Vendor: SALIX Technologies, Inc.
Module: SALIX-HNE-MIB
[Automatically extracted from oidview.com]
hneSystemSync OBJECT IDENTIFIER ::= { hneSystem 2 }
hneSystemSync OBJECT IDENTIFIER ::= { hneSystem 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.1 | hneSysSyncTimingMode | 1 | 1 | An identification of the source from which timing is derived by the working sync module within the HNE. Possible values are: int… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.2 | hneSysSyncPrimaryRefLine | 1 | 1 | The interface index of the primary physical line termination point (SONET line) from which the sync module can derive timing. Thi… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.3 | hneSysSyncSecondaryRefLine | 1 | 1 | The interface index of the secondary physical line termination point (SONET line) from which the sync module can derive timing. T… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.4 | hneSysSyncRevertiveSwitch | 1 | 1 | Indication of whether or not the active reference should revert to primary if that reference becomes available after a failure is… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.5 | hneSysSyncClockMode | 1 | 1 | Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's … |
1.3.6.1.4.1.2158.3.1.1.1.1.2.6 | hneSysSyncConfiguredActiveRef | 1 | 1 | The configured active reference line from which the sync module should deriving its timing. This object is relevant if the hneSy… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.7 | hneSysSyncAutoRefSwitch | 1 | 1 | Indication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - A… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.8 | hneSysSyncFreeRunAlarm | 1 | 1 | Indication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disab… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.9 | hneSysSyncWorking | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to … |
1.3.6.1.4.1.2158.3.1.1.1.1.2.10 | hneSysSyncProtect | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 in… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.11 | hneSysSyncPrimaryRefLineState | 1 | 1 | This variable indicates the state of the primary reference line termination point (SONET line) to be used as a timing source by t… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.12 | hneSysSyncSecondaryRefLineState | 1 | 1 | This variable indicates the state of the secondary reference line termination point (SONET line) to be used as a timing source by… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.13 | hneSysSyncCurrentActiveRef | 1 | 1 | Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the hneSys… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.14 | hneSysSyncForcedState | 1 | 1 | This variable indicates the state of the sync module with regard to switching between the configured active reference, the value … |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.1 | hneSystemHost | 0 | 0 | None |
1.3.6.1.4.1.2158.3.1.1.1.1.3 | hneSystemHsf | 2 | 4 | None |