The state of the switch. The switch needs to await the
state to be set to active before being fully operational
after cold boot, when the NMS is reachable.
Parsed from file cascade.mib.txt
Company: None
Module: CASCADE-MIB
The state of the switch. The switch needs to await the
state to be set to active before being fully operational
after cold boot, when the NMS is reachable.
Parsed from file CASCADE-MIB.mib
Module: CASCADE-MIB
Vendor: Cascade Communications Corp.
Module: CASCADE-MIB
[Automatically extracted from oidview.com]
nodeState OBJECT-TYPE SYNTAX INTEGER { down (1), initializing (2), active (3), marginal (4), testing (5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of the switch. The switch needs to await the state to be set to active before being fully operational after cold boot, when the NMS is reachable." ::= { node 4 }
nodeState OBJECT-TYPE SYNTAX INTEGER { down (1), initializing (2), active (3), marginal (4), testing (5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of the switch. The switch needs to await the state to be set to active before being fully operational after cold boot, when the NMS is reachable." ::= { node 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.277.1.3.4.0 | nodeState | 0 | 0 | None |
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.277.1.3.1 | nodeIpAddr | 1 | 1 | The inband IP address of the node in the Cascade internal trunk IP network. |
1.3.6.1.4.1.277.1.3.2 | nodeLanIpAddr | 1 | 1 | The inband (Ethernet) IP address of the node for a NMS to access the node and the internal trunk IP network. |
1.3.6.1.4.1.277.1.3.3 | nodeNMSTable | 1 | 8 | A list of NMS entries. |
1.3.6.1.4.1.277.1.3.5 | nodePollStatus | 1 | 1 | The consolidated node status in response to keep-alive polls. It is an octet string of a proprietary format |
1.3.6.1.4.1.277.1.3.6 | nodeModel | 1 | 1 | The part number of the node. |
1.3.6.1.4.1.277.1.3.7 | nodeSerial | 1 | 1 | The serial number (i.e., Ethernet Addr) of the switch. |
1.3.6.1.4.1.277.1.3.8 | nodeSwRev | 1 | 1 | The software revision number (major.minor). |
1.3.6.1.4.1.277.1.3.9 | nodeHwRev | 1 | 1 | The hardware revision number (major.minor). |
1.3.6.1.4.1.277.1.3.10 | nodeEpromRev | 1 | 1 | The EPROM firmware revision number (major.minor). |
1.3.6.1.4.1.277.1.3.11 | nodeCpuUtil | 1 | 1 | The CPU utilization percentage for packet processing. |
1.3.6.1.4.1.277.1.3.12 | nodePsAStatus | 1 | 1 | The status of the power supply A. For a detailed explanation for the power supply being either in the down or marginal state, re… |
1.3.6.1.4.1.277.1.3.13 | nodePsBStatus | 1 | 1 | The status of the power supply B. For a detailed explanation for the power supply being either in the down or marginal state, re… |
1.3.6.1.4.1.277.1.3.14 | nodeFanTable | 1 | 4 | A list of fan entries. |
1.3.6.1.4.1.277.1.3.15 | nodeMemoryUtil | 1 | 1 | The percentage of system memory utilization on this intelligent card. |
1.3.6.1.4.1.277.1.3.16 | nodeMemoryUsage | 1 | 1 | The system memory utilization, in terms of free bytes, for this intelligent card. |
1.3.6.1.4.1.277.1.3.17 | nodeMaxFramesize | 1 | 1 | The maximum frame size supported by the node. The default is 4096. |
1.3.6.1.4.1.277.1.3.18 | nodeQOSPollTimer | 1 | 1 | The timer (seconds) for generating QOS polling packets. |
1.3.6.1.4.1.277.1.3.19 | nodeActivePvcs | 1 | 1 | The number of currently active PVCs on the node. |
1.3.6.1.4.1.277.1.3.20 | nodeInactivePvcs | 1 | 1 | The number of currently inactive PVCs on the node. |
1.3.6.1.4.1.277.1.3.21 | nodePendingPvcs | 1 | 1 | The number of currently call pending PVCs on the node. |
1.3.6.1.4.1.277.1.3.22 | nodeInOctets | 1 | 1 | The total number of octets received on the node, including framing bytes. |
1.3.6.1.4.1.277.1.3.23 | nodeInPkts | 1 | 1 | The total number of packets received on the node. |
1.3.6.1.4.1.277.1.3.24 | nodeOutOctets | 1 | 1 | The total number of octets transmitted out of the node, including framing bytes. |
1.3.6.1.4.1.277.1.3.25 | nodeOutPkts | 1 | 1 | The total number of packets requested to be transmitted out of the node, including those that were discarded or not sent. |
1.3.6.1.4.1.277.1.3.26 | nodeSwFilename | 1 | 1 | Name of the file to be downloaded. |
1.3.6.1.4.1.277.1.3.27 | nodeRebootAfterLoad | 1 | 1 | Instructs the device to either automatically reboot after the successful scheduled download or not. |
1.3.6.1.4.1.277.1.3.28 | nodeSwToLoad | 1 | 1 | Instructs the device to initiate a software download (via tftp) request to the master management station after the specified time… |
1.3.6.1.4.1.277.1.3.29 | nodeSwLoadState | 1 | 1 | The state of the software download request. A download which is in either the PENDING, ACTIVE or FAILED state can be terminated … |
1.3.6.1.4.1.277.1.3.30 | nodePrFilename | 1 | 1 | Name of the PRAM image file to be downloaded. |
1.3.6.1.4.1.277.1.3.31 | nodePrToLoad | 1 | 1 | Instructs the device to initiate a PRAM image file download (via tftp) request to the master management station after the specifi… |
1.3.6.1.4.1.277.1.3.32 | nodePrLoadState | 1 | 1 | The state of the PRAM download request. A download which is in either the PENDING, ACTIVE or FAILED state can be terminated by s… |
1.3.6.1.4.1.277.1.3.33 | nodeToWarmboot | 1 | 1 | Instructs the switch to initiate a system warm boot after the specified time ticks have elapsed. A value of 0 indicates cancellat… |
1.3.6.1.4.1.277.1.3.34 | nodeToColdboot | 1 | 1 | Instructs the switch to initiate a system cold boot after the specified time ticks have elapsed. A value of 0 indicates cancellat… |
1.3.6.1.4.1.277.1.3.35 | nodeToRedundant | 1 | 1 | If redundancy is configured, instructs the node acting as Backup to disable the Active node and take over as the Active node. The… |
1.3.6.1.4.1.277.1.3.36 | nodeInitiateBulkStats | 1 | 1 | Initiates a Bulk Statistics poll and via TFTP, transfer the data to the specified IP address. |
1.3.6.1.4.1.277.1.3.37 | nodeDiagNonFatalSource | 1 | 1 | Source who reported last non-fatal error. |
1.3.6.1.4.1.277.1.3.38 | nodeDiagNonFatalTime | 1 | 1 | Time the last non-fatal error was reported. |
1.3.6.1.4.1.277.1.3.39 | nodeDiagNonFatalErrMajor | 1 | 1 | Major error code of last non-fatal error. |
1.3.6.1.4.1.277.1.3.40 | nodeDiagNonFatalErrMinor | 1 | 1 | Minor error code of last non-fatal error. |
1.3.6.1.4.1.277.1.3.41 | nodeDiagNonFatalStr | 1 | 1 | Ascii string describing last non-fatal error. |
1.3.6.1.4.1.277.1.3.42 | nodeDiagFatalSource | 1 | 1 | Source who reported last fatal error. |
1.3.6.1.4.1.277.1.3.43 | nodeDiagFatalTime | 1 | 1 | Time the last fatal error was reported. |
1.3.6.1.4.1.277.1.3.44 | nodeDiagFatalErrMajor | 1 | 1 | Major error code of last fatal error. |
1.3.6.1.4.1.277.1.3.45 | nodeDiagFatalErrMinor | 1 | 1 | Minor error code of last fatal error. |
1.3.6.1.4.1.277.1.3.46 | nodeDiagFatalStr | 1 | 1 | Ascii string describing last fatal error. |
1.3.6.1.4.1.277.1.3.47 | nodeDiagFatalReboots | 1 | 1 | Number of times the switch has re-booted since last fatal error was reported. |
1.3.6.1.4.1.277.1.3.48 | nodeDiagFatalAddress | 1 | 1 | Address switch was executing when it encountered fatal error. |
1.3.6.1.4.1.277.1.3.49 | nodeDiagBackgroundPasses | 1 | 1 | Number of passes made by the background diagnostics. |
1.3.6.1.4.1.277.1.3.50 | nodeDiagBackgroundFailures | 1 | 1 | Number of failures discovered by background diagnostics. |
1.3.6.1.4.1.277.1.3.51 | nodeDiagBackgroundSuccesses | 1 | 1 | Number of successful passes by background diagnostics. |
1.3.6.1.4.1.277.1.3.52 | nodeDiagLEDReset | 1 | 1 | Change the node state from marginal to active. Change the LED from yellow to green. |
1.3.6.1.4.1.277.1.3.53 | nodeDiagPowerExtensive | 1 | 1 | Should power on diagnostics do slower, extensive testing, or fast testing? |
1.3.6.1.4.1.277.1.3.54 | nodePortPoll | 1 | 1 | The consolidated port status in response to keep-alive polls. |
... |