frPVCEndptInOctets OBJECT-TYPE SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets received by the network
(ingress) for this PVC end-point. This counter
should only count octets from the beginning of the
frame relay header field to the end of user data.
If the network supporting frame relay can not
count octets, then this count should be an
approximation."
View at oid-info.com
The number of octets received by the network
(ingress) for this PVC end-point. This counter
should only count octets from the beginning of the
frame relay header field to the end of user data.
If the network supporting Frame Relay can not
count octets, then this count should be an
approximation.
Parsed from file rfc1604.mib.txt
Company: None
Module: FRNETSERV-MIB
The number of octets received by the network
(ingress) for this PVC end-point. This counter
should only count octets from the beginning of the
frame relay header field to the end of user data.
If the network supporting frame relay can not
count octets, then this count should be an
approximation.
Parsed from file FRNETSERV-MIB.mib
Module: FRNETSERV-MIB
Automatically extracted from RFC2954
frPVCEndptInOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets received by the network (ingress) for this PVC end-point. This counter should only count octets from the beginning of the frame relay header field to the end of user data. If the network supporting Frame Relay can not count octets, then this count should be an approximation." ::= { frPVCEndptEntry 19 }
frPVCEndptInOctets OBJECT-TYPE SYNTAX Counter32 UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets received by the network (ingress) for this PVC end-point. This counter should only count octets from the beginning of the frame relay header field to the end of user data. If the network supporting frame relay can not count octets, then this count should be an approximation." ::= { frPVCEndptEntry 19 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.44.1.3.1.1 | frPVCEndptDLCIIndex | 0 | 0 | The value of this object is equal to the DLCI value for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.2 | frPVCEndptInMaxFrameSize | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC end-point in the ingress… |
1.3.6.1.2.1.10.44.1.3.1.3 | frPVCEndptInBc | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC end-point in the ing… |
1.3.6.1.2.1.10.44.1.3.1.4 | frPVCEndptInBe | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC end-point in the ingres… |
1.3.6.1.2.1.10.44.1.3.1.5 | frPVCEndptInCIR | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC en… |
1.3.6.1.2.1.10.44.1.3.1.6 | frPVCEndptOutMaxFrameSize | 0 | 0 | The value of this object is the size in octets of the largest frame relay information field for this PVC end-point in the egress … |
1.3.6.1.2.1.10.44.1.3.1.7 | frPVCEndptOutBc | 0 | 0 | The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC end-point in the egr… |
1.3.6.1.2.1.10.44.1.3.1.8 | frPVCEndptOutBe | 0 | 0 | The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC end-point in the egress… |
1.3.6.1.2.1.10.44.1.3.1.9 | frPVCEndptOutCIR | 0 | 0 | The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC en… |
1.3.6.1.2.1.10.44.1.3.1.10 | frPVCEndptConnectIdentifier | 0 | 0 | This object is used to associate PVC end-points as being part of one PVC segment connection. This value of this object is equal … |
1.3.6.1.2.1.10.44.1.3.1.11 | frPVCEndptRowStatus | 0 | 0 | This object is used to create new rows in this table, modify existing rows, and to delete existing rows. To create a new PVC, th… |
1.3.6.1.2.1.10.44.1.3.1.12 | frPVCEndptRcvdSigStatus | 0 | 0 | The value of this object identifies the PVC status received via the local in-channel signaling procedures for this PVC end-point.… |
1.3.6.1.2.1.10.44.1.3.1.13 | frPVCEndptInFrames | 0 | 0 | The number of frames received by the network (ingress) for this PVC end-point. This includes any frames discarded by the network … |
1.3.6.1.2.1.10.44.1.3.1.14 | frPVCEndptOutFrames | 0 | 0 | The number of frames sent by the network (egress) regardless of whether they are Bc or Be frames for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.15 | frPVCEndptInDEFrames | 0 | 0 | The number of frames received by the network (ingress) with the DE bit set to (1) for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.16 | frPVCEndptInExcessFrames | 0 | 0 | The number of frames received by the network (ingress) for this PVC end-point which were treated as excess traffic. Frames which… |
1.3.6.1.2.1.10.44.1.3.1.17 | frPVCEndptOutExcessFrames | 0 | 0 | The number of frames sent by the network (egress) for this PVC end-point which were treated as excess traffic. (The DE bit may b… |
1.3.6.1.2.1.10.44.1.3.1.18 | frPVCEndptInDiscards | 0 | 0 | The number of frames received by the the network (ingress) that were discarded due to traffic enforcement for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.20 | frPVCEndptOutOctets | 0 | 0 | The number of octets sent by the network (egress) for this PVC end-point. This counter should only count octets from the beginni… |
1.3.6.1.2.1.10.44.1.3.1.21 | frPVCEndptInDiscardsDESet | 0 | 0 | The number of frames received by the network (ingress) that were discarded with the DE bit set due to traffic enforcement for thi… |
1.3.6.1.2.1.10.44.1.3.1.22 | frPVCEndptInFramesFECNSet | 0 | 0 | The number of frames received by the network (ingress) that have the FECN bit set for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.23 | frPVCEndptOutFramesFECNSet | 0 | 0 | The number of frames sent by the network (egress) that have the FECN bit set for this PVC end- point. |
1.3.6.1.2.1.10.44.1.3.1.24 | frPVCEndptInFramesBECNSet | 0 | 0 | The number of frames received by the network (ingress) that have the BECN bit set for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.25 | frPVCEndptOutFramesBECNSet | 0 | 0 | The number of frames sent by the network (egress) that have the BECN bit set for this PVC end- point. |
1.3.6.1.2.1.10.44.1.3.1.26 | frPVCEndptInCongDiscards | 0 | 0 | The number of frames received by the network (ingress) that were discarded due to input buffer congestion, rather than traffic en… |
1.3.6.1.2.1.10.44.1.3.1.27 | frPVCEndptInDECongDiscards | 0 | 0 | The number of frames counted by frPVCEndptInCongDiscards with the DE bit set to (1). |
1.3.6.1.2.1.10.44.1.3.1.28 | frPVCEndptOutCongDiscards | 0 | 0 | The number of frames sent by the network (egress) that were discarded due to output buffer congestion for this PVC end-point. |
1.3.6.1.2.1.10.44.1.3.1.29 | frPVCEndptOutDECongDiscards | 0 | 0 | The number of frames counted by frPVCEndptOutCongDiscards with the DE bit set to (1). |
1.3.6.1.2.1.10.44.1.3.1.30 | frPVCEndptOutDEFrames | 0 | 0 | The number of frames sent by the network (egress) with the DE bit set to (1) for this PVC end- point. |
1.3.6.1.2.1.10.44.1.3.1.31 | frPVCEndptAtmIwfConnIndex | 0 | 0 | This object contains the index value of the FR/ATM cross-connect table entry used to link the frame relay PVC with an ATM PVC. Eac… |