The entPhysicalIndex of the sync module plug-in unit that is
providing the system synchronizaton signal. Writing a new value
to this object, a value not equal to the current value, will:
- update the hneSysSyncProtect object with the current value
of the hneSysSyncWorking object and
- activate the specified sync module to start providing the
system synchronization signal.
A value of 0 indicates that there are no operational or not
installed sync modules in the system. Writing zero, an invalid
index, or the current value to this object will have no effect.
If the working sync module fails, the system will automatically
switch to the sync module specified in the hneSysSyncProtect
object.
Parsed from file HNE.MI2.txt
Company: None
Module: SALIX-HNE-MIB
The entPhysicalIndex of the sync module plug-in unit that is
providing the system synchronizaton signal. Writing a new value
to this object, a value not equal to the current value, will:
- update the hneSysSyncProtect object with the current value
of the hneSysSyncWorking object and
- activate the specified sync module to start providing the
system synchronization signal.
A value of 0 indicates that there are no operational or not
installed sync modules in the system. Writing zero, an invalid
index, or the current value to this object will have no effect.
If the working sync module fails, the system will automatically
switch to the sync module specified in the hneSysSyncProtect
object.
Parsed from file SALIX-HNE-MIB.mib
Module: SALIX-HNE-MIB
Vendor: SALIX Technologies, Inc.
Module: SALIX-HNE-MIB
[Automatically extracted from oidview.com]
hneSysSyncWorking OBJECT-TYPE SYNTAX PhysicalIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to this object, a value not equal to the current value, will: - update the hneSysSyncProtect object with the current value of the hneSysSyncWorking object and - activate the specified sync module to start providing the system synchronization signal. A value of 0 indicates that there are no operational or not installed sync modules in the system. Writing zero, an invalid index, or the current value to this object will have no effect. If the working sync module fails, the system will automatically switch to the sync module specified in the hneSysSyncProtect object." ::= { hneSystemSync 9 }
hneSysSyncWorking OBJECT-TYPE SYNTAX PhysicalIndex MAX-ACCESS read-write STATUS current DESCRIPTION "The entPhysicalIndex of the sync module plug-in unit that is providing the system synchronizaton signal. Writing a new value to this object, a value not equal to the current value, will: - update the hneSysSyncProtect object with the current value of the hneSysSyncWorking object and - activate the specified sync module to start providing the system synchronization signal. A value of 0 indicates that there are no operational or not installed sync modules in the system. Writing zero, an invalid index, or the current value to this object will have no effect. If the working sync module fails, the system will automatically switch to the sync module specified in the hneSysSyncProtect object." ::= { hneSystemSync 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.9.0 | hneSysSyncWorking | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2158.3.1.1.1.1.2.1 | hneSysSyncTimingMode | 1 | 1 | An identification of the source from which timing is derived by the working sync module within the HNE. Possible values are: int… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.2 | hneSysSyncPrimaryRefLine | 1 | 1 | The interface index of the primary physical line termination point (SONET line) from which the sync module can derive timing. Thi… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.3 | hneSysSyncSecondaryRefLine | 1 | 1 | The interface index of the secondary physical line termination point (SONET line) from which the sync module can derive timing. T… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.4 | hneSysSyncRevertiveSwitch | 1 | 1 | Indication of whether or not the active reference should revert to primary if that reference becomes available after a failure is… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.5 | hneSysSyncClockMode | 1 | 1 | Indication of the clock mode of the 'working' sync module. freeRun(1) - mode in which the clock is synchronized to the module's … |
1.3.6.1.4.1.2158.3.1.1.1.1.2.6 | hneSysSyncConfiguredActiveRef | 1 | 1 | The configured active reference line from which the sync module should deriving its timing. This object is relevant if the hneSy… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.7 | hneSysSyncAutoRefSwitch | 1 | 1 | Indication of automatic reference switching being enabled or disabled. true(1) - Auto reference switching is enabled false(2) - A… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.8 | hneSysSyncFreeRunAlarm | 1 | 1 | Indication of alarm associated with free-run mode being enabled or disabled. true(1) - Alarm is enabled false(2) - Alarm is disab… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.10 | hneSysSyncProtect | 1 | 1 | The entPhysicalIndex of the sync module plug-in unit that is protecting or on standby to the working sync module. A value of 0 in… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.11 | hneSysSyncPrimaryRefLineState | 1 | 1 | This variable indicates the state of the primary reference line termination point (SONET line) to be used as a timing source by t… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.12 | hneSysSyncSecondaryRefLineState | 1 | 1 | This variable indicates the state of the secondary reference line termination point (SONET line) to be used as a timing source by… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.13 | hneSysSyncCurrentActiveRef | 1 | 1 | Indication of the active reference line from which the sync module is deriving its timing. This object is relevant if the hneSys… |
1.3.6.1.4.1.2158.3.1.1.1.1.2.14 | hneSysSyncForcedState | 1 | 1 | This variable indicates the state of the sync module with regard to switching between the configured active reference, the value … |