Reference record for OID 1.3.6.1.4.1.277.1.8.1.1.12



parent
1.3.6.1.4.1.277.1.8.1.1 (dsx1ConfigEntry, cascds1ConfigEntry)
node code
12
node names
  • dsx1TransmitClockSource
  • cascds1TransmitClockSource
  • dot oid
    1.3.6.1.4.1.277.1.8.1.1.12
    type
    OBJECT-TYPE
    asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) nodeSwDownloadFailed(8) dsx1ConfigTable(1) dsx1ConfigEntry(1) dsx1TransmitClockSource(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) nodeSwDownloadFailed(8) dsx1ConfigTable(1) dsx1ConfigEntry(1) cascds1TransmitClockSource(12)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) ds1(8) cascds1ConfigTable(1) cascds1ConfigEntry(1) dsx1TransmitClockSource(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cascade(277) cascfr(1) ds1(8) cascds1ConfigTable(1) cascds1ConfigEntry(1) cascds1TransmitClockSource(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) nodeSwDownloadFailed(8) dsx1ConfigTable(1) dsx1ConfigEntry(1) dsx1TransmitClockSource(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) nodeSwDownloadFailed(8) dsx1ConfigTable(1) dsx1ConfigEntry(1) cascds1TransmitClockSource(12)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) ds1(8) cascds1ConfigTable(1) cascds1ConfigEntry(1) dsx1TransmitClockSource(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cascade(277) cascfr(1) ds1(8) cascds1ConfigTable(1) cascds1ConfigEntry(1) cascds1TransmitClockSource(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cascade/cascfr/nodeSwDownloadFailed/dsx1ConfigTable/dsx1ConfigEntry/dsx1TransmitClockSource
  • /iso/identified-organization/dod/internet/private/enterprise/cascade/cascfr/nodeSwDownloadFailed/dsx1ConfigTable/dsx1ConfigEntry/cascds1TransmitClockSource
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/cascade/cascfr/ds1/cascds1ConfigTable/cascds1ConfigEntry/dsx1TransmitClockSource
  • /iso/org/dod/internet/private/enterprise/cascade/cascfr/ds1/cascds1ConfigTable/cascds1ConfigEntry/cascds1TransmitClockSource
  • /iso/org/dod/internet/private/enterprises/cascade/cascfr/nodeSwDownloadFailed/dsx1ConfigTable/dsx1ConfigEntry/dsx1TransmitClockSource
  • /iso/org/dod/internet/private/enterprises/cascade/cascfr/nodeSwDownloadFailed/dsx1ConfigTable/dsx1ConfigEntry/cascds1TransmitClockSource
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cascade/cascfr/ds1/cascds1ConfigTable/cascds1ConfigEntry/dsx1TransmitClockSource
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cascade/cascfr/ds1/cascds1ConfigTable/cascds1ConfigEntry/cascds1TransmitClockSource
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/277/1/8/1/1/12

    Description by mibdepot

    The source of Tranmit Clock.

    'loopTiming' indicates that the recovered re-
    ceive clock is used as the transmit clock.

    'localTiming' indicates that a local clock
    source is used.

    'throughTiming' indicates that recovered re-
    ceive clock from another interface is used as
    the transmit clock.

    Parsed from file cascade.mib.txt
    Company: None
    Module: CASCADE-MIB

    Description by circitor

    The source of Tranmit Clock.

    'loopTiming' indicates that the recovered re-
    ceive clock is used as the transmit clock.

    'localTiming' indicates that a local clock
    source is used.

    'throughTiming' indicates that recovered re-
    ceive clock from another interface is used as
    the transmit clock.

    Parsed from file CASCADE-MIB.mib
    Module: CASCADE-MIB

    Information by oid_info

    Vendor: Cascade Communications Corp.
    Module: CASCADE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    dsx1TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming (1), localTiming (2), throughTiming (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used. 'throughTiming' indicates that recovered re- ceive clock from another interface is used as the transmit clock." ::= { dsx1ConfigEntry 12 }

    Information by circitor

    dsx1TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming (1), localTiming (2), throughTiming (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The source of Tranmit Clock. 'loopTiming' indicates that the recovered re- ceive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used. 'throughTiming' indicates that recovered re- ceive clock from another interface is used as the transmit clock." ::= { dsx1ConfigEntry 12 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.277)

    Shue Chikong

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.277.1.8.1.1.1 dsx1SlotId, cascds1SlotId 0 0 The slot number of the corresponding DS1.
    1.3.6.1.4.1.277.1.8.1.1.2 dsx1PortId, cascds1PortId 0 0 The port number of the corresponding DS1
    on the board.
    1.3.6.1.4.1.277.1.8.1.1.3 dsx1TimeElapsed, cascds1TimeElapsed 0 0 The number of seconds that have elapsed since
    the beginning of the current error-measurement
    period.
    1.3.6.1.4.1.277.1.8.1.1.4 dsx1ValidIntervals, cascds1ValidIntervals 0 0 The number of previous intervals for which
    valid data was collected. The value will be 96
    unless the interface was brought o…
    1.3.6.1.4.1.277.1.8.1.1.5 dsx1LineType, cascds1LineType 0 0 This variable indicates the variety of DS1
    Line implementing this circuit. The type of
    circuit affects the number of bits…
    1.3.6.1.4.1.277.1.8.1.1.6 dsx1LineCoding, cascds1LineCoding 0 0 This variable describes the variety of Zero
    Code Suppression used on the link, which in
    turn affects a number of its chara…
    1.3.6.1.4.1.277.1.8.1.1.7 dsx1SendCode, cascds1SendCode 0 0 This variable indicates what type of code is
    being sent across the DS1 interface by the dev-
    ice. The values mean:

    dsx1SendNoCo…
    1.3.6.1.4.1.277.1.8.1.1.8 dsx1CircuitIdentifier, cascds1CircuitIdentifier 0 0 This variable contains the transmission
    vendor's circuit identifier, for the purpose of
    facilitating troubleshooting.
    1.3.6.1.4.1.277.1.8.1.1.9 dsx1LoopbackConfig, cascds1LoopbackConfig 0 0 This variable represents the loopback confi-
    guration of the DS1 interface. Agents support-
    ing read/write access should retur…
    1.3.6.1.4.1.277.1.8.1.1.10 dsx1LineStatus, cascds1LineStatus 0 0 This variable indicates the Line Status of the
    interface. It contains loopback, failure, re-
    ceived 'alarm' and transmitted 'a…
    1.3.6.1.4.1.277.1.8.1.1.11 dsx1SignalMode, cascds1SignalMode 0 0 'none' indicates that no bits are reserved for
    signaling on this channel.

    'robbedBit' indicates that T1 Robbed Bit Sig-
    naling is…
    1.3.6.1.4.1.277.1.8.1.1.13 dsx1Fdl, cascds1Fdl 0 0 This bitmap describes the use of the facili-
    ties data link, and is the sum of the capabili-
    ties:

    'other' indicates that a prot…
    1.3.6.1.4.1.277.1.8.1.1.14 dsx1FdlVersion, cascds1FdlVersion 0 0 The version of the Dallas FDL firmware