Description 1
User-defined lower critical unit active power alarm threshold measured in Watts
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.38446.1.2.2.1.7
User-defined lower critical unit active power alarm threshold measured in Watts
Identification
{1 3 6 1 4 1 38446 1 2 2 1 7}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 0 | off | 2 |
| 1 | on | 2 |
| 2 | lastKnownState | 2 |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ENLOGIC-PDU-MIB, the row index pduUnitConfigIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.38446.1.2.2.1.7.<pduUnitConfigIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index: pduUnitConfigIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.38446.1.2.2.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
pduUnitConfigLowerCriticalThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User-defined lower critical unit active power alarm threshold measured in Watts"
::= { pduUnitConfigEntry 7 }pduUnitConfigGlobalOutletStateOnStartup OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1),
lastKnownState (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The outlet state on device startup; applies to all outlets
unless overridden at the outlet level"
::= { pduUnitConfigEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
User-defined lower critical unit active power alarm threshold measured in Watts
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
The outlet state on device startup; applies to all outlets unless overridden at the outlet level
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: pduUnitConfigLowerCriticalThreshold
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pduUnitConfigLowerCriticalThreshold",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"User-defined lower critical unit active power alarm threshold measured in Watts\"",
"::=",
"{",
"pduUnitConfigEntry",
"7",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"User-defined lower critical unit active power alarm threshold measured in Watts"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: ENLOGIC-PDU-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Related source files and packages:
Same file in Observium Community.
Status in source: current.
Names: pduUnitConfigGlobalOutletStateOnStartup
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pduUnitConfigGlobalOutletStateOnStartup",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on",
"(",
"1",
")",
",",
"lastKnownState",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The outlet state on device startup; applies to all outlets unless overridden at the outlet level\"",
"::=",
"{",
"pduUnitConfigEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on",
1
],
[
"lastKnownState",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The outlet state on device startup; applies to all outlets unless overridden at the outlet level"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: ENLOGIC-PDU2-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.38446.1.2.2.1.1 | pduUnitConfigIndex | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.2 | pduUnitConfigName | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.3 | pduUnitConfigLocation | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.4 | pduUnitConfigDisplayOrientation | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.5 | pduUnitConfigColdstartDelay, pduUnitConfigOledDisplayControl | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.6 | pduUnitConfigGlobalOutletStateOnStartup, pduUnitConfigColdstartDelay | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.8 | pduUnitConfigLowerWarningThreshold, pduUnitConfigLowerCriticalThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.9 | pduUnitConfigUpperCriticalThreshold, pduUnitConfigLowerWarningThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.10 | pduUnitConfigUpperWarningThreshold, pduUnitConfigUpperCriticalThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.11 | pduUnitConfigAlarmResetThreshold, pduUnitConfigUpperWarningThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.12 | pduUnitConfigAlarmStateChangeDelay, pduUnitConfigAlarmResetThreshold | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.13 | pduUnitConfigEnabledThresholds, pduUnitConfigAlarmStateChangeDelay | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.14 | pduUnitConfigPeakPowerReset, pduUnitConfigEnabledThresholds | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.15 | pduUnitConfigEnergyReset, pduUnitConfigPeakPowerReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.16 | pduUnitConfigOutletPeakPowerReset, pduUnitConfigEnergyReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.17 | pduUnitConfigOutletEnergyReset, pduUnitConfigOutletPeakPowerReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.18 | pduUnitConfigUsb, pduUnitConfigOutletEnergyReset | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.19 | pduUnitConfigSsh, pduUnitConfigUsb | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.20 | pduUnitConfigResetNetworkManagementCard, pduUnitConfigSsh | 0 | 0 | |
| 1.3.6.1.4.1.38446.1.2.2.1.21 | pduUnitConfigDaisyChainState, pduUnitConfigResetNetworkManagementCard | 0 | 0 | |