The number of currently active PVCs on the node.
Parsed from file cascade.mib.txt
Company: None
Module: CASCADE-MIB
The number of currently active PVCs on the node.
Parsed from file CASCADE-MIB.mib
Module: CASCADE-MIB
Vendor: Cascade Communications Corp.
Module: CASCADE-MIB
[Automatically extracted from oidview.com]
nodeActivePvcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of currently active PVCs on the node." ::= { node 19 }
nodeActivePvcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of currently active PVCs on the node." ::= { node 19 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.277.1.3.19.0 | nodeActivePvcs | 0 | 0 | None |
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.277.1.3.1 | nodeIpAddr | 1 | 1 | The inband IP address of the node in the Cascade internal trunk IP network. |
1.3.6.1.4.1.277.1.3.2 | nodeLanIpAddr | 1 | 1 | The inband (Ethernet) IP address of the node for a NMS to access the node and the internal trunk IP network. |
1.3.6.1.4.1.277.1.3.3 | nodeNMSTable | 1 | 8 | A list of NMS entries. |
1.3.6.1.4.1.277.1.3.4 | nodeState | 1 | 1 | The state of the switch. The switch needs to await the state to be set to active before being fully operational after cold boot, … |
1.3.6.1.4.1.277.1.3.5 | nodePollStatus | 1 | 1 | The consolidated node status in response to keep-alive polls. It is an octet string of a proprietary format |
1.3.6.1.4.1.277.1.3.6 | nodeModel | 1 | 1 | The part number of the node. |
1.3.6.1.4.1.277.1.3.7 | nodeSerial | 1 | 1 | The serial number (i.e., Ethernet Addr) of the switch. |
1.3.6.1.4.1.277.1.3.8 | nodeSwRev | 1 | 1 | The software revision number (major.minor). |
1.3.6.1.4.1.277.1.3.9 | nodeHwRev | 1 | 1 | The hardware revision number (major.minor). |
1.3.6.1.4.1.277.1.3.10 | nodeEpromRev | 1 | 1 | The EPROM firmware revision number (major.minor). |
1.3.6.1.4.1.277.1.3.11 | nodeCpuUtil | 1 | 1 | The CPU utilization percentage for packet processing. |
1.3.6.1.4.1.277.1.3.12 | nodePsAStatus | 1 | 1 | The status of the power supply A. For a detailed explanation for the power supply being either in the down or marginal state, re… |
1.3.6.1.4.1.277.1.3.13 | nodePsBStatus | 1 | 1 | The status of the power supply B. For a detailed explanation for the power supply being either in the down or marginal state, re… |
1.3.6.1.4.1.277.1.3.14 | nodeFanTable | 1 | 4 | A list of fan entries. |
1.3.6.1.4.1.277.1.3.15 | nodeMemoryUtil | 1 | 1 | The percentage of system memory utilization on this intelligent card. |
1.3.6.1.4.1.277.1.3.16 | nodeMemoryUsage | 1 | 1 | The system memory utilization, in terms of free bytes, for this intelligent card. |
1.3.6.1.4.1.277.1.3.17 | nodeMaxFramesize | 1 | 1 | The maximum frame size supported by the node. The default is 4096. |
1.3.6.1.4.1.277.1.3.18 | nodeQOSPollTimer | 1 | 1 | The timer (seconds) for generating QOS polling packets. |
1.3.6.1.4.1.277.1.3.20 | nodeInactivePvcs | 1 | 1 | The number of currently inactive PVCs on the node. |
1.3.6.1.4.1.277.1.3.21 | nodePendingPvcs | 1 | 1 | The number of currently call pending PVCs on the node. |
1.3.6.1.4.1.277.1.3.22 | nodeInOctets | 1 | 1 | The total number of octets received on the node, including framing bytes. |
1.3.6.1.4.1.277.1.3.23 | nodeInPkts | 1 | 1 | The total number of packets received on the node. |
1.3.6.1.4.1.277.1.3.24 | nodeOutOctets | 1 | 1 | The total number of octets transmitted out of the node, including framing bytes. |
1.3.6.1.4.1.277.1.3.25 | nodeOutPkts | 1 | 1 | The total number of packets requested to be transmitted out of the node, including those that were discarded or not sent. |
1.3.6.1.4.1.277.1.3.26 | nodeSwFilename | 1 | 1 | Name of the file to be downloaded. |
1.3.6.1.4.1.277.1.3.27 | nodeRebootAfterLoad | 1 | 1 | Instructs the device to either automatically reboot after the successful scheduled download or not. |
1.3.6.1.4.1.277.1.3.28 | nodeSwToLoad | 1 | 1 | Instructs the device to initiate a software download (via tftp) request to the master management station after the specified time… |
1.3.6.1.4.1.277.1.3.29 | nodeSwLoadState | 1 | 1 | The state of the software download request. A download which is in either the PENDING, ACTIVE or FAILED state can be terminated … |
1.3.6.1.4.1.277.1.3.30 | nodePrFilename | 1 | 1 | Name of the PRAM image file to be downloaded. |
1.3.6.1.4.1.277.1.3.31 | nodePrToLoad | 1 | 1 | Instructs the device to initiate a PRAM image file download (via tftp) request to the master management station after the specifi… |
1.3.6.1.4.1.277.1.3.32 | nodePrLoadState | 1 | 1 | The state of the PRAM download request. A download which is in either the PENDING, ACTIVE or FAILED state can be terminated by s… |
1.3.6.1.4.1.277.1.3.33 | nodeToWarmboot | 1 | 1 | Instructs the switch to initiate a system warm boot after the specified time ticks have elapsed. A value of 0 indicates cancellat… |
1.3.6.1.4.1.277.1.3.34 | nodeToColdboot | 1 | 1 | Instructs the switch to initiate a system cold boot after the specified time ticks have elapsed. A value of 0 indicates cancellat… |
1.3.6.1.4.1.277.1.3.35 | nodeToRedundant | 1 | 1 | If redundancy is configured, instructs the node acting as Backup to disable the Active node and take over as the Active node. The… |
1.3.6.1.4.1.277.1.3.36 | nodeInitiateBulkStats | 1 | 1 | Initiates a Bulk Statistics poll and via TFTP, transfer the data to the specified IP address. |
1.3.6.1.4.1.277.1.3.37 | nodeDiagNonFatalSource | 1 | 1 | Source who reported last non-fatal error. |
1.3.6.1.4.1.277.1.3.38 | nodeDiagNonFatalTime | 1 | 1 | Time the last non-fatal error was reported. |
1.3.6.1.4.1.277.1.3.39 | nodeDiagNonFatalErrMajor | 1 | 1 | Major error code of last non-fatal error. |
1.3.6.1.4.1.277.1.3.40 | nodeDiagNonFatalErrMinor | 1 | 1 | Minor error code of last non-fatal error. |
1.3.6.1.4.1.277.1.3.41 | nodeDiagNonFatalStr | 1 | 1 | Ascii string describing last non-fatal error. |
1.3.6.1.4.1.277.1.3.42 | nodeDiagFatalSource | 1 | 1 | Source who reported last fatal error. |
1.3.6.1.4.1.277.1.3.43 | nodeDiagFatalTime | 1 | 1 | Time the last fatal error was reported. |
1.3.6.1.4.1.277.1.3.44 | nodeDiagFatalErrMajor | 1 | 1 | Major error code of last fatal error. |
1.3.6.1.4.1.277.1.3.45 | nodeDiagFatalErrMinor | 1 | 1 | Minor error code of last fatal error. |
1.3.6.1.4.1.277.1.3.46 | nodeDiagFatalStr | 1 | 1 | Ascii string describing last fatal error. |
1.3.6.1.4.1.277.1.3.47 | nodeDiagFatalReboots | 1 | 1 | Number of times the switch has re-booted since last fatal error was reported. |
1.3.6.1.4.1.277.1.3.48 | nodeDiagFatalAddress | 1 | 1 | Address switch was executing when it encountered fatal error. |
1.3.6.1.4.1.277.1.3.49 | nodeDiagBackgroundPasses | 1 | 1 | Number of passes made by the background diagnostics. |
1.3.6.1.4.1.277.1.3.50 | nodeDiagBackgroundFailures | 1 | 1 | Number of failures discovered by background diagnostics. |
1.3.6.1.4.1.277.1.3.51 | nodeDiagBackgroundSuccesses | 1 | 1 | Number of successful passes by background diagnostics. |
1.3.6.1.4.1.277.1.3.52 | nodeDiagLEDReset | 1 | 1 | Change the node state from marginal to active. Change the LED from yellow to green. |
1.3.6.1.4.1.277.1.3.53 | nodeDiagPowerExtensive | 1 | 1 | Should power on diagnostics do slower, extensive testing, or fast testing? |
1.3.6.1.4.1.277.1.3.54 | nodePortPoll | 1 | 1 | The consolidated port status in response to keep-alive polls. |
1.3.6.1.4.1.277.1.3.55 | nodeMaxTelnetConsole | 1 | 1 | The number of concurrent telnet consoles allowed. The default is 2. The maximum is 5. Set it 0 to disable telnet access. |
1.3.6.1.4.1.277.1.3.56 | nodeConsoleTimeout | 1 | 1 | Idle-logoff timer in minutes. The default is 5 minutes, and the maximum can be set is 60 minutes. To disable idle-logout, set thi… |
1.3.6.1.4.1.277.1.3.57 | nodeConsoleTable | 1 | 6 | A list of active consoles on the node, logged in through telnet or serial port. |
1.3.6.1.4.1.277.1.3.58 | nodePsADiagCode | 1 | 1 | The failure code of the power supply A. A non-zero value indicates one or more failures. Refer to the hardware manual for a des… |
1.3.6.1.4.1.277.1.3.59 | nodePsBDiagCode | 1 | 1 | The failure code of the power supply B. A non-zero value indicates one or more failures. Refer to the hardware manual for a des… |
1.3.6.1.4.1.277.1.3.60 | nodeFrameMemoryUtil | 1 | 1 | The percentage of frame memory utilization on this intelligent card. |
1.3.6.1.4.1.277.1.3.61 | nodeFrameMemoryUsage | 1 | 1 | The frame memory utilization, in terms of free bytes, for this intelligent card. |
1.3.6.1.4.1.277.1.3.62 | nodeCapability | 1 | 1 | The capability of this node. |
1.3.6.1.4.1.277.1.3.63 | nodeSvcLastCallFailure | 1 | 1 | A textual string describing the last call failure. |
1.3.6.1.4.1.277.1.3.64 | nodeRerouteDelay | 1 | 1 | The number of seconds delay between each reroute batch event. |
1.3.6.1.4.1.277.1.3.65 | nodeRerouteCount | 1 | 1 | The number of virtual circuits to request a reroute for duing a single reroute batch event. |
1.3.6.1.4.1.277.1.3.66 | nodeFileTransferRequest | 1 | 1 | This object is used to initiate file transfers to and from the switch. A management station can initiate a file transfer by settt… |
1.3.6.1.4.1.277.1.3.67 | nodeFileTransferStatus | 1 | 1 | The status of the file transfer. |
1.3.6.1.4.1.277.1.3.68 | nodeTime | 1 | 1 | The current wall-clock time that is set on the switch in Universal Coordinated Time (UCT). The value is the number of seconds si… |
1.3.6.1.4.1.277.1.3.69 | nodeBillingAPAddress | 1 | 1 | The IP Address of the Adjunct Billing Processor that is servicing this switch. |
... |