This object allows the user to delete a PVC from the existing PVC
table, the deleted PVC must exist before it was deleted.
Parsed from file TelenaLPLMseries.mib.txt
Company: None
Module: LINK_PROBE-MIB
This object allows the user to delete a PVC from the existing PVC
table, the deleted PVC must exist before it was deleted.
Parsed from file LINK-PROBE-MIB.mib
Module: LINK-PROBE-MIB
Vendor: NetQuest Corp.
Module: LINK_PROBE-MIB
[Automatically extracted from oidview.com]
pvc_delete OBJECT-TYPE SYNTAX INTEGER ( 16..991 ) ACCESS write-only STATUS mandatory DESCRIPTION " This object allows the user to delete a PVC from the existing PVC table, the deleted PVC must exist before it was deleted." ::={ pro_fun_config 9 }
pvc-delete OBJECT-TYPE SYNTAX INTEGER ( 16..991 ) ACCESS write-only STATUS mandatory DESCRIPTION " This object allows the user to delete a PVC from the existing PVC table, the deleted PVC must exist before it was deleted." ::={ pro-fun-config 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.568.8.1.3.9.0 | 0 | 0 | 0 | pvc_delete |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.568.8.1.3.1 | softwareVersion | 1 | 1 | This object displays the software version we are currently running, so according to the version number, the user can determine wh… |
1.3.6.1.4.1.568.8.1.3.2 | probe_Mode, probe-Mode | 1 | 1 | Probe mode defines whether the link probe is generator, responder, both or disabled. |
1.3.6.1.4.1.568.8.1.3.3 | poll_Period, poll-Period | 1 | 1 | poll period defines the frequency of sending the polling frame by the link probe. The value is between 1 to 60 sec. The poll per… |
1.3.6.1.4.1.568.8.1.3.4 | sys_current_time, sys-current-time | 1 | 1 | sys_current_time displays the system current time with 4 digits year, 2 digits month, 2 digits date and hours, minutes and second… |
1.3.6.1.4.1.568.8.1.3.5 | current_intv_start_time, current-intv-start-time | 1 | 1 | current_intv_start_time displays the current interval starting time with 4 digits year, 2 digits month, 2 digits date and hours, … |
1.3.6.1.4.1.568.8.1.3.6 | pvc_Count, pvc-Count | 1 | 1 | PVC count defines the total number of PVCs which are to be probed. The value is between 1 to 20. |
1.3.6.1.4.1.568.8.1.3.7 | probeTokenSize | 1 | 1 | This object defines the probe token size. |
1.3.6.1.4.1.568.8.1.3.8 | pvc_add, pvc-add | 1 | 1 | This object allows the user to add a PVC to the existing PVC table, the added PVC must not exist before it is added. |
1.3.6.1.4.1.568.8.1.3.10 | pvc_Table, pvc-Table | 1 | 4 | PVC table, which lists PVCs that currently are probed. |
1.3.6.1.4.1.568.8.1.3.11 | alternateVersion | 1 | 1 | This object displays the software version we are not currently running, so according to the version number, the user can determin… |
1.3.6.1.4.1.568.8.1.3.12 | bypassStatus | 1 | 1 | This object identifies the three possible states which data bypass can be in. '1' means frame relay data bypass is off. '2' means… |