Configures whether the outlet group will load shed (turn off)
when the UPS is on battery and the remaining runtime is less
than the upsOutletGroupConfigLoadShedRuntimeRemaining OID
setting. The settings for
upsOutletGroupConfigLoadShedControlSkipOffDelay and
upsOutletGroupConfigLoadShedControlAutoRestart are valid for
this load shed condition.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Configures whether the outlet group will load shed (turn off)
when the UPS is on battery and the remaining runtime is less
than the upsOutletGroupConfigLoadShedRuntimeRemaining OID
setting. The settings for
upsOutletGroupConfigLoadShedControlSkipOffDelay and
upsOutletGroupConfigLoadShedControlAutoRestart are valid for
this load shed condition.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
upsOutletGroupConfigLoadShedControlRuntimeRemaining OBJECT-TYPE SYNTAX INTEGER { upsOutletGroupConfigDisableRuntimeRemainingLoadShed (1), upsOutletGroupConfigEnableRuntimeRemainingLoadShed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShedRuntimeRemaining OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition." ::= { upsOutletGroupConfigEntry 11 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
upsOutletGroupConfigLoadShedControlRuntimeRemaining OBJECT-TYPE SYNTAX INTEGER { upsOutletGroupConfigDisableRuntimeRemainingLoadShed (1), upsOutletGroupConfigEnableRuntimeRemainingLoadShed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShedRuntimeRemaining OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition." ::= { upsOutletGroupConfigEntry 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 | upsOutletGroupConfigIndex | 0 | 0 | The index to the outlet group entry. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 | upsOutletGroupConfigName | 0 | 0 | The name of the outlet group. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 | upsOutletGroupConfigPowerOnDelay | 0 | 0 | The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied.… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 | upsOutletGroupConfigPowerOffDelay | 0 | 0 | The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applie… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 | upsOutletGroupConfigRebootDuration | 0 | 0 | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turni… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 | upsOutletGroupConfigMinReturnRuntime | 0 | 0 | In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runti… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.7 | upsOutletGroupConfigOutletType | 0 | 0 | Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and m… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 | upsOutletGroupConfigLoadShedControlSkipOffDelay | 0 | 0 | Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situa… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 | upsOutletGroupConfigLoadShedControlAutoRestart | 0 | 0 | Configures whether the outlet group will automatically restart after a load shedding situation, where applicable. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 | upsOutletGroupConfigLoadShedControlTimeOnBattery | 0 | 0 | Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConf… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 | upsOutletGroupConfigLoadShedControlInOverload | 0 | 0 | Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutlet… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 | upsOutletGroupConfigLoadShedTimeOnBattery | 0 | 0 | When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by th… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 | upsOutletGroupConfigLoadShedRuntimeRemaining | 0 | 0 | When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletG… |