Description 1
Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.38446.1.2.2.1.18
Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port.
Identification
{1 3 6 1 4 1 38446 1 2 2 1 18}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 0 | off | 1 |
| 1 | noOperation | 2 |
| 1 | on | 1 |
| 2 | reset | 2 |
| 3 | notSupported | 2 |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ENLOGIC-PDU-MIB, the row index pduUnitConfigIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.38446.1.2.2.1.18.<pduUnitConfigIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index: pduUnitConfigIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.38446.1.2.2.1.18
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
pduUnitConfigUsb OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port."
::= { pduUnitConfigEntry 18 }pduUnitConfigOutletEnergyReset OBJECT-TYPE
SYNTAX INTEGER {
noOperation (1),
reset (2),
notSupported (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this OID to reset (2) will cause the outlet energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not support this feature will respond to this OID with a
value of notSupported (3). Attempts to set this OID in these models will fail. "
::= { pduUnitConfigEntry 18 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Setting this OID to reset (2) will cause the outlet energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: pduUnitConfigUsb
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pduUnitConfigUsb",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port.\"",
"::=",
"{",
"pduUnitConfigEntry",
"18",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Setting this OID to off(0) will disable the USB port. Setting this OID to on(1) will enable the USB port."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: ENLOGIC-PDU-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Same file in Observium Community.
Status in source: current.
Names: pduUnitConfigOutletEnergyReset
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pduUnitConfigOutletEnergyReset",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"noOperation",
"(",
"1",
")",
",",
"reset",
"(",
"2",
")",
",",
"notSupported",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Setting this OID to reset (2) will cause the outlet energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. \"",
"::=",
"{",
"pduUnitConfigEntry",
"18",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"noOperation",
1
],
[
"reset",
2
],
[
"notSupported",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Setting this OID to reset (2) will cause the outlet energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: ENLOGIC-PDU2-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.38446.1.2.2.1.1 | pduUnitConfigIndex | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.2 | pduUnitConfigName | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.3 | pduUnitConfigLocation | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.4 | pduUnitConfigDisplayOrientation | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.5 | pduUnitConfigColdstartDelay, pduUnitConfigOledDisplayControl | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.6 | pduUnitConfigGlobalOutletStateOnStartup, pduUnitConfigColdstartDelay | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.7 | pduUnitConfigLowerCriticalThreshold, pduUnitConfigGlobalOutletStateOnStartup | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.8 | pduUnitConfigLowerWarningThreshold, pduUnitConfigLowerCriticalThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.9 | pduUnitConfigUpperCriticalThreshold, pduUnitConfigLowerWarningThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.10 | pduUnitConfigUpperWarningThreshold, pduUnitConfigUpperCriticalThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.11 | pduUnitConfigAlarmResetThreshold, pduUnitConfigUpperWarningThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.12 | pduUnitConfigAlarmStateChangeDelay, pduUnitConfigAlarmResetThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.13 | pduUnitConfigEnabledThresholds, pduUnitConfigAlarmStateChangeDelay | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.14 | pduUnitConfigPeakPowerReset, pduUnitConfigEnabledThresholds | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.15 | pduUnitConfigEnergyReset, pduUnitConfigPeakPowerReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.16 | pduUnitConfigOutletPeakPowerReset, pduUnitConfigEnergyReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.17 | pduUnitConfigOutletEnergyReset, pduUnitConfigOutletPeakPowerReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.19 | pduUnitConfigSsh, pduUnitConfigUsb | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.20 | pduUnitConfigResetNetworkManagementCard, pduUnitConfigSsh | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.21 | pduUnitConfigDaisyChainState, pduUnitConfigResetNetworkManagementCard | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.22 | pduUnitConfigDaisyChainState | 0 | 0 |