Indication of the active reference line from which the sync
module is deriving its timing. This object is relevant if the
hneSysSyncTimingMode is set to 'line' or 'external'. The
value of this variable can differ from the
'hneSysSyncConfiguredActiveRef' if the sync module determine an
error condition with the 'hneSysSyncConfiguredActiveRef' and
has switched to using another SONET line as the active reference.
primary(1) - The hneSysSyncPrimaryRefLine is the current
active reference line
secondary (2) - The hneSysSyncSecondaryRefLine is the current
active reference line
Parsed from file HNE.MI2.txt
Company: None
Module: SALIX-HNE-MIB
Indication of the active reference line from which the sync
module is deriving its timing. This object is relevant if the
hneSysSyncTimingMode is set to 'line' or 'external'. The
value of this variable can differ from the
'hneSysSyncConfiguredActiveRef' if the sync module determine an
error condition with the 'hneSysSyncConfiguredActiveRef' and
has switched to using another SONET line as the active reference.
primary(1) - The hneSysSyncPrimaryRefLine is the current
active reference line
secondary (2) - The hneSysSyncSecondaryRefLine is the current
active reference line
Parsed from file SALIX-HNE-MIB.mib
Module: SALIX-HNE-MIB
Vendor: SALIX Technologies, Inc.
Module: SALIX-HNE-MIB
[Automatically extracted from oidview.com]
hneSysSyncCurrentActiveRef OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the hneSysSyncTimingMode is set to 'line' or 'external'. The value of this variable can differ from the 'hneSysSyncConfiguredActiveRef' if the sync module determine an error condition with the 'hneSysSyncConfiguredActiveRef' and has switched to using another SONET line as the active reference. primary(1) - The hneSysSyncPrimaryRefLine is the current active reference line secondary (2) - The hneSysSyncSecondaryRefLine is the current active reference line" ::= { hneSystemSync 13 }
hneSysSyncCurrentActiveRef OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the hneSysSyncTimingMode is set to 'line' or 'external'. The value of this variable can differ from the 'hneSysSyncConfiguredActiveRef' if the sync module determine an error condition with the 'hneSysSyncConfiguredActiveRef' and has switched to using another SONET line as the active reference. primary(1) - The hneSysSyncPrimaryRefLine is the current active reference line secondary (2) - The hneSysSyncSecondaryRefLine is the current active reference line" ::= { hneSystemSync 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.13.0 | hneSysSyncCurrentActiveRef | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.1 | hneSysSyncTimingMode | 1 | 1 | An identification of the source from which timing is derived by the working sync module within the HNE. Possible values are: int… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.2 | hneSysSyncPrimaryRefLine | 1 | 1 | The interface index of the primary physical line termination point (SONET line) from which the sync module can derive timing. Thi… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.3 | hneSysSyncSecondaryRefLine | 1 | 1 | The interface index of the secondary physical line termination point (SONET line) from which the sync module can derive timing. T… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.4 | hneSysSyncRevertiveSwitch | 1 | 1 | Indication of whether or not the active reference should revert to primary if that reference becomes available after a failure is… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.5 | hneSysSyncClockMode | 1 | 1 | Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's … |
1.3.6.1.4.1.2158.3.1.1.1.1.2.6 | hneSysSyncConfiguredActiveRef | 1 | 1 | The configured active reference line from which the sync module should deriving its timing. This object is relevant if the hneSy… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.7 | hneSysSyncAutoRefSwitch | 1 | 1 | Indication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - A… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.8 | hneSysSyncFreeRunAlarm | 1 | 1 | Indication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disab… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.9 | hneSysSyncWorking | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to … |
1.3.6.1.4.1.2158.3.1.1.1.1.2.10 | hneSysSyncProtect | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 in… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.11 | hneSysSyncPrimaryRefLineState | 1 | 1 | This variable indicates the state of the primary reference line termination point (SONET line) to be used as a timing source by t… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.12 | hneSysSyncSecondaryRefLineState | 1 | 1 | This variable indicates the state of the secondary reference line termination point (SONET line) to be used as a timing source by… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.14 | hneSysSyncForcedState | 1 | 1 | This variable indicates the state of the sync module with regard to switching between the configured active reference, the value … |