This object identifies the three possible states which data bypass
can be in. '1' means frame relay data bypass is off.
'2' means frame relay data bypass is on.
'3' means frame relay data bypass is on and was set on
automatically because there was no DCD and no RTS.
State '1' can only be set if state is '2'.
State '2' can only be set if state is '1'.
State '3' cannot be set manually.
Parsed from file TelenaLPLMseries.mib.txt
Company: None
Module: LINK_PROBE-MIB
This object identifies the three possible states which data bypass
can be in. '1' means frame relay data bypass is off.
'2' means frame relay data bypass is on.
'3' means frame relay data bypass is on and was set on
automatically because there was no DCD and no RTS.
State '1' can only be set if state is '2'.
State '2' can only be set if state is '1'.
State '3' cannot be set manually.
Parsed from file LINK-PROBE-MIB.mib
Module: LINK-PROBE-MIB
Vendor: NetQuest Corp.
Module: LINK_PROBE-MIB
[Automatically extracted from oidview.com]
bypassStatus OBJECT-TYPE SYNTAX INTEGER { bypass_off(1), bypass_on(2), bypass_auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION " This object identifies the three possible states which data bypass can be in. '1' means frame relay data bypass is off. '2' means frame relay data bypass is on. '3' means frame relay data bypass is on and was set on automatically because there was no DCD and no RTS. State '1' can only be set if state is '2'. State '2' can only be set if state is '1'. State '3' cannot be set manually." ::={ pro_fun_config 12 }
bypassStatus OBJECT-TYPE SYNTAX INTEGER { bypass-off(1), bypass-on(2), bypass-auto(3) } ACCESS read-write STATUS mandatory DESCRIPTION " This object identifies the three possible states which data bypass can be in. '1' means frame relay data bypass is off. '2' means frame relay data bypass is on. '3' means frame relay data bypass is on and was set on automatically because there was no DCD and no RTS. State '1' can only be set if state is '2'. State '2' can only be set if state is '1'. State '3' cannot be set manually." ::={ pro-fun-config 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.568.8.1.3.12.0 | bypassStatus | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.568.8.1.3.1 | softwareVersion | 1 | 1 | This object displays the software version we are currently running, so according to the version number, the user can determine wh… |
1.3.6.1.4.1.568.8.1.3.2 | probe_Mode, probe-Mode | 1 | 1 | Probe mode defines whether the link probe is generator, responder, both or disabled. |
1.3.6.1.4.1.568.8.1.3.3 | poll_Period, poll-Period | 1 | 1 | poll period defines the frequency of sending the polling frame by the link probe. The value is between 1 to 60 sec. The poll per… |
1.3.6.1.4.1.568.8.1.3.4 | sys_current_time, sys-current-time | 1 | 1 | sys_current_time displays the system current time with 4 digits year, 2 digits month, 2 digits date and hours, minutes and second… |
1.3.6.1.4.1.568.8.1.3.5 | current_intv_start_time, current-intv-start-time | 1 | 1 | current_intv_start_time displays the current interval starting time with 4 digits year, 2 digits month, 2 digits date and hours, … |
1.3.6.1.4.1.568.8.1.3.6 | pvc_Count, pvc-Count | 1 | 1 | PVC count defines the total number of PVCs which are to be probed. The value is between 1 to 20. |
1.3.6.1.4.1.568.8.1.3.7 | probeTokenSize | 1 | 1 | This object defines the probe token size. |
1.3.6.1.4.1.568.8.1.3.8 | pvc_add, pvc-add | 1 | 1 | This object allows the user to add a PVC to the existing PVC table, the added PVC must not exist before it is added. |
1.3.6.1.4.1.568.8.1.3.9 | pvc_delete, pvc-delete | 1 | 1 | This object allows the user to delete a PVC from the existing PVC table, the deleted PVC must exist before it was deleted. |
1.3.6.1.4.1.568.8.1.3.10 | pvc_Table, pvc-Table | 1 | 4 | PVC table, which lists PVCs that currently are probed. |
1.3.6.1.4.1.568.8.1.3.11 | alternateVersion | 1 | 1 | This object displays the software version we are not currently running, so according to the version number, the user can determin… |