airFMSysStatus OBJECT IDENTIFIER ::= { airFMSystem 1 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
airFMSysStatus OBJECT IDENTIFIER ::= { airFMSystem 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.1.1 | airFMSysNumber | 1 | 1 | The number of the system within the group. A value of notApplicable indicates that this OID does not apply to this device due to … |
1.3.6.1.4.1.318.1.1.13.1.4.1.2 | airFMSysPresentStatus | 1 | 1 | The present mode of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configu… |
1.3.6.1.4.1.318.1.1.13.1.4.1.3 | airFMSysPresentRole | 1 | 1 | The present role of the System in the Group. A value of notApplicable indicates that this OID does not apply to this device due t… |
1.3.6.1.4.1.318.1.1.13.1.4.1.4 | airFMSysRunHours | 1 | 1 | The total number of hours the System has been contributing to environmental control. A value of -2147483648 indicates that this O… |
1.3.6.1.4.1.318.1.1.13.1.4.1.5 | airFMSysCoilFluidTempC | 1 | 1 | The temperature of the coolant at the fluid coil inlet. Measured in degrees Celsius. A value of -2147483648 indicates that this … |
1.3.6.1.4.1.318.1.1.13.1.4.1.6 | airFMSysCoilFluidTempF | 1 | 1 | The temperature of the coolant at the fluid coil inlet. Measured in degrees Fahrenheit. A value of -2147483648 indicates that th… |
1.3.6.1.4.1.318.1.1.13.1.4.1.7 | airFMSysHotWaterTempC | 1 | 1 | The hot water temperature. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this dev… |
1.3.6.1.4.1.318.1.1.13.1.4.1.8 | airFMSysHotWaterTempF | 1 | 1 | The hot water temperature. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this … |
1.3.6.1.4.1.318.1.1.13.1.4.1.9 | airFMSysAvgReturnTempC | 1 | 1 | The average return temperature calculated from all present modules. Measured in tenths of degrees Celsius. A value of -2147483648 … |
1.3.6.1.4.1.318.1.1.13.1.4.1.10 | airFMSysAvgReturnTempF | 1 | 1 | The average return temperature calculated from all present modules. Measured in tenths of degrees Fahrenheit. A value of -21474836… |
1.3.6.1.4.1.318.1.1.13.1.4.1.11 | airFMSysAvgReturnHum | 1 | 1 | The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicat… |
1.3.6.1.4.1.318.1.1.13.1.4.1.12 | airFMSysAvgRemoteTempC | 1 | 1 | The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -214748… |
1.3.6.1.4.1.318.1.1.13.1.4.1.13 | airFMSysAvgRemoteTempF | 1 | 1 | The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147… |
1.3.6.1.4.1.318.1.1.13.1.4.1.14 | airFMSysAvgRemoteHum | 1 | 1 | The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicat… |
1.3.6.1.4.1.318.1.1.13.1.4.1.15 | airFMSysMaxRemoteTempC | 1 | 1 | The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648… |
1.3.6.1.4.1.318.1.1.13.1.4.1.16 | airFMSysMaxRemoteTempF | 1 | 1 | The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483… |
1.3.6.1.4.1.318.1.1.13.1.4.1.17 | airFMSysMinRemoteTempC | 1 | 1 | The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648… |
1.3.6.1.4.1.318.1.1.13.1.4.1.18 | airFMSysMinRemoteTempF | 1 | 1 | The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483… |
1.3.6.1.4.1.318.1.1.13.1.4.1.19 | airFMSysTempCtrlMethod | 1 | 1 | The method of environment temperature control selected to regulate the temperature. A value of notApplicable indicates that this … |
1.3.6.1.4.1.318.1.1.13.1.4.1.20 | airFMSysActualTempCtrlMethod | 1 | 1 | The actual method of environment temperature control being used to regulate the temperature. A value of notApplicable indicates t… |
1.3.6.1.4.1.318.1.1.13.1.4.1.21 | airFMSysHumCtrlMethod | 1 | 1 | The method of environment humidity control selected to regulate the humidity. A value of notApplicable indicates that this OID do… |
1.3.6.1.4.1.318.1.1.13.1.4.1.22 | airFMSysActualHumCtrlMethod | 1 | 1 | The actual method of environment humidity control being used to regulate the humidity. A value of notApplicable indicates that th… |
1.3.6.1.4.1.318.1.1.13.1.4.1.23 | airFMSysCtrlTempC | 1 | 1 | The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees… |
1.3.6.1.4.1.318.1.1.13.1.4.1.24 | airFMSysCtrlTempF | 1 | 1 | The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees… |
1.3.6.1.4.1.318.1.1.13.1.4.1.25 | airFMSysCtrlHum | 1 | 1 | The system environmental control air humidity from the sensor denoted by airFMSysActualHumCtrl. Measured in percent relative humi… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.2 | airFMSysDemands | 14 | 28 | None |
1.3.6.1.4.1.318.1.1.13.1.4.3 | airFMSysSetup | 16 | 32 | None |
1.3.6.1.4.1.318.1.1.13.1.4.4 | airFMSysConfig | 10 | 20 | None |
1.3.6.1.4.1.318.1.1.13.1.4.5 | airFMSysCooling | 23 | 46 | None |
1.3.6.1.4.1.318.1.1.13.1.4.6 | airFMSysHumidify | 7 | 14 | None |
1.3.6.1.4.1.318.1.1.13.1.4.7 | airFMSysDehumidify | 9 | 18 | None |
1.3.6.1.4.1.318.1.1.13.1.4.8 | airFMSysReheat | 10 | 20 | None |
1.3.6.1.4.1.318.1.1.13.1.4.9 | airFMSysThresholds | 16 | 32 | None |
1.3.6.1.4.1.318.1.1.13.1.4.10 | airFMSysInputs | 2 | 10 | None |
1.3.6.1.4.1.318.1.1.13.1.4.11 | airFMSysOutputs | 2 | 7 | None |
1.3.6.1.4.1.318.1.1.13.1.4.12 | airFMSysAlarmMap | 6 | 126 | None |