Reference record for OID 1.3.6.1.2.1.10.44.1.3.1.12



parent
1.3.6.1.2.1.10.44.1.3.1 (frPVCEndptEntry)
node code
12
node name
frPVCEndptRcvdSigStatus
dot oid
1.3.6.1.2.1.10.44.1.3.1.12
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptRcvdSigStatus(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptRcvdSigStatus(12)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptRcvdSigStatus(12)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptRcvdSigStatus(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptRcvdSigStatus(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) frnetservMIB(44) frnetservObjects(1) frPVCEndptTable(3) frPVCEndptEntry(1) frPVCEndptRcvdSigStatus(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptRcvdSigStatus
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptRcvdSigStatus
  • /iso/org/dod/internet/mgmt/mib-2/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptRcvdSigStatus
  • /iso/org/dod/internet/mgmt/mib/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptRcvdSigStatus
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptRcvdSigStatus
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/frnetservMIB/frnetservObjects/frPVCEndptTable/frPVCEndptEntry/frPVCEndptRcvdSigStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/44/1/3/1/12

    Description by oid_info

    frPVCEndptRcvdSigStatus OBJECT-TYPE SYNTAX INTEGER {
    deleted(1),
    active(2),
    inactive(3),
    none(4)
    }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
    "The value of this object identifies the PVC
    status received via the local in-channel signaling
    procedures for this PVC end-point. This object is
    only pertinent for interfaces that perform the
    bidirectional procedures.
    Each value has the following meaning:
    deleted(1): This PVC is not listed in the full
    status reports received from the
    user device. The object retains
    this value for as long as the PVC
    is not listed in the full status
    reports
    active(2): This PVC is reported as active, or
    operational, by the user device.
    inactive(3): This PVC is reported as inactive,
    or non-operational, by the user
    device.
    none(4): This interface is only using the
    network-side in-channel signaling
    procedures, so this object does
    not apply."

    View at oid-info.com

    Description by mibdepot

    The value of this object identifies the PVC
    status received via the local in-channel signaling
    procedures for this PVC end-point. This object is
    only pertinent for interfaces that perform the


    bidirectional procedures. For user-to-network
    network side procedures, the value of this object
    should be none.

    Parsed from file rfc1604.mib.txt
    Company: None
    Module: FRNETSERV-MIB

    Description by circitor

    The value of this object identifies the PVC
    status received via the local in-channel signaling

    procedures for this PVC end-point. This object is
    only pertinent for interfaces that perform the
    bidirectional procedures.

    Each value has the following meaning:
    deleted(1): This PVC is not listed in the full
    status reports received from the
    user device. The object retains
    this value for as long as the PVC
    is not listed in the full status
    reports

    active(2): This PVC is reported as active, or
    operational, by the user device.

    inactive(3): This PVC is reported as inactive,
    or non-operational, by the user
    device.

    none(4): This interface is only using the
    network-side in-channel signaling
    procedures, so this object does
    not apply.

    Parsed from file FRNETSERV-MIB.mib
    Module: FRNETSERV-MIB

    Information by oid_info

    Automatically extracted from RFC2954

    Information by mibdepot

    frPVCEndptRcvdSigStatus OBJECT-TYPE SYNTAX INTEGER { deleted(1), active(2), inactive(3), none(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the PVC status received via the local in-channel signaling procedures for this PVC end-point. This object is only pertinent for interfaces that perform the bidirectional procedures. For user-to-network network side procedures, the value of this object should be none." ::= { frPVCEndptEntry 12 }

    Information by circitor

    frPVCEndptRcvdSigStatus OBJECT-TYPE SYNTAX INTEGER { deleted(1), active(2), inactive(3), none(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the PVC status received via the local in-channel signaling procedures for this PVC end-point. This object is only pertinent for interfaces that perform the bidirectional procedures. Each value has the following meaning: deleted(1): This PVC is not listed in the full status reports received from the user device. The object retains this value for as long as the PVC is not listed in the full status reports active(2): This PVC is reported as active, or operational, by the user device. inactive(3): This PVC is reported as inactive, or non-operational, by the user device. none(4): This interface is only using the network-side in-channel signaling procedures, so this object does not apply." ::= { frPVCEndptEntry 12 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (30)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.44.1.3.1.1 frPVCEndptDLCIIndex 0 0 The value of this object is equal to the DLCI
    value for this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.2 frPVCEndptInMaxFrameSize 0 0 The value of this object is the size in octets of
    the largest frame relay information field for this
    PVC end-point in the ingress…
    1.3.6.1.2.1.10.44.1.3.1.3 frPVCEndptInBc 0 0 The value of this object is equal to the
    committed burst size (Bc) parameter (measured in
    bits) for this PVC end-point in the ing…
    1.3.6.1.2.1.10.44.1.3.1.4 frPVCEndptInBe 0 0 The value of this object is equal to the excess
    burst size (Be) parameter (measured in bits) for
    this PVC end-point in the ingres…
    1.3.6.1.2.1.10.44.1.3.1.5 frPVCEndptInCIR 0 0 The value of this object is equal to the
    committed information rate (CIR) parameter
    (measured in bits per second) for this PVC en…
    1.3.6.1.2.1.10.44.1.3.1.6 frPVCEndptOutMaxFrameSize 0 0 The value of this object is the size in octets of
    the largest frame relay information field for this
    PVC end-point in the egress …
    1.3.6.1.2.1.10.44.1.3.1.7 frPVCEndptOutBc 0 0 The value of this object is equal to the
    committed burst size (Bc) parameter (measured in
    bits) for this PVC end-point in the egr…
    1.3.6.1.2.1.10.44.1.3.1.8 frPVCEndptOutBe 0 0 The value of this object is equal to the excess
    burst size (Be) parameter (measured in bits) for
    this PVC end-point in the egress…
    1.3.6.1.2.1.10.44.1.3.1.9 frPVCEndptOutCIR 0 0 The value of this object is equal to the
    committed information rate (CIR) parameter
    (measured in bits per second) for this PVC en…
    1.3.6.1.2.1.10.44.1.3.1.10 frPVCEndptConnectIdentifier 0 0 This object is used to associate PVC end-points
    as being part of one PVC segment connection. This
    value of this object is equal …
    1.3.6.1.2.1.10.44.1.3.1.11 frPVCEndptRowStatus 0 0 This object is used to create new rows in this
    table, modify existing rows, and to delete
    existing rows. To create a new PVC, th…
    1.3.6.1.2.1.10.44.1.3.1.13 frPVCEndptInFrames 0 0 The number of frames received by the network
    (ingress) for this PVC end-point. This includes
    any frames discarded by the network …
    1.3.6.1.2.1.10.44.1.3.1.14 frPVCEndptOutFrames 0 0 The number of frames sent by the network (egress)
    regardless of whether they are Bc or Be frames for
    this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.15 frPVCEndptInDEFrames 0 0 The number of frames received by the network
    (ingress) with the DE bit set to (1) for this PVC
    end-point.
    1.3.6.1.2.1.10.44.1.3.1.16 frPVCEndptInExcessFrames 0 0 The number of frames received by the network
    (ingress) for this PVC end-point which were
    treated as excess traffic. Frames which…
    1.3.6.1.2.1.10.44.1.3.1.17 frPVCEndptOutExcessFrames 0 0 The number of frames sent by the network (egress)
    for this PVC end-point which were treated as
    excess traffic. (The DE bit may b…
    1.3.6.1.2.1.10.44.1.3.1.18 frPVCEndptInDiscards 0 0 The number of frames received by the the network
    (ingress) that were discarded due to traffic
    enforcement for this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.19 frPVCEndptInOctets 0 0 The number of octets received by the network
    (ingress) for this PVC end-point. This counter
    should only count octets from the be…
    1.3.6.1.2.1.10.44.1.3.1.20 frPVCEndptOutOctets 0 0 The number of octets sent by the network (egress)
    for this PVC end-point. This counter should only
    count octets from the beginni…
    1.3.6.1.2.1.10.44.1.3.1.21 frPVCEndptInDiscardsDESet 0 0 The number of frames received by the network
    (ingress) that were discarded with the DE bit set
    due to traffic enforcement for thi…
    1.3.6.1.2.1.10.44.1.3.1.22 frPVCEndptInFramesFECNSet 0 0 The number of frames received by the network
    (ingress) that have the FECN bit set for this PVC
    end-point.
    1.3.6.1.2.1.10.44.1.3.1.23 frPVCEndptOutFramesFECNSet 0 0 The number of frames sent by the network (egress)
    that have the FECN bit set for this PVC end-
    point.
    1.3.6.1.2.1.10.44.1.3.1.24 frPVCEndptInFramesBECNSet 0 0 The number of frames received by the network
    (ingress) that have the BECN bit set for this PVC
    end-point.
    1.3.6.1.2.1.10.44.1.3.1.25 frPVCEndptOutFramesBECNSet 0 0 The number of frames sent by the network (egress)
    that have the BECN bit set for this PVC end-
    point.
    1.3.6.1.2.1.10.44.1.3.1.26 frPVCEndptInCongDiscards 0 0 The number of frames received by the network
    (ingress) that were discarded due to input buffer
    congestion, rather than traffic en…
    1.3.6.1.2.1.10.44.1.3.1.27 frPVCEndptInDECongDiscards 0 0 The number of frames counted by
    frPVCEndptInCongDiscards with the DE bit set to
    (1).
    1.3.6.1.2.1.10.44.1.3.1.28 frPVCEndptOutCongDiscards 0 0 The number of frames sent by the network (egress)
    that were discarded due to output buffer
    congestion for this PVC end-point.
    1.3.6.1.2.1.10.44.1.3.1.29 frPVCEndptOutDECongDiscards 0 0 The number of frames counted by
    frPVCEndptOutCongDiscards with the DE bit set to
    (1).
    1.3.6.1.2.1.10.44.1.3.1.30 frPVCEndptOutDEFrames 0 0 The number of frames sent by the network (egress)
    with the DE bit set to (1) for this PVC end-
    point.
    1.3.6.1.2.1.10.44.1.3.1.31 frPVCEndptAtmIwfConnIndex 0 0 This object contains the index value of the
    FR/ATM cross-connect table entry used to link the
    frame relay PVC with an ATM PVC.

    Eac…