Reference record for OID 1.3.6.1.4.1.277.1.3.35


parent
1.3.6.1.4.1.277.1.3 (nodeBoardMismatch, node)
node code
35
node name
nodeToRedundant
dot oid
1.3.6.1.4.1.277.1.3.35
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) nodeBoardMismatch(3) nodeToRedundant(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) node(3) nodeToRedundant(35)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) nodeBoardMismatch(3) nodeToRedundant(35)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) node(3) nodeToRedundant(35)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) nodeBoardMismatch(3) nodeToRedundant(35)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) node(3) nodeToRedundant(35)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) nodeBoardMismatch(3) nodeToRedundant(35)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) node(3) nodeToRedundant(35)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cascade/cascfr/nodeBoardMismatch/nodeToRedundant
  • /iso/identified-organization/dod/internet/private/enterprise/cascade/cascfr/node/nodeToRedundant
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/cascade/cascfr/nodeBoardMismatch/nodeToRedundant
  • /iso/org/dod/internet/private/enterprise/cascade/cascfr/node/nodeToRedundant
  • /iso/org/dod/internet/private/enterprises/cascade/cascfr/nodeBoardMismatch/nodeToRedundant
  • /iso/org/dod/internet/private/enterprises/cascade/cascfr/node/nodeToRedundant
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cascade/cascfr/nodeBoardMismatch/nodeToRedundant
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cascade/cascfr/node/nodeToRedundant
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/277/1/3/35

    Description by mibdepot

    If redundancy is configured, instructs the node acting as Backup
    to disable the Active node and take over as the Active node.
    The disabling is initiated after the specified time ticks have
    elapsed. A value of 0 indicates cancellation of the previously
    scheduled request.

    Parsed from file cascade.mib.txt
    Company: None
    Module: CASCADE-MIB

    Description by circitor

    If redundancy is configured, instructs the node acting as Backup
    to disable the Active node and take over as the Active node.
    The disabling is initiated after the specified time ticks have
    elapsed. A value of 0 indicates cancellation of the previously
    scheduled request.

    Parsed from file CASCADE-MIB.mib
    Module: CASCADE-MIB

    Information by oid_info

    Vendor: Cascade Communications Corp.
    Module: CASCADE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    nodeToRedundant OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "If redundancy is configured, instructs the node acting as Backup to disable the Active node and take over as the Active node. The disabling is initiated after the specified time ticks have elapsed. A value of 0 indicates cancellation of the previously scheduled request." ::= { node 35 }

    Information by circitor

    nodeToRedundant OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "If redundancy is configured, instructs the node acting as Backup to disable the Active node and take over as the Active node. The disabling is initiated after the specified time ticks have elapsed. A value of 0 indicates cancellation of the previously scheduled request." ::= { node 35 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.277)

    Shue Chikong

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.277.1.3.35.0 nodeToRedundant 0 0 None

    Brothers (166)

    To many brothers! Only 100 nearest brothers are shown.

    OIDNameSub childrenSub Nodes TotalDescription
    ...
    1.3.6.1.4.1.277.1.3.1 nodeIpAddr 1 1 The inband IP address of the node in the Cascade internal
    trunk IP network.
    1.3.6.1.4.1.277.1.3.2 nodeLanIpAddr 1 1 The inband (Ethernet) IP address of the node for a NMS
    to access the node and the internal trunk IP network.
    1.3.6.1.4.1.277.1.3.3 nodeNMSTable 1 8 A list of NMS entries.
    1.3.6.1.4.1.277.1.3.4 nodeState 1 1 The state of the switch. The switch needs to await the
    state to be set to active before being fully operational
    after cold boot, …
    1.3.6.1.4.1.277.1.3.5 nodePollStatus 1 1 The consolidated node status in response to keep-alive polls.
    It is an octet string of a proprietary format
    1.3.6.1.4.1.277.1.3.6 nodeModel 1 1 The part number of the node.
    1.3.6.1.4.1.277.1.3.7 nodeSerial 1 1 The serial number (i.e., Ethernet Addr) of the switch.
    1.3.6.1.4.1.277.1.3.8 nodeSwRev 1 1 The software revision number (major.minor).
    1.3.6.1.4.1.277.1.3.9 nodeHwRev 1 1 The hardware revision number (major.minor).
    1.3.6.1.4.1.277.1.3.10 nodeEpromRev 1 1 The EPROM firmware revision number (major.minor).
    1.3.6.1.4.1.277.1.3.11 nodeCpuUtil 1 1 The CPU utilization percentage for packet processing.
    1.3.6.1.4.1.277.1.3.12 nodePsAStatus 1 1 The status of the power supply A. For a detailed explanation
    for the power supply being either in the down or marginal
    state, re…
    1.3.6.1.4.1.277.1.3.13 nodePsBStatus 1 1 The status of the power supply B. For a detailed explanation
    for the power supply being either in the down or marginal
    state, re…
    1.3.6.1.4.1.277.1.3.14 nodeFanTable 1 4 A list of fan entries.
    1.3.6.1.4.1.277.1.3.15 nodeMemoryUtil 1 1 The percentage of system memory utilization on this intelligent card.
    1.3.6.1.4.1.277.1.3.16 nodeMemoryUsage 1 1 The system memory utilization, in terms of free bytes, for
    this intelligent card.
    1.3.6.1.4.1.277.1.3.17 nodeMaxFramesize 1 1 The maximum frame size supported by the node.
    The default is 4096.
    1.3.6.1.4.1.277.1.3.18 nodeQOSPollTimer 1 1 The timer (seconds) for generating QOS polling packets.
    1.3.6.1.4.1.277.1.3.19 nodeActivePvcs 1 1 The number of currently active PVCs on the node.
    1.3.6.1.4.1.277.1.3.20 nodeInactivePvcs 1 1 The number of currently inactive PVCs on the node.
    1.3.6.1.4.1.277.1.3.21 nodePendingPvcs 1 1 The number of currently call pending PVCs on the node.
    1.3.6.1.4.1.277.1.3.22 nodeInOctets 1 1 The total number of octets received on the node, including
    framing bytes.
    1.3.6.1.4.1.277.1.3.23 nodeInPkts 1 1 The total number of packets received on the node.
    1.3.6.1.4.1.277.1.3.24 nodeOutOctets 1 1 The total number of octets transmitted out of the node,
    including framing bytes.
    1.3.6.1.4.1.277.1.3.25 nodeOutPkts 1 1 The total number of packets requested to be transmitted out
    of the node, including those that were discarded or not sent.
    1.3.6.1.4.1.277.1.3.26 nodeSwFilename 1 1 Name of the file to be downloaded.
    1.3.6.1.4.1.277.1.3.27 nodeRebootAfterLoad 1 1 Instructs the device to either automatically reboot after
    the successful scheduled download or not.
    1.3.6.1.4.1.277.1.3.28 nodeSwToLoad 1 1 Instructs the device to initiate a software download
    (via tftp) request to the master management station after
    the specified time…
    1.3.6.1.4.1.277.1.3.29 nodeSwLoadState 1 1 The state of the software download request. A download
    which is in either the PENDING, ACTIVE or FAILED state
    can be terminated …
    1.3.6.1.4.1.277.1.3.30 nodePrFilename 1 1 Name of the PRAM image file to be downloaded.
    1.3.6.1.4.1.277.1.3.31 nodePrToLoad 1 1 Instructs the device to initiate a PRAM image file download
    (via tftp) request to the master management station after
    the specifi…
    1.3.6.1.4.1.277.1.3.32 nodePrLoadState 1 1 The state of the PRAM download request. A download
    which is in either the PENDING, ACTIVE or FAILED state
    can be terminated by s…
    1.3.6.1.4.1.277.1.3.33 nodeToWarmboot 1 1 Instructs the switch to initiate a system warm boot after
    the specified time ticks have elapsed. A value of 0 indicates
    cancellat…
    1.3.6.1.4.1.277.1.3.34 nodeToColdboot 1 1 Instructs the switch to initiate a system cold boot after
    the specified time ticks have elapsed. A value of 0 indicates
    cancellat…
    1.3.6.1.4.1.277.1.3.36 nodeInitiateBulkStats 1 1 Initiates a Bulk Statistics poll and via TFTP, transfer the data
    to the specified IP address.
    1.3.6.1.4.1.277.1.3.37 nodeDiagNonFatalSource 1 1 Source who reported last non-fatal error.
    1.3.6.1.4.1.277.1.3.38 nodeDiagNonFatalTime 1 1 Time the last non-fatal error was reported.
    1.3.6.1.4.1.277.1.3.39 nodeDiagNonFatalErrMajor 1 1 Major error code of last non-fatal error.
    1.3.6.1.4.1.277.1.3.40 nodeDiagNonFatalErrMinor 1 1 Minor error code of last non-fatal error.
    1.3.6.1.4.1.277.1.3.41 nodeDiagNonFatalStr 1 1 Ascii string describing last non-fatal error.
    1.3.6.1.4.1.277.1.3.42 nodeDiagFatalSource 1 1 Source who reported last fatal error.
    1.3.6.1.4.1.277.1.3.43 nodeDiagFatalTime 1 1 Time the last fatal error was reported.
    1.3.6.1.4.1.277.1.3.44 nodeDiagFatalErrMajor 1 1 Major error code of last fatal error.
    1.3.6.1.4.1.277.1.3.45 nodeDiagFatalErrMinor 1 1 Minor error code of last fatal error.
    1.3.6.1.4.1.277.1.3.46 nodeDiagFatalStr 1 1 Ascii string describing last fatal error.
    1.3.6.1.4.1.277.1.3.47 nodeDiagFatalReboots 1 1 Number of times the switch has re-booted since last
    fatal error was reported.
    1.3.6.1.4.1.277.1.3.48 nodeDiagFatalAddress 1 1 Address switch was executing when it encountered fatal error.
    1.3.6.1.4.1.277.1.3.49 nodeDiagBackgroundPasses 1 1 Number of passes made by the background diagnostics.
    1.3.6.1.4.1.277.1.3.50 nodeDiagBackgroundFailures 1 1 Number of failures discovered by background diagnostics.
    1.3.6.1.4.1.277.1.3.51 nodeDiagBackgroundSuccesses 1 1 Number of successful passes by background diagnostics.
    1.3.6.1.4.1.277.1.3.52 nodeDiagLEDReset 1 1 Change the node state from marginal to active. Change the
    LED from yellow to green.
    1.3.6.1.4.1.277.1.3.53 nodeDiagPowerExtensive 1 1 Should power on diagnostics do slower, extensive testing,
    or fast testing?
    1.3.6.1.4.1.277.1.3.54 nodePortPoll 1 1 The consolidated port status in response to keep-alive polls.
    1.3.6.1.4.1.277.1.3.55 nodeMaxTelnetConsole 1 1 The number of concurrent telnet consoles allowed. The default
    is 2. The maximum is 5. Set it 0 to disable telnet access.
    1.3.6.1.4.1.277.1.3.56 nodeConsoleTimeout 1 1 Idle-logoff timer in minutes. The default is 5 minutes, and the
    maximum can be set is 60 minutes. To disable idle-logout, set
    thi…
    1.3.6.1.4.1.277.1.3.57 nodeConsoleTable 1 6 A list of active consoles on the node, logged in through telnet
    or serial port.
    1.3.6.1.4.1.277.1.3.58 nodePsADiagCode 1 1 The failure code of the power supply A. A non-zero value
    indicates one or more failures. Refer to the hardware
    manual for a des…
    1.3.6.1.4.1.277.1.3.59 nodePsBDiagCode 1 1 The failure code of the power supply B. A non-zero value
    indicates one or more failures. Refer to the hardware
    manual for a des…
    1.3.6.1.4.1.277.1.3.60 nodeFrameMemoryUtil 1 1 The percentage of frame memory utilization on this intelligent card.
    1.3.6.1.4.1.277.1.3.61 nodeFrameMemoryUsage 1 1 The frame memory utilization, in terms of free bytes, for
    this intelligent card.
    1.3.6.1.4.1.277.1.3.62 nodeCapability 1 1 The capability of this node.
    1.3.6.1.4.1.277.1.3.63 nodeSvcLastCallFailure 1 1 A textual string describing the last call failure.
    1.3.6.1.4.1.277.1.3.64 nodeRerouteDelay 1 1 The number of seconds delay between each reroute batch event.
    1.3.6.1.4.1.277.1.3.65 nodeRerouteCount 1 1 The number of virtual circuits to request a reroute for duing
    a single reroute batch event.
    1.3.6.1.4.1.277.1.3.66 nodeFileTransferRequest 1 1 This object is used to initiate file transfers to and from
    the switch. A management station can initiate a file transfer
    by settt…
    1.3.6.1.4.1.277.1.3.67 nodeFileTransferStatus 1 1 The status of the file transfer.
    1.3.6.1.4.1.277.1.3.68 nodeTime 1 1 The current wall-clock time that is set on the switch in
    Universal Coordinated Time (UCT). The value is the number
    of seconds si…
    1.3.6.1.4.1.277.1.3.69 nodeBillingAPAddress 1 1 The IP Address of the Adjunct Billing Processor that is
    servicing this switch.
    1.3.6.1.4.1.277.1.3.70 nodeBillingAPUsername 1 1 The Username of the account on the Adjunct Billing Processor
    to which usage data will be transferred via FTP.
    1.3.6.1.4.1.277.1.3.71 nodeBillingAPPassword 1 1 The Password corresponding to the account identified by
    nodeBillingAPUsername. A NULL string is returned when read.
    1.3.6.1.4.1.277.1.3.72 nodeBillingSwAPCommsFailures 1 1 The number of times that communication from the switch to the
    Adjunct Billing Processor has failed during the current
    aggregation…
    1.3.6.1.4.1.277.1.3.73 nodeBillingTable 1 22 A table of Billing System managable objects, indexed by
    service.
    1.3.6.1.4.1.277.1.3.74 nodeRerouteAlg 1 1 The number of seconds delay between each reroute batch event.
    1.3.6.1.4.1.277.1.3.75 nodeADTable 1 14 A list of Authentication Domain entries.
    1.3.6.1.4.1.277.1.3.76 nodeOamAlarmDisabled 1 1 If disabled then don't generate oam alarms for circuits that are
    down on this switch.
    1.3.6.1.4.1.277.1.3.77 nodeRefclocksrcTable 1 6 A list of generators (sources) for the system reference
    clock on the node. This reference clock is used by the clock
    generation u…
    1.3.6.1.4.1.277.1.3.78 nodeRefclockActiveSrc 1 1 The entry number of the active reference clock source in
    nodeRefclocksrcTable. If zero, the CGU is in free-running mode or
    holdov…
    1.3.6.1.4.1.277.1.3.79 nodeRefclockActiveCGUSlotId 1 1 The physical slot id of the current master CGU board.
    1.3.6.1.4.1.277.1.3.80 nodeRefclockActiveCGUMode 1 1 The clock mode of the current master CGU board.
    1.3.6.1.4.1.277.1.3.81 nodeInitiateImageBackup 1 1 When set, copy all of the runtime application images
    and configuration images to there corresponding backup
    locations on the hard…
    1.3.6.1.4.1.277.1.3.82 nodeImageBackupState 1 1 Provides the current state of the images backup
    operation.
    1.3.6.1.4.1.277.1.3.83 nodeInitiateImageRestore 1 1 When set, copy all of the runtime application images
    and configuration images from their BACKUP locations on
    the hard disk to the…
    1.3.6.1.4.1.277.1.3.84 nodeApplicationTable 1 5 A list of Application Image Descriptions.
    1.3.6.1.4.1.277.1.3.85 nodePrimarySyncRefAdminState 1 1 The requested primary clock synchronization reference
    source.
    ...