Status in source: current.
Names: mesErpHoldOffTime
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mesErpHoldOffTime",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"10000",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"A hold-off timer coordinates timing of protection switches between multiple layers. The timer gives another protection layer the possibility to solve the issue before performing the protection switch. When a signal fail event occurs, this event is not reported until the hold-off timer has elapsed. The hold-off time is defined in steps of 100 milliseconds. Note! A non-zero hold-off time will impact the protection switch time performance. \"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"mesErpEntry",
"12",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
10000
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A hold-off timer coordinates timing of protection switches between multiple layers. The timer gives another protection layer the possibility to solve the issue before performing the protection switch. When a signal fail event occurs, this event is not reported until the hold-off timer has elapsed. The hold-off time is defined in steps of 100 milliseconds. Note! A non-zero hold-off time will impact the protection switch time performance."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}