Configures whether the outlet group will automatically restart
after a load shedding situation, where applicable.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Configures whether the outlet group will automatically restart
after a load shedding situation, where applicable.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
upsOutletGroupConfigLoadShedControlAutoRestart OBJECT-TYPE SYNTAX INTEGER { upsOutletGroupConfigAutoRestart (1), upsOutletGroupConfigManualRestart (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configures whether the outlet group will automatically restart after a load shedding situation, where applicable." ::= { upsOutletGroupConfigEntry 9 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
upsOutletGroupConfigLoadShedControlAutoRestart OBJECT-TYPE SYNTAX INTEGER { upsOutletGroupConfigAutoRestart (1), upsOutletGroupConfigManualRestart (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configures whether the outlet group will automatically restart after a load shedding situation, where applicable." ::= { upsOutletGroupConfigEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 | upsOutletGroupConfigIndex | 0 | 0 | The index to the outlet group entry. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 | upsOutletGroupConfigName | 0 | 0 | The name of the outlet group. |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 | upsOutletGroupConfigPowerOnDelay | 0 | 0 | The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied.… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 | upsOutletGroupConfigPowerOffDelay | 0 | 0 | The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applie… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 | upsOutletGroupConfigRebootDuration | 0 | 0 | During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turni… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 | upsOutletGroupConfigMinReturnRuntime | 0 | 0 | In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runti… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.7 | upsOutletGroupConfigOutletType | 0 | 0 | Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and m… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 | upsOutletGroupConfigLoadShedControlSkipOffDelay | 0 | 0 | Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situa… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 | upsOutletGroupConfigLoadShedControlTimeOnBattery | 0 | 0 | Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConf… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 | upsOutletGroupConfigLoadShedControlRuntimeRemaining | 0 | 0 | Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than t… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 | upsOutletGroupConfigLoadShedControlInOverload | 0 | 0 | Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutlet… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 | upsOutletGroupConfigLoadShedTimeOnBattery | 0 | 0 | When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by th… |
1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 | upsOutletGroupConfigLoadShedRuntimeRemaining | 0 | 0 | When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletG… |