM6000 official MIB

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Schneider Electric HDPM6000 official MIB1 record · 2 sources

Description 1

seHdpmSystemAmpsScale · currentSchneider Electric HDPM6000 official MIB2 sources

Status in source: current.

Names: seHdpmSystemAmpsScale

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "seHdpmSystemAmpsScale",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "ampereHundredths",
    "(",
    "1",
    ")",
    ",",
    "ampereTenths",
    "(",
    "10",
    ")",
    ",",
    "ampere",
    "(",
    "100",
    ")",
    ",",
    "ampereTens",
    "(",
    "1000",
    ")",
    ",",
    "ampereHundreds",
    "(",
    "10000",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Current scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of amps returned for circuits and channels will be in units of hunderdths of amps multiplied by this value so a value of 1000 means tens of amps.\"",
    "::=",
    "{",
    "seHdpmSystem",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "ampereHundredths",
            1
          ],
          [
            "ampereTenths",
            10
          ],
          [
            "ampere",
            100
          ],
          [
            "ampereTens",
            1000
          ],
          [
            "ampereHundreds",
            10000
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Current scale factor where possible values are: 1, 10, 100, 1000, or 10000. The value of amps returned for circuits and channels will be in units of hunderdths of amps multiplied by this value so a value of 1000 means tens of amps."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.3833)

Dube Dennis

Siblings (15)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.3833.1.6000.1.1.1 seHdpmSystemChannelCount00
1.3.6.1.4.1.3833.1.6000.1.1.2 seHdpmSystemFirmwareVersion00
1.3.6.1.4.1.3833.1.6000.1.1.3 seHdpmSystemMicroFirmwareVersion00
1.3.6.1.4.1.3833.1.6000.1.1.4 seHdpmSystemSerialNum00
1.3.6.1.4.1.3833.1.6000.1.1.5 seHdpmSystemSupplyType00
1.3.6.1.4.1.3833.1.6000.1.1.6 seHdpmSystemEnergyScale00
1.3.6.1.4.1.3833.1.6000.1.1.7 seHdpmSystemVoltsScale00
1.3.6.1.4.1.3833.1.6000.1.1.9 seHdpmSystemPowerScale00
1.3.6.1.4.1.3833.1.6000.1.1.10 seHdpmLoadTypeTable14
1.3.6.1.4.1.3833.1.6000.1.1.11 seHdpmCtTypeTable17
1.3.6.1.4.1.3833.1.6000.1.1.12 seHdpmChannelCircuitNameTable13
1.3.6.1.4.1.3833.1.6000.1.1.13 seHdpmChannelRackNameTable13
1.3.6.1.4.1.3833.1.6000.1.1.14 seHdpmSystemPtRatio00
1.3.6.1.4.1.3833.1.6000.1.1.15 seHdpmSystemImbalance_Phases00
1.3.6.1.4.1.3833.1.6000.1.1.16 seHdpmSystemZeroThreshold00