Getting this variable will return the type of outlet group.
If present in the system, the main outlet group is
'unswitched' and must be on in order for any of the switched
outlet groups to be on. Conversely, if the main outlet group
is off, all the switched outlet groups must also be off.
Therefore, any commands made to the main outlet group that
turn it off will also be applied to all switched outlet
groups that are on, unless the state of a switched outlet
group prevents it, in which case the command will fail.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Getting this variable will return the type of outlet group.
If present in the system, the main outlet group is
'unswitched' and must be on in order for any of the switched
outlet groups to be on. Conversely, if the main outlet group
is off, all the switched outlet groups must also be off.
Therefore, any commands made to the main outlet group that
turn it off will also be applied to all switched outlet
groups that are on, unless the state of a switched outlet
group prevents it, in which case the command will fail.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
upsOutletGroupConfigOutletType OBJECT-TYPE SYNTAX INTEGER { upsSwitchedOutletGroup (1), upsMainOutletGroup (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail." ::= { upsOutletGroupConfigEntry 7 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
upsOutletGroupConfigOutletType OBJECT-TYPE SYNTAX INTEGER { upsSwitchedOutletGroup (1), upsMainOutletGroup (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail." ::= { upsOutletGroupConfigEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 | upsOutletGroupConfigIndex | 0 | 0 | The index to the outlet group entry. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 | upsOutletGroupConfigName | 0 | 0 | The name of the outlet group. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 | upsOutletGroupConfigPowerOnDelay | 0 | 0 | The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied.… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 | upsOutletGroupConfigPowerOffDelay | 0 | 0 | The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applie… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 | upsOutletGroupConfigRebootDuration | 0 | 0 | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turni… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 | upsOutletGroupConfigMinReturnRuntime | 0 | 0 | In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runti… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 | upsOutletGroupConfigLoadShedControlSkipOffDelay | 0 | 0 | Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situa… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 | upsOutletGroupConfigLoadShedControlAutoRestart | 0 | 0 | Configures whether the outlet group will automatically restart after a load shedding situation, where applicable. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 | upsOutletGroupConfigLoadShedControlTimeOnBattery | 0 | 0 | Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConf… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 | upsOutletGroupConfigLoadShedControlRuntimeRemaining | 0 | 0 | Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than t… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 | upsOutletGroupConfigLoadShedControlInOverload | 0 | 0 | Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutlet… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 | upsOutletGroupConfigLoadShedTimeOnBattery | 0 | 0 | When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by th… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 | upsOutletGroupConfigLoadShedRuntimeRemaining | 0 | 0 | When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletG… |