Specifies the estimated percent of flash memory currently in
use. The percentage is based on the portion of flash that is
designated for use by the user's database. The value is updated
on device startup, after a database archive, sync or download
from the SCT (offline mode); and by manual command (Update
Flash Usage). A value greater than 100% can affect system
reliability now or in future software releases. There are no
restrictions in place to prohibit use of flash over 100%.
Parsed from file msea.mib.txt
Company: johnsoncontrols
Module: MSEA-MIB
flashUsage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the estimated percent of flash memory currently in use. The percentage is based on the portion of flash that is designated for use by the user's database. The value is updated on device startup, after a database archive, sync or download from the SCT (offline mode); and by manual command (Update Flash Usage). A value greater than 100% can affect system reliability now or in future software releases. There are no restrictions in place to prohibit use of flash over 100%." ::= { mseaDiagnostics 2584 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4399.2.1.1.1.1.3.647 | batteryCondition | 0 | 0 | Specifies the current battery condition. It is updated every 60 seconds. |
1.3.6.1.4.1.4399.2.1.1.1.1.3.650 | covReceivesPerMinute | 0 | 0 | Specifies the number of COV messages the NAE receives from other supervisory devices or field controllers per minute. This attrib… |
1.3.6.1.4.1.4399.2.1.1.1.1.3.651 | covTransmitsPerMinute | 0 | 0 | Specifies the number of COV messages the NAE sends to other supervisory devices per minute. This attribute updates every minute. … |
1.3.6.1.4.1.4399.2.1.1.1.1.3.844 | objectCount | 0 | 0 | Indicates the number (count) of all the object instances within the device. Objects of all classes are included. |
1.3.6.1.4.1.4399.2.1.1.1.1.3.2395 | estimatedFlashAvailable | 0 | 0 | Specifies the estimated flash memory available within the device for use by the user's database and applications. This value can … |
1.3.6.1.4.1.4399.2.1.1.1.1.3.2579 | cpuTemperature | 0 | 0 | Specifies the current CPU (Central Processing Unit) temperature in degrees Celsius for an NAE45-0/NAE55/NIE55. It is updated ever… |
1.3.6.1.4.1.4399.2.1.1.1.1.3.2580 | boardTemperature | 0 | 0 | Specifies the current Printed Wiring Board (PWB) temperature in degrees Celsius. It is updated every 60 seconds. It is obtained f… |
1.3.6.1.4.1.4399.2.1.1.1.1.3.2581 | memoryUsage | 0 | 0 | Specifies the percent of system RAM that is currently in use. |
1.3.6.1.4.1.4399.2.1.1.1.1.3.2582 | objectMemoryUsage | 0 | 0 | Specifies the percent of the object database that is currently in use. Each object created consumes memory within the object data… |
1.3.6.1.4.1.4399.2.1.1.1.1.3.2583 | cpuUsage | 0 | 0 | Specifies a running average of CPU utilization over the last 50 minutes. The value is updated every 30 seconds. The running avera… |
1.3.6.1.4.1.4399.2.1.1.1.1.3.32565 | pagerDialStatus | 0 | 0 | Specifies the current status of the pager dial-up connection |