Reference record for OID 1.3.6.1.2.1.10.44.1.3.1.10



parent
1.3.6.1.2.1.10.44.1.3.1 (frPVCEndptEntry)
node code
10
node name
frPVCEndptConnectIdentifier
dot oid
1.3.6.1.2.1.10.44.1.3.1.10
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptConnectIdentifier(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptConnectIdentifier(10)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptConnectIdentifier(10)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptConnectIdentifier(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptConnectIdentifier(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptConnectIdentifier(10)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptConnectIdentifier
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptConnectIdentifier
  • /iso/org/dod/internet/mgmt/mib-2/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptConnectIdentifier
  • /iso/org/dod/internet/mgmt/mib/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptConnectIdentifier
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptConnectIdentifier
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptConnectIdentifier
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/44/1/3/1/10

    Description by oid_info

    frPVCEndptConnectIdentifier OBJECT-TYPE SYNTAX Integer32 (0..2147483647)
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "This object is used to associate PVC end-points
    as being part of one PVC segment connection. This
    value of this object is equal to the value of
    frPVCConnectIndex, which is used as one of the
    indices into the frPVCConnectTable.
    A connection that has been cross-connected via the
    FR/ATM PVC Service IWF cross-connect table will
    return the value zero when this object is read. In
    case of these interworked connections, the
    frPVCEndptAtmIwfConnIndex object must be accessed
    to select the entry in the FR/ATM PVC Service IWF
    cross-connect table.
    The value of this object is provided by the agent,
    after the associated entries in the
    frPVCConnectTable or frAtmIwfConnectionTable have
    been created."

    View at oid-info.com

    Description by mibdepot

    This object is used to associate PVC end-points
    as being part of one PVC segment connection. This
    value of this object is equal to the value of


    frPVCConnectIndex, which is used as one of the
    indices into the frPVCConnectTable. The value of
    this object is provided by the agent, after the
    associated entries in the frPVCConnectTable have
    been created.

    Parsed from file rfc1604.mib.txt
    Company: None
    Module: FRNETSERV-MIB

    Description by circitor

    This object is used to associate PVC end-points
    as being part of one PVC segment connection. This
    value of this object is equal to the value of
    frPVCConnectIndex, which is used as one of the
    indices into the frPVCConnectTable.

    A connection that has been cross-connected via the
    FR/ATM PVC Service IWF cross-connect table will
    return the value zero when this object is read. In
    case of these interworked connections, the
    frPVCEndptAtmIwfConnIndex object must be accessed

    to select the entry in the FR/ATM PVC Service IWF
    cross-connect table.

    The value of this object is provided by the agent,
    after the associated entries in the
    frPVCConnectTable or frAtmIwfConnectionTable have
    been created.

    Parsed from file FRNETSERV-MIB.mib
    Module: FRNETSERV-MIB

    Information by oid_info

    Automatically extracted from RFC2954

    Information by mibdepot

    frPVCEndptConnectIdentifier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to associate PVC end-points as being part of one PVC segment connection. This value of this object is equal to the value of frPVCConnectIndex, which is used as one of the indices into the frPVCConnectTable. The value of this object is provided by the agent, after the associated entries in the frPVCConnectTable have been created." ::= { frPVCEndptEntry 10 }

    Information by circitor

    frPVCEndptConnectIdentifier OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to associate PVC end-points as being part of one PVC segment connection. This value of this object is equal to the value of frPVCConnectIndex, which is used as one of the indices into the frPVCConnectTable. A connection that has been cross-connected via the FR/ATM PVC Service IWF cross-connect table will return the value zero when this object is read. In case of these interworked connections, the frPVCEndptAtmIwfConnIndex object must be accessed to select the entry in the FR/ATM PVC Service IWF cross-connect table. The value of this object is provided by the agent, after the associated entries in the frPVCConnectTable or frAtmIwfConnectionTable have been created." ::= { frPVCEndptEntry 10 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (30)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.44.1.3.1.1 frPVCEndptDLCIIndex 0 0 The value of this object is equal to the DLCI
    value for this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.2 frPVCEndptInMaxFrameSize 0 0 The value of this object is the size in octets of
    the largest frame relay information field for this
    PVC end-point in the ingress…
    1.3.6.1.2.1.10.44.1.3.1.3 frPVCEndptInBc 0 0 The value of this object is equal to the
    committed burst size (Bc) parameter (measured in
    bits) for this PVC end-point in the ing…
    1.3.6.1.2.1.10.44.1.3.1.4 frPVCEndptInBe 0 0 The value of this object is equal to the excess
    burst size (Be) parameter (measured in bits) for
    this PVC end-point in the ingres…
    1.3.6.1.2.1.10.44.1.3.1.5 frPVCEndptInCIR 0 0 The value of this object is equal to the
    committed information rate (CIR) parameter
    (measured in bits per second) for this PVC en…
    1.3.6.1.2.1.10.44.1.3.1.6 frPVCEndptOutMaxFrameSize 0 0 The value of this object is the size in octets of
    the largest frame relay information field for this
    PVC end-point in the egress …
    1.3.6.1.2.1.10.44.1.3.1.7 frPVCEndptOutBc 0 0 The value of this object is equal to the
    committed burst size (Bc) parameter (measured in
    bits) for this PVC end-point in the egr…
    1.3.6.1.2.1.10.44.1.3.1.8 frPVCEndptOutBe 0 0 The value of this object is equal to the excess
    burst size (Be) parameter (measured in bits) for
    this PVC end-point in the egress…
    1.3.6.1.2.1.10.44.1.3.1.9 frPVCEndptOutCIR 0 0 The value of this object is equal to the
    committed information rate (CIR) parameter
    (measured in bits per second) for this PVC en…
    1.3.6.1.2.1.10.44.1.3.1.11 frPVCEndptRowStatus 0 0 This object is used to create new rows in this
    table, modify existing rows, and to delete
    existing rows. To create a new PVC, th…
    1.3.6.1.2.1.10.44.1.3.1.12 frPVCEndptRcvdSigStatus 0 0 The value of this object identifies the PVC
    status received via the local in-channel signaling
    procedures for this PVC end-point.…
    1.3.6.1.2.1.10.44.1.3.1.13 frPVCEndptInFrames 0 0 The number of frames received by the network
    (ingress) for this PVC end-point. This includes
    any frames discarded by the network …
    1.3.6.1.2.1.10.44.1.3.1.14 frPVCEndptOutFrames 0 0 The number of frames sent by the network (egress)
    regardless of whether they are Bc or Be frames for
    this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.15 frPVCEndptInDEFrames 0 0 The number of frames received by the network
    (ingress) with the DE bit set to (1) for this PVC
    end-point.
    1.3.6.1.2.1.10.44.1.3.1.16 frPVCEndptInExcessFrames 0 0 The number of frames received by the network
    (ingress) for this PVC end-point which were
    treated as excess traffic. Frames which…
    1.3.6.1.2.1.10.44.1.3.1.17 frPVCEndptOutExcessFrames 0 0 The number of frames sent by the network (egress)
    for this PVC end-point which were treated as
    excess traffic. (The DE bit may b…
    1.3.6.1.2.1.10.44.1.3.1.18 frPVCEndptInDiscards 0 0 The number of frames received by the the network
    (ingress) that were discarded due to traffic
    enforcement for this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.19 frPVCEndptInOctets 0 0 The number of octets received by the network
    (ingress) for this PVC end-point. This counter
    should only count octets from the be…
    1.3.6.1.2.1.10.44.1.3.1.20 frPVCEndptOutOctets 0 0 The number of octets sent by the network (egress)
    for this PVC end-point. This counter should only
    count octets from the beginni…
    1.3.6.1.2.1.10.44.1.3.1.21 frPVCEndptInDiscardsDESet 0 0 The number of frames received by the network
    (ingress) that were discarded with the DE bit set
    due to traffic enforcement for thi…
    1.3.6.1.2.1.10.44.1.3.1.22 frPVCEndptInFramesFECNSet 0 0 The number of frames received by the network
    (ingress) that have the FECN bit set for this PVC
    end-point.
    1.3.6.1.2.1.10.44.1.3.1.23 frPVCEndptOutFramesFECNSet 0 0 The number of frames sent by the network (egress)
    that have the FECN bit set for this PVC end-
    point.
    1.3.6.1.2.1.10.44.1.3.1.24 frPVCEndptInFramesBECNSet 0 0 The number of frames received by the network
    (ingress) that have the BECN bit set for this PVC
    end-point.
    1.3.6.1.2.1.10.44.1.3.1.25 frPVCEndptOutFramesBECNSet 0 0 The number of frames sent by the network (egress)
    that have the BECN bit set for this PVC end-
    point.
    1.3.6.1.2.1.10.44.1.3.1.26 frPVCEndptInCongDiscards 0 0 The number of frames received by the network
    (ingress) that were discarded due to input buffer
    congestion, rather than traffic en…
    1.3.6.1.2.1.10.44.1.3.1.27 frPVCEndptInDECongDiscards 0 0 The number of frames counted by
    frPVCEndptInCongDiscards with the DE bit set to
    (1).
    1.3.6.1.2.1.10.44.1.3.1.28 frPVCEndptOutCongDiscards 0 0 The number of frames sent by the network (egress)
    that were discarded due to output buffer
    congestion for this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.29 frPVCEndptOutDECongDiscards 0 0 The number of frames counted by
    frPVCEndptOutCongDiscards with the DE bit set to
    (1).
    1.3.6.1.2.1.10.44.1.3.1.30 frPVCEndptOutDEFrames 0 0 The number of frames sent by the network (egress)
    with the DE bit set to (1) for this PVC end-
    point.
    1.3.6.1.2.1.10.44.1.3.1.31 frPVCEndptAtmIwfConnIndex 0 0 This object contains the index value of the
    FR/ATM cross-connect table entry used to link the
    frame relay PVC with an ATM PVC.

    Eac…