| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 |
upsOutletGroupConfigIndex | 0 | 0 |
The index to the outlet group entry. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 |
upsOutletGroupConfigName | 0 | 0 |
The name of the outlet group. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 |
upsOutletGroupConfigPowerOnDelay | 0 | 0 |
The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied.… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 |
upsOutletGroupConfigPowerOffDelay | 0 | 0 |
The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applie… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 |
upsOutletGroupConfigMinReturnRuntime | 0 | 0 |
In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runti… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.7 |
upsOutletGroupConfigOutletType | 0 | 0 |
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and m… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 |
upsOutletGroupConfigLoadShedControlSkipOffDelay | 0 | 0 |
Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situa… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 |
upsOutletGroupConfigLoadShedControlAutoRestart | 0 | 0 |
Configures whether the outlet group will automatically restart after a load shedding situation, where applicable. |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 |
upsOutletGroupConfigLoadShedControlTimeOnBattery | 0 | 0 |
Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConf… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 |
upsOutletGroupConfigLoadShedControlRuntimeRemaining | 0 | 0 |
Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than t… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 |
upsOutletGroupConfigLoadShedControlInOverload | 0 | 0 |
Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutlet… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 |
upsOutletGroupConfigLoadShedTimeOnBattery | 0 | 0 |
When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by th… |
| 1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 |
upsOutletGroupConfigLoadShedRuntimeRemaining | 0 | 0 |
When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletG… |