Indication of the clock mode of the 'working' sync module.
freeRun(1) - mode in which the clock is synchronized to the
module's internal oscillator.
normal(2) - mode in which the clock is synchronized to an
external reference.
holdover(3) - mode in which the clock, after having been
synchronized to an external reference, loses that
reference and all other external references.
fastStart(4) - mode in which the clock is in the process of
synchronizing to a reference.
Parsed from file HNE.MI2.txt
Company: None
Module: SALIX-HNE-MIB
Indication of the clock mode of the 'working' sync module.
freeRun(1) - mode in which the clock is synchronized to the
module's internal oscillator.
normal(2) - mode in which the clock is synchronized to an
external reference.
holdover(3) - mode in which the clock, after having been
synchronized to an external reference, loses that
reference and all other external references.
fastStart(4) - mode in which the clock is in the process of
synchronizing to a reference.
Parsed from file SALIX-HNE-MIB.mib
Module: SALIX-HNE-MIB
Vendor: SALIX Technologies, Inc.
Module: SALIX-HNE-MIB
[Automatically extracted from oidview.com]
hneSysSyncClockMode OBJECT-TYPE SYNTAX INTEGER { freeRun(1), normal(2), holdover(3), fastStart(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's internal oscillator. normal(2) - mode in which the clock is synchronized to an external reference. holdover(3) - mode in which the clock, after having been synchronized to an external reference, loses that reference and all other external references. fastStart(4) - mode in which the clock is in the process of synchronizing to a reference." ::= { hneSystemSync 5 }
hneSysSyncClockMode OBJECT-TYPE SYNTAX INTEGER { freeRun(1), normal(2), holdover(3), fastStart(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's internal oscillator. normal(2) - mode in which the clock is synchronized to an external reference. holdover(3) - mode in which the clock, after having been synchronized to an external reference, loses that reference and all other external references. fastStart(4) - mode in which the clock is in the process of synchronizing to a reference." ::= { hneSystemSync 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.5.0 | hneSysSyncClockMode | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.1 | hneSysSyncTimingMode | 1 | 1 | An identification of the source from which timing is derived by the working sync module within the HNE. Possible values are: int… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.2 | hneSysSyncPrimaryRefLine | 1 | 1 | The interface index of the primary physical line termination point (SONET line) from which the sync module can derive timing. Thi… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.3 | hneSysSyncSecondaryRefLine | 1 | 1 | The interface index of the secondary physical line termination point (SONET line) from which the sync module can derive timing. T… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.4 | hneSysSyncRevertiveSwitch | 1 | 1 | Indication of whether or not the active reference should revert to primary if that reference becomes available after a failure is… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.6 | hneSysSyncConfiguredActiveRef | 1 | 1 | The configured active reference line from which the sync module should deriving its timing. This object is relevant if the hneSy… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.7 | hneSysSyncAutoRefSwitch | 1 | 1 | Indication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - A… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.8 | hneSysSyncFreeRunAlarm | 1 | 1 | Indication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disab… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.9 | hneSysSyncWorking | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to … |
1.3.6.1.4.1.2158.3.1.1.1.1.2.10 | hneSysSyncProtect | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 in… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.11 | hneSysSyncPrimaryRefLineState | 1 | 1 | This variable indicates the state of the primary reference line termination point (SONET line) to be used as a timing source by t… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.12 | hneSysSyncSecondaryRefLineState | 1 | 1 | This variable indicates the state of the secondary reference line termination point (SONET line) to be used as a timing source by… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.13 | hneSysSyncCurrentActiveRef | 1 | 1 | Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the hneSys… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.14 | hneSysSyncForcedState | 1 | 1 | This variable indicates the state of the sync module with regard to switching between the configured active reference, the value … |