Reference record for OID 1.3.6.1.4.1.164.3.1.4.1.1.1.15



parent
1.3.6.1.4.1.164.3.1.4.1.1.1 (prtSInstEntry)
node code
15
node name
prtSParamStatus
dot oid
1.3.6.1.4.1.164.3.1.4.1.1.1.15
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) wanGen(1) prtWanGen(4) statPrtGen(1) prtSInstTable(1) prtSInstEntry(1) prtSParamStatus(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) wanGen(1) prtWanGen(4) statPrtGen(1) prtSInstTable(1) prtSInstEntry(1) prtSParamStatus(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) wanGen(1) prtWanGen(4) statPrtGen(1) prtSInstTable(1) prtSInstEntry(1) prtSParamStatus(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) wanGen(1) prtWanGen(4) statPrtGen(1) prtSInstTable(1) prtSInstEntry(1) prtSParamStatus(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) wanGen(1) prtWanGen(4) statPrtGen(1) prtSInstTable(1) prtSInstEntry(1) prtSParamStatus(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) wanGen(1) prtWanGen(4) statPrtGen(1) prtSInstTable(1) prtSInstEntry(1) prtSParamStatus(15)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/rad/radWan/wanGen/prtWanGen/statPrtGen/prtSInstTable/prtSInstEntry/prtSParamStatus
  • /iso/identified-organization/dod/internet/private/enterprises/rad/radWan/wanGen/prtWanGen/statPrtGen/prtSInstTable/prtSInstEntry/prtSParamStatus
  • /iso/org/dod/internet/private/enterprise/rad/radWan/wanGen/prtWanGen/statPrtGen/prtSInstTable/prtSInstEntry/prtSParamStatus
  • /iso/org/dod/internet/private/enterprises/rad/radWan/wanGen/prtWanGen/statPrtGen/prtSInstTable/prtSInstEntry/prtSParamStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/rad/radWan/wanGen/prtWanGen/statPrtGen/prtSInstTable/prtSInstEntry/prtSParamStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/rad/radWan/wanGen/prtWanGen/statPrtGen/prtSInstTable/prtSInstEntry/prtSParamStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/164/3/1/4/1/1/1/15

    Description by mibdepot

    This object indicates Status of parameters specific to the
    selected port.
    - For a port that has no special status or is supported
    by prtSExHsfStatTable - 1 Octet: 00hex

    - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet :
    Bit 7 (MSB)..Bit 2 = 0 (NA)
    Bit 1: Tx Signaling '1'=On ; '0'=Off
    Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off

    - For VC-2/R2(FXS) external ports - 1 Octet :
    Bit - 7 6 5 4 3 2 1 0
    |_| |_________|
    Call Call State
    Direction

    Bit 7 (MSB) and Bit 6 : Call Direction
    00 - Incoming
    01 - Outgoing
    Bit 5..Bit 0: Call State
    000000 - Idle
    000001 - Seized
    000010 - Both-Way Conflict
    000011 - Seizure Ack
    000100 - Answered
    000101 - Clear Backward
    000110 - Clear Forward
    000111 - Blocked
    001000 - Fault
    001001 - Fault 3
    001010 - Fault 4
    001011 - Fault 5
    001100 - Fault 6
    001101 - Fault 7

    - For ML-20 external port - 3 Octets :
    - 1 MS Octet will represent the Real Rate used:
    Bit - 7 6 5 4 3 2 1 0
    |___| |_______|
    spare Rate

    Valid values: 0..31, meaning 0..31x64Kbps
    Invalid values: 32..255.
    - 2 LS Octets will represent the Status of 7 Control
    Signals:
    Signal -
    Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
    Octet - 2 3 (LS)
    '
    Rest of the Signals (2 bits each) can have the following
    values:
    00=NA ; 01=unused ; 10=Off ; 11=On

    - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
    Bit - 7 6 5 4 3 2 1 0
    |___________|
    spare Mode of Operation

    Mode of Operation: '1'=Central ; '0'=Remote

    - For ACM external port - 1 Octet
    Bit - 7 6 5 4 3 2 1 0
    |_________|
    spare Alarm State

    Alarm State: according to bits 1,0:
    00=NA ; 01=unused ; 10=Off ; 11=On

    - For HS-U/1 external port - 1 Octet
    Bit 7 6 5 4 3 2 1 0 LSB
    |________| |__| |__|
    spare modem sync

    modem: 00 = other sync: 00 = not sync
    01 = unknown 01 = sync
    10 = ASMi-31/2 10 = reserved
    11 = reserved 11 = reserved

    - For MTML-2 external ports, MTML-E2 internal ports - 1 Octet :
    Bit 7 6 5 4 3 2 1 0 LSB
    |
    BERT State
    BERT State (Bit 0):
    0 = OFF (BERT is not running on this port or any of its TSs/Bits)
    1 = ON (BERT is running on this port OR on one of its TSs/Bits)

    Parsed from file Rad0485.MIB.txt
    Company: None
    Module: RAD-MIB

    Description by circitor

    This object indicates Status of parameters specific to the
    selected port.
    - For a port that has no special status or is supported
    by prtSExHsfStatTable - 1 Octet: 00hex

    - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet :
    Bit 7 (MSB)..Bit 2 = 0 (NA)
    Bit 1: Tx Signaling '1'=On ; '0'=Off
    Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off

    - For VC-2/R2(FXS) external ports - 1 Octet :
    Bit - 7 6 5 4 3 2 1 0
    |_| |_________|
    Call Call State
    Direction

    Bit 7 (MSB) and Bit 6 : Call Direction
    00 - Incoming
    01 - Outgoing
    Bit 5..Bit 0: Call State
    000000 - Idle
    000001 - Seized
    000010 - Both-Way Conflict
    000011 - Seizure Ack
    000100 - Answered
    000101 - Clear Backward
    000110 - Clear Forward
    000111 - Blocked
    001000 - Fault
    001001 - Fault 3
    001010 - Fault 4
    001011 - Fault 5
    001100 - Fault 6
    001101 - Fault 7

    - For ML-20 external port - 3 Octets :
    - 1 MS Octet will represent the Real Rate used:
    Bit - 7 6 5 4 3 2 1 0
    |___| |_______|
    spare Rate

    Valid values: 0..31, meaning 0..31x64Kbps
    Invalid values: 32..255.
    - 2 LS Octets will represent the Status of 7 Control
    Signals:
    Signal -
    Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
    Octet - 2 3 (LS)
    '
    Rest of the Signals (2 bits each) can have the following
    values:
    00=NA ; 01=unused ; 10=Off ; 11=On

    - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
    Bit - 7 6 5 4 3 2 1 0
    |___________|
    spare Mode of Operation

    Mode of Operation: '1'=Central ; '0'=Remote

    - For ACM external port - 1 Octet
    Bit - 7 6 5 4 3 2 1 0
    |_________|
    spare Alarm State

    Alarm State: according to bits 1,0:
    00=NA ; 01=unused ; 10=Off ; 11=On

    - For HS-U/1 external port - 1 Octet
    Bit 7 6 5 4 3 2 1 0 LSB
    |________| |__| |__|
    spare modem sync

    modem: 00 = other sync: 00 = not sync
    01 = unknown 01 = sync
    10 = ASMi-31/2 10 = reserved
    11 = reserved 11 = reserved

    - For MTML-2 external ports, MTML-E2 internal ports - 1 Octet :
    Bit 7 6 5 4 3 2 1 0 LSB
    |
    BERT State
    BERT State (Bit 0):
    0 = OFF (BERT is not running on this port or any of its TSs/Bits)
    1 = ON (BERT is running on this port OR on one of its TSs/Bits)

    Parsed from file RAD-MIB.mib
    Module: RAD-MIB

    Information by oid_info

    Vendor: Rad Data Communications Ltd.
    Module: DACS-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    prtSParamStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) ' Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2 external ports, MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits)" ::= { prtSInstEntry 15}

    Information by circitor

    prtSParamStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) ' Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2 external ports, MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits)" ::= { prtSInstEntry 15}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Brighitte Shalom

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Smadar Tauber

    Brothers (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.164.3.1.4.1.1.1.1 prtSInstSltIdx 0 0 This attribute indicates a unique number to identify the
    slot where the card is inserted.
    In the ?004 Unit the entries io6(10)..i…
    1.3.6.1.4.1.164.3.1.4.1.1.1.2 prtSInstPrtIdx 0 0 This attribute indicates a unique number to identify a port
    in a specific card.
    The valid ports depend on the installed card:
    the …
    1.3.6.1.4.1.164.3.1.4.1.1.1.3 prtSInstPrtType 0 0 This attribute describes the type of the designated port.
    In MX 3000 only external & internal options are used.
    All the other opt…
    1.3.6.1.4.1.164.3.1.4.1.1.1.4 prtSInstIfIndex 0 0 This attribute indicates the unique interface number
    assigned to the port. The specific interface of this
    attribute is the same…
    1.3.6.1.4.1.164.3.1.4.1.1.1.5 prtSActiveStatus 0 0 This attribute describes the activity status of the port.
    unknown(1) indicates that the information is not supported.
    notUsed(2) …
    1.3.6.1.4.1.164.3.1.4.1.1.1.6 prtSAlrStatus 0 0 Indicates the alarm state in the port(ch) agent level.
    This attribute will be set to:
    critical(7) - when there is at least one ac…
    1.3.6.1.4.1.164.3.1.4.1.1.1.7 prtSMaskedAlrStat 0 0 Indicates the alarm state in the port(ch) agent level,
    including Masked alarms.
    This attribute will be set to:
    critical(7) - when …
    1.3.6.1.4.1.164.3.1.4.1.1.1.8 prtSClearAlrCmd 0 0 Setting this attribute to on(3) enforces a clear operation
    of the alarm status events in the given port. The clear
    operation will…
    1.3.6.1.4.1.164.3.1.4.1.1.1.9 prtSTestMask 0 0 This is a mask which indicates which tests from the
    'prtSTstCmd' list are allowed for the requested port.
    If a specific test is a…
    1.3.6.1.4.1.164.3.1.4.1.1.1.10 prtSTstCmd 0 0 Setting this attribute to any of the above values will
    initiate a test on the specific port if the operation is
    legal. If the ope…
    1.3.6.1.4.1.164.3.1.4.1.1.1.11 prtSTstDuration 0 0 This attribute indicates the maximum duration of executing
    a test on the specific port. This entry applies to all the
    test operat…
    1.3.6.1.4.1.164.3.1.4.1.1.1.12 prtSBertClrCmd 0 0 Setting this attribute initiates bert count clear operation.
    It is valid only when bert test is active on the specific
    port.
    1.3.6.1.4.1.164.3.1.4.1.1.1.13 prtSBertTstRslt 0 0 This attribute indicates the number of Bit Error Rate
    indicated during the BERT operation.
    It is valid only when bert test is act…
    1.3.6.1.4.1.164.3.1.4.1.1.1.14 prtSInterfaceType 0 0 This attribute indicates a unique HW interface type of the
    selected port.