Defines whether OAM signal failure detection is enabled on the left ERP port.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.8708.2.32.2.26.1.1.14
Defines whether OAM signal failure detection is enabled on the left ERP port.
Identification
{1 3 6 1 4 1 8708 2 32 2 26 1 1 14}
| Value | Name |
|---|---|
| 1 | disabled |
| 2 | enabled |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: mesErpIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.8708.2.32.2.26.1.1.14
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
mesErpOamDetectionLeft OBJECT-TYPE
SYNTAX INTEGER {
disabled (1),
enabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether OAM signal failure detection is
enabled on the left ERP port.
"
DEFVAL { disabled }
::= { mesErpEntry 14 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Defines whether OAM signal failure detection is enabled on the left ERP port.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: mesErpOamDetectionLeft
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mesErpOamDetectionLeft",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"disabled",
"(",
"1",
")",
",",
"enabled",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Defines whether OAM signal failure detection is enabled on the left ERP port. \"",
"DEFVAL",
"{",
"disabled",
"}",
"::=",
"{",
"mesErpEntry",
"14",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"disabled",
1
],
[
"enabled",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Defines whether OAM signal failure detection is enabled on the left ERP port."
],
null,
null,
null,
[
"DEFVAL",
"disabled"
]
]
}Vendor MIB copy from the Observium Community archive.
Module: LUM-MES-MIB
See published definition above
{'LUM-TC': ['MgmtNameString', 'SubrackNumber', 'SlotNumber', 'PortNumber', 'BoardOrInterfaceOperStatus', 'BoardOrInterfaceAdminStatus', 'ObjectProperty', 'CommandString', 'FaultStatus', 'ServiceIdWithNotUsed'], 'LUM-REG': ['lumModules', 'lumMesMIB'], 'SNMPv2-TC': ['DisplayString', 'DateAndTime', 'RowStatus', 'MacAddress', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'IpAddress', 'Counter64'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE']}Related source files and packages:
Registration