OID reference

alarmC4Hours

1.3.6.1.4.1.9839.2.1.1.56

Description

ServiceAlarm: Compressor 4 hour counter threshold

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.1 (digitalObjects)
Node code
56
Node names
  • alarmC4Hours
  • enable-pressure-recovery
  • seetag-cust-alm1
  • range-t-ac
  • all_sonda_def
  • a1_ea
  • mal_broke_pr3
  • rotaz_compr_r5
  • inverter_steps
  • off_ventp_defr
  • mal_fan2
  • si_sond_acqua
  • a2_ed
  • mall_term_klix4
  • set_2_param_p6
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.1.56
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.1.56
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 1 56}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) alarmC4Hours(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) enable-pressure-recovery(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) seetag-cust-alm1(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) range-t-ac(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) alarmC4Hours(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) enable-pressure-recovery(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) seetag-cust-alm1(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) range-t-ac(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) digitalObjects(1) alarmC4Hours(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) digitalObjects(1) enable-pressure-recovery(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) digitalObjects(1) seetag-cust-alm1(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) digitalObjects(1) range-t-ac(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) digitalObjects(1) alarmC4Hours(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) digitalObjects(1) enable-pressure-recovery(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) digitalObjects(1) seetag-cust-alm1(56)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) digitalObjects(1) range-t-ac(56)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/1/56
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/1/56
  • /ISO/3/6/1/4/1/9839/2/1/1/56
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/alarmC4Hours
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/enable-pressure-recovery
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/seetag-cust-alm1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/range-t-ac
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/all_sonda_def
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/a1_ea
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/mal_broke_pr3
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/rotaz_compr_r5
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/inverter_steps
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/off_ventp_defr
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/mal_fan2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/si_sond_acqua
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/a2_ed
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/mall_term_klix4
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/set_2_param_p6
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/digitalObjects/alarmC4Hours
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, flag
Maximum access defined by MIB
read-only, read-write
Status in MIB
current
Default value
0, 3, 1

Definitions may combine these properties differently.

Compare 7 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–1

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
3
Allowed ranges
0–1

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
flag
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
0–1

Variant 7 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
0–1

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.1.56.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 15 distinct definitions; some records may not include a definition.

Show 15 published definitions

seetag-cust-alm1 · current

seetag-cust-alm1 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Local alarm #1: See tag inside door =Optional alarm. External alarm input required"
                    DEFVAL { 0 }
                    ::= { digitalObjects 56 }

alarmC4Hours · current

alarmC4Hours OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "ServiceAlarm: Compressor 4 hour counter threshold"
                    ::= { digitalObjects 56 }

mal_fan2 · current

mal_fan2 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Fan 2 thermal overload alarm"
                    ::= { digitalObjects 56 }

range-t-ac · current

range-t-ac OBJECT-TYPE
                    SYNTAX Integer32
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Hot water temp. Sensor Fitted"
                    ::= { digitalObjects 56 }

mal_broke_pr3 · current

mal_broke_pr3 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe 3 is not connected and does not operate"
                    ::= { digitalObjects 56 }

rotaz_compr_r5 · current

rotaz_compr_r5 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Compressor rotation"
                    DEFVAL { 3 }
                    ::= { digitalObjects 56 }

set_2_param_p6 · current

set_2_param_p6 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "flag"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "2nd set of param."
                    DEFVAL { 0 }
                    ::= { digitalObjects 56 }

inverter_steps · current

inverter_steps OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Select operation, inverter or stepped"
                    ::= { digitalObjects 56 }

si_sond_acqua · current

si_sond_acqua OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Outlet water probe enabling"
                    ::= { digitalObjects 56 }

off_ventp_defr · current

off_ventp_defr OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Enabling of main fan OFF during defrost"
                    DEFVAL { 1 }
                    ::= { digitalObjects 56 }

enable-pressure-recovery · current

enable-pressure-recovery OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Enable pressure recovery"
                    ::= { digitalObjects 56 }

a1_ea · current

a1_ea OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "E2P/clock alarm"
                    ::= { digitalObjects 56 }

a2_ed · current

a2_ed OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Defrost ended by time-out"
                    ::= { digitalObjects 56 }

mall_term_klix4 · current

mall_term_klix4 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Thermal overload alarm compressor 4"
                    ::= { digitalObjects 56 }

all_sonda_def · current

all_sonda_def OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Defrost probe alarm (S2)"
                    DEFVAL { 0 }
                    ::= { digitalObjects 56 }

Meaning

Descriptions

15 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

ServiceAlarm: Compressor 4 hour counter threshold
Original text from OID Repository
alarmC4Hours OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ServiceAlarm: Compressor 4 hour counter threshold"
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Local alarm #1: See tag inside door =Optional alarm. External alarm input required

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Fan 2 thermal overload alarm

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Hot water temp. Sensor Fitted

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Probe 3 is not connected and does not operate

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

Compressor rotation

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 7

2nd set of param.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 8

Select operation, inverter or stepped

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 9

Outlet water probe enabling

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 10

Enabling of main fan OFF during defrost

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 11

Enable pressure recovery

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 12

E2P/clock alarm

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 13

Defrost ended by time-out

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 14

Thermal overload alarm compressor 4

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 15

Defrost probe alarm (S2)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

15 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 2

seetag-cust-alm1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: seetag-cust-alm1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "seetag-cust-alm1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Local alarm #1: See tag inside door =Optional alarm. External alarm input required\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Local alarm #1: See tag inside door =Optional alarm. External alarm input required"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

alarmC4Hours · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: alarmC4Hours

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "alarmC4Hours",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"ServiceAlarm: Compressor 4 hour counter threshold\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "ServiceAlarm: Compressor 4 hour counter threshold"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

mal_fan2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: mal_fan2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "mal_fan2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Fan 2 thermal overload alarm\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Fan 2 thermal overload alarm"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

range-t-ac · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: range-t-ac

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "range-t-ac",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hot water temp. Sensor Fitted\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hot water temp. Sensor Fitted"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

mal_broke_pr3 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: mal_broke_pr3

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "mal_broke_pr3",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe 3 is not connected and does not operate\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe 3 is not connected and does not operate"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

rotaz_compr_r5 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rotaz_compr_r5

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rotaz_compr_r5",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Compressor rotation\"",
    "DEFVAL",
    "{",
    "3",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Compressor rotation"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      3
    ]
  ]
}
Records for description 7Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 7

set_2_param_p6 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: set_2_param_p6

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "set_2_param_p6",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "22666c616722"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"2nd set of param.\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "flag"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "2nd set of param."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 8Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 8

inverter_steps · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: inverter_steps

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "inverter_steps",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Select operation, inverter or stepped\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Select operation, inverter or stepped"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 9Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 9

si_sond_acqua · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: si_sond_acqua

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "si_sond_acqua",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Outlet water probe enabling\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Outlet water probe enabling"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 10Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 10

off_ventp_defr · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: off_ventp_defr

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "off_ventp_defr",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Enabling of main fan OFF during defrost\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Enabling of main fan OFF during defrost"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}
Records for description 11Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 11

enable-pressure-recovery · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: enable-pressure-recovery

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "enable-pressure-recovery",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Enable pressure recovery\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Enable pressure recovery"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 12Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 12

a1_ea · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: a1_ea

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "a1_ea",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"E2P/clock alarm\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "E2P/clock alarm"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 13Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 13

a2_ed · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: a2_ed

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "a2_ed",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Defrost ended by time-out\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Defrost ended by time-out"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 14Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 14

mall_term_klix4 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: mall_term_klix4

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "mall_term_klix4",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Thermal overload alarm compressor 4\"",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Thermal overload alarm compressor 4"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 15Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 15

all_sonda_def · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: all_sonda_def

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "all_sonda_def",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Defrost probe alarm (S2)\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "56",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Defrost probe alarm (S2)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (185)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.1.51 alarmRHS, manual-reset-static-press-Alarm, glb-al, glb_al, all_ext_del, a1_e1, mal_maint_dev10, sel_rele_all_hf, cooling_heating, en_stampante, mal_oil_level, s_epromnook, a1_id, din107, def_ext_da00 Alarm: Room Humidity Sensor Failed/Disconnected
1.3.6.1.4.1.9839.2.1.1.52 alarmCWOTS, enable-static-press-Warning, lead-comp, or-al-2lev, all_ext_ist, a1_e2, mal_maint_dev11, en_freecool, mal_low_pres, buzz_output, a2_hi, din108, anti_def_db00 Alarm: Chilled Water Outlet T. Sensor Failed/Disconnected
1.3.6.1.4.1.9839.2.1.1.53 alarmC1Hours, manual-reset-static-press-Warning, wtrvlv-dir, range-t-ext, all_ha, a1_e3, mal_m_invdev1, cond_config, en_freeheat, mal_hp_transd, pro_pi, rele1_output, a2_lo, mall_term_klix1, end_def_de00 ServiceAlarm: Compressor 1 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.54 alarmC2Hours, enable-diff-press-Alarm, ups-on-alm, range-t-circ, all_hf, a1_ia, mal_broke_pr1, mal_serious, a2_ha, mall_term_klix2, sup_probe_a600 ServiceAlarm: Compressor 2 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.55 alarmC3Hours, manual-reset-diff-press-Alarm, pwrup-alm, range-t-man, all_sonda_amb, a1_da, mal_broke_pr2, ab_estate_inv_h6, en_compensazio, mal_fan1, si_sond_umid, a2_hf, mall_term_klix3, reset_alarm_p500 ServiceAlarm: Compressor 3 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.57 alarmFilterHours, enable-Flow-Rate-Alarm, seetag-cust-alm2, umid-al, all_sonda_prod, a1_re, mal_pres_hpres, inverter, en_sbrin_cont, mal_pump_evap, si_sond_aria, mall_term_klix5, low_press_alarm_p700 ServiceAlarm: Air Filter hour counter threshold
1.3.6.1.4.1.9839.2.1.1.58 alarmHeat1Hours, manual-reset-Flow-Rate-Alarm, seetag-cust-alm3, range-u-amb, all_sonda_reg, a1_id, mal_pres_lpres, fc_valve_type, autostart, mal_master_offl, si_sond_acquain, mall_term_klix600 ServiceAlarm: Heater 1 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.59 alarmHeat2Hours, enable-Flow-Rate-recovery, seetag-cust-alm4, all_tem_min_s1, a2_hi, mal_block_dev1, not_fc_vlv_type, en_remoto, mal_unit2_offl, si_sond_ariain, mall_pres_h100 ServiceAlarm: Heater 1 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.60 alarmHumHours, enable-pCOWeb, shortcycle-alm-en, k-syson, mal_block_dev2, unloads_logic, mal_unit3_offl, bin_sta, mall_pres_h2, def_cmd00 ServiceAlarm: Humidifier hour counter threshold
1.3.6.1.4.1.9839.2.1.1.61 alarmUnitHours, fc-single-chiller, superv-off, xs-res-al, a2_ha, mal_block_dev3, valve4way_logic, mal_unit4_offl, si_rampap, mall_pres_h300 ServiceAlarm: Unit hour counter threshold
1.3.6.1.4.1.9839.2.1.1.62 alarmDI2, BMS-heartbeat, a2_hf, mal_block_dev4, mal_b1, es, mall_pres_h400 Alarm by Digital Input 2
1.3.6.1.4.1.9839.2.1.1.63 alarmDI4, sleep-mode, mal_block_dev5, mal_b2, si_comp_es, mall_pres_h500 Alarm by Digital Input 4
1.3.6.1.4.1.9839.2.1.1.64 alarmDI6, test-sm, a4_hc, mal_block_dev6, abil_rotaz, mal_b3, si_rampan, mall_pres_h600 Alarm by Digital Input 6
1.3.6.1.4.1.9839.2.1.1.65 alarmHum, ab-mediath, a4_pd, mal_block_dev7, sys_on, mal_b4, si_parz, mall_dif_olio100 Humidifier General Alarm
1.3.6.1.4.1.9839.2.1.1.66 alarmGeneral, ustdby1-2, a4_bp, mal_block_dev8, mal_b5, si_rot2, mall_dif_olio200 General Alarm
1.3.6.1.4.1.9839.2.1.1.67 alarm2ndLevel, emerg, mal_block_dev9, mal_b6, si_comp1_deu, mall_dif_olio300 Standby Unit Switchover Alarm
1.3.6.1.4.1.9839.2.1.1.68 alarmA, mal_block_dev10, mal_b7, si_comp2_deu, mall_dif_olio400 Type A Alarm
1.3.6.1.4.1.9839.2.1.1.69 alarmB, mal_block_dev11, mal_b8, mall_dif_olio500 Type B Alarm
1.3.6.1.4.1.9839.2.1.1.70 alarmC, mal_high1, glb_al, mal_pump_cond_h, mall_dif_olio600 Type C Alarm
1.3.6.1.4.1.9839.2.1.1.71 selDXCW, digital_out_2, mal_low1, man_freeze, mal_comp_hour, si_fasce, mall_ore_comp100 DX/CW Switch on TC Units
1.3.6.1.4.1.9839.2.1.1.72 selSW, mal_high2, mal_ov1, mal_pump_cond, mall_ore_comp200 Summer/Winter Switchover
1.3.6.1.4.1.9839.2.1.1.73 digital_out_4, mal_low2, mal_ov2, mal_clock32, syson, mall_ore_comp300
1.3.6.1.4.1.9839.2.1.1.74 mal_n_devices, mal_ov3, syson1, mal_phase, si_rampap3v, mall_ore_comp400
1.3.6.1.4.1.9839.2.1.1.75 systemOnOff, al-idrofrigo-pump-c-1, digital_out_6, mepromnook, mal_ov4, en_binati, mal_ld_transd, si_rampan3v, mall_ore_comp500 System On-Off
1.3.6.1.4.1.9839.2.1.1.76 resetAlarm, al-idrofrigo-pump-c-2, digital_out_7, mal_clock, mal_cflow, en_sond_text, mal_voltage, manuale, mall_ore_comp600 Alarm Reset
1.3.6.1.4.1.9839.2.1.1.77 resetHrsFilt, digital_out_8, syson, mal_eflow, en_sond_uext, mal_current, start_off, mall_term_vent100 Filter Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.78 resetHrC1, digital_out_9, mal_hp1, en_sond_def1, mal_pump_ev_h, mall_term_vent200 Compressor 1 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.79 resetHrC2, mal_hp2, en_sond_def2, mall_term_vent300 Compressor 2 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.80 resetHrC3, al-idrofrigo-fl-C, mal_od1, mal_disch_temp, alarm_e06, mall_term_vent400 Compressor 3 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.81 resetHrC4, mal_od2, mal_diff_pres, alarm_e08, mal_liquid_level00 Compressor 4 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.82 resetStC1, mal_lp1, mal_alco1_67_r, alarm_e09, mall_pres_lpres00 Compressor 1 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.83 resetStC2, mal_lp2, mal_alco1_68_r, alarm_e10, mall_pres_hpres00 Compressor 2 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.84 resetStC3, mal_hpt1, mal_alco1_69_r, alarm_e11, mal_low200 Compressor 3 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.85 resetStC4, mal_hpt2, mal_alco1_70_r, alarm_e12, mall_alta_mand00 Compressor 4 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.86 resetHrH1, mal_serious, tipo_cont, mal_alco1_71_r, mal_low_press00 Heater 1 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.87 resetHrH2, mal_f1_overload, mal_alco1_72_r, mal_high_press00 Heater 2 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.88 resetStH1, sl_alm_1, mal_f2_overload, mal_alco1_73_r, mal_n_input00 Heater 1 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.89 resetStH2, mal_f3_overload, mal_alco1_74_r, mal_n_devices00 Heater 2 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.90 resetHrHU, mal_fan, mal_alco1_75_r, mall_ora00 Humidifier Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.91 resetStHU, mal_cpump, mal_alco1_760_r, mal_broke_pr100 Humidifier Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.92 resetHrACU, mal_pump, mal_alco1_97_r, mal_broke_pr200 Unit Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.93 mal_unit1_offl, glb_al00
1.3.6.1.4.1.9839.2.1.1.94 mal_unit2_offl00
1.3.6.1.4.1.9839.2.1.1.95 sleepmode, sv_mst_defrost_end, mal_unit3_offl00 Setback Mode (Sleep Mode)
1.3.6.1.4.1.9839.2.1.1.96 smtest, sv_mst_defrost_start, mal_unit4_offl00 Sleep Mode Test
1.3.6.1.4.1.9839.2.1.1.97 enablemeanT, sw_door_brk, mal_b100 Local/Mean Usage of Values
1.3.6.1.4.1.9839.2.1.1.98 mal_b200
1.3.6.1.4.1.9839.2.1.1.99 mal_b300
1.3.6.1.4.1.9839.2.1.1.100 c11-on, mal_b400
1.3.6.1.4.1.9839.2.1.1.101 c12-on, mal_b5, syson00