Reference record for OID 1.3.6.1.4.1.318.1.1.1.12.2.2.1.7



parent
1.3.6.1.4.1.318.1.1.1.12.2.2.1 (upsOutletGroupConfigEntry)
node code
7
node name
upsOutletGroupConfigOutletType
dot oid
1.3.6.1.4.1.318.1.1.1.12.2.2.1.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsOutletGroups(12) upsOutletGroupConfig(2) upsOutletGroupConfigTable(2) upsOutletGroupConfigEntry(1) upsOutletGroupConfigOutletType(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsOutletGroups(12) upsOutletGroupConfig(2) upsOutletGroupConfigTable(2) upsOutletGroupConfigEntry(1) upsOutletGroupConfigOutletType(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsOutletGroups(12) upsOutletGroupConfig(2) upsOutletGroupConfigTable(2) upsOutletGroupConfigEntry(1) upsOutletGroupConfigOutletType(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsOutletGroups(12) upsOutletGroupConfig(2) upsOutletGroupConfigTable(2) upsOutletGroupConfigEntry(1) upsOutletGroupConfigOutletType(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsOutletGroups(12) upsOutletGroupConfig(2) upsOutletGroupConfigTable(2) upsOutletGroupConfigEntry(1) upsOutletGroupConfigOutletType(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsOutletGroups(12) upsOutletGroupConfig(2) upsOutletGroupConfigTable(2) upsOutletGroupConfigEntry(1) upsOutletGroupConfigOutletType(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsOutletGroups/upsOutletGroupConfig/upsOutletGroupConfigTable/upsOutletGroupConfigEntry/upsOutletGroupConfigOutletType
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsOutletGroups/upsOutletGroupConfig/upsOutletGroupConfigTable/upsOutletGroupConfigEntry/upsOutletGroupConfigOutletType
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsOutletGroups/upsOutletGroupConfig/upsOutletGroupConfigTable/upsOutletGroupConfigEntry/upsOutletGroupConfigOutletType
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsOutletGroups/upsOutletGroupConfig/upsOutletGroupConfigTable/upsOutletGroupConfigEntry/upsOutletGroupConfigOutletType
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsOutletGroups/upsOutletGroupConfig/upsOutletGroupConfigTable/upsOutletGroupConfigEntry/upsOutletGroupConfigOutletType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsOutletGroups/upsOutletGroupConfig/upsOutletGroupConfigTable/upsOutletGroupConfigEntry/upsOutletGroupConfigOutletType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/1/12/2/2/1/7

    Description by mibdepot

    Getting this variable will return the type of outlet group.
    If present in the system, the main outlet group is
    'unswitched' and must be on in order for any of the switched
    outlet groups to be on. Conversely, if the main outlet group
    is off, all the switched outlet groups must also be off.
    Therefore, any commands made to the main outlet group that
    turn it off will also be applied to all switched outlet
    groups that are on, unless the state of a switched outlet
    group prevents it, in which case the command will fail.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Getting this variable will return the type of outlet group.
    If present in the system, the main outlet group is
    'unswitched' and must be on in order for any of the switched
    outlet groups to be on. Conversely, if the main outlet group
    is off, all the switched outlet groups must also be off.
    Therefore, any commands made to the main outlet group that
    turn it off will also be applied to all switched outlet
    groups that are on, unless the state of a switched outlet
    group prevents it, in which case the command will fail.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    upsOutletGroupConfigOutletType OBJECT-TYPE SYNTAX INTEGER { upsSwitchedOutletGroup (1), upsMainOutletGroup (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail." ::= { upsOutletGroupConfigEntry 7 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsOutletGroupConfigOutletType OBJECT-TYPE SYNTAX INTEGER { upsSwitchedOutletGroup (1), upsMainOutletGroup (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail." ::= { upsOutletGroupConfigEntry 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 upsOutletGroupConfigIndex 0 0 The index to the outlet group entry.
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 upsOutletGroupConfigName 0 0 The name of the outlet group.
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 upsOutletGroupConfigPowerOnDelay 0 0 The amount of time (seconds) the outlet group will delay
    powering on when the delayed on, reboot, or shutdown command is
    applied.…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 upsOutletGroupConfigPowerOffDelay 0 0 The amount of time (seconds) the outlet group will delay
    powering off when the delayed off, reboot, or shutdown command is
    applie…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 upsOutletGroupConfigRebootDuration 0 0 During a reboot sequence, power is turned off and then
    back on. This OID defines the amount of time to wait
    (seconds) after turni…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 upsOutletGroupConfigMinReturnRuntime 0 0 In an Outlet Group shutdown sequence, the Outlet Group cycles
    power off then on. This OID defines the minimum amount of UPS
    runti…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 upsOutletGroupConfigLoadShedControlSkipOffDelay 0 0 Configures whether the outlet group's off delay setting
    (upsOutletGroupConfigPowerOffDelay) will be used in a load
    shedding situa…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 upsOutletGroupConfigLoadShedControlAutoRestart 0 0 Configures whether the outlet group will automatically restart
    after a load shedding situation, where applicable.
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 upsOutletGroupConfigLoadShedControlTimeOnBattery 0 0 Configures whether the outlet group will load shed (turn off)
    after the UPS's time on battery has exceeded the
    upsOutletGroupConf…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 upsOutletGroupConfigLoadShedControlRuntimeRemaining 0 0 Configures whether the outlet group will load shed (turn off)
    when the UPS is on battery and the remaining runtime is less
    than t…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 upsOutletGroupConfigLoadShedControlInOverload 0 0 Configures whether the outlet group will load shed (turn off)
    when the UPS is in an overload condition. The setting for
    upsOutlet…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 upsOutletGroupConfigLoadShedTimeOnBattery 0 0 When the UPS has been on battery for more time than this
    value, the outlet group will turn off if this condition is
    enabled by th…
    1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 upsOutletGroupConfigLoadShedRuntimeRemaining 0 0 When the runtime remaining is less than this value, the outlet
    group will turn off if this condition is enabled by the
    upsOutletG…