Reference record for OID 1.3.6.1.4.1.318.1.1.13.1.4.5.13



parent
1.3.6.1.4.1.318.1.1.13.1.4.5 (airFMSysCooling)
node code
13
node name
airFMSysCoolDeadbandF
dot oid
1.3.6.1.4.1.318.1.1.13.1.4.5.13
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysCooling(5) airFMSysCoolDeadbandF(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysCooling(5) airFMSysCoolDeadbandF(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysCooling(5) airFMSysCoolDeadbandF(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysCooling(5) airFMSysCoolDeadbandF(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysCooling(5) airFMSysCoolDeadbandF(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysCooling(5) airFMSysCoolDeadbandF(13)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysCooling/airFMSysCoolDeadbandF
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysCooling/airFMSysCoolDeadbandF
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysCooling/airFMSysCoolDeadbandF
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysCooling/airFMSysCoolDeadbandF
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysCooling/airFMSysCoolDeadbandF
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysCooling/airFMSysCoolDeadbandF
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/13/1/4/5/13

    Description by mibdepot

    The temperature range that controls output when the
    selected control sensor temperature is above the
    setpoint. At the top of this range, the cool mode
    outputs at 100%. The deadband does not apply to PID-
    controlled modes. Measured in tenths of degrees
    Fahrenheit.
    A value of -2147483648 indicates that this OID does
    not apply to this device due to its configuration.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    The temperature range that controls output when the
    selected control sensor temperature is above the
    setpoint. At the top of this range, the cool mode
    outputs at 100%. The deadband does not apply to PID-
    controlled modes. Measured in tenths of degrees
    Fahrenheit.
    A value of -2147483648 indicates that this OID does
    not apply to this device due to its configuration.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    airFMSysCoolDeadbandF OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysCooling 13 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    airFMSysCoolDeadbandF OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysCooling 13 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.13.1.4.5.13.0 airFMSysCoolDeadbandF 0 0 None

    Brothers (22)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.13.1.4.5.1 airFMSysCompMinOnTime 1 1 Set the minimum time the compressor continues to
    operate after it is started. The delay protects the
    compressor from damage. Caut…
    1.3.6.1.4.1.318.1.1.13.1.4.5.2 airFMSysCompMinOffTime 1 1 airFMSysCompMinOfftime
    1.3.6.1.4.1.318.1.1.13.1.4.5.3 airFMSysCompRotPeriod 1 1 Set how often to perform compressor runtime
    balancing. Measured in hours.
    A value of -2147483648 indicates that this OID does
    not…
    1.3.6.1.4.1.318.1.1.13.1.4.5.4 airFMSysEconIsolVlvOpenDelay 1 1 Set the delay between opening the Economizer Isolator
    output relay and engaging the compressors. Measured
    in seconds.
    A value of …
    1.3.6.1.4.1.318.1.1.13.1.4.5.5 airFMSysEconIsolVlvCloseDelay 1 1 Set the delay between disengaging the compressor and
    closing the Economizer Isolator output relay.
    Measured in seconds.
    A value of…
    1.3.6.1.4.1.318.1.1.13.1.4.5.6 airFMSysCndsrFluidVlvCloseDelay 1 1 Set the time the condenser valve remains open after
    the compressors disengage. Measured in seconds.
    A value of -2147483648 indic…
    1.3.6.1.4.1.318.1.1.13.1.4.5.7 airFMSysInterstageDelay 1 1 The DX interstage delay allows the first compressor's
    cooling to take effect before engaging the second
    compressor. This prevents…
    1.3.6.1.4.1.318.1.1.13.1.4.5.8 airFMSysCoolState 1 1 Set the mode to enabled or disabled. Disabled modes
    will not operate, and you cannot make changes to
    their settings while they ar…
    1.3.6.1.4.1.318.1.1.13.1.4.5.9 airFMSysCoolEssFunction 1 1 Set the priority of the mode for alarms and events
    with the nonessential stop behavior. Nonessential
    modes are disabled during no…
    1.3.6.1.4.1.318.1.1.13.1.4.5.10 airFMSysCoolSetpointC 1 1 The target value for the selected control sensor air
    for this mode. It must be at least 1.0 C above the
    reheat setpoint if a heat…
    1.3.6.1.4.1.318.1.1.13.1.4.5.11 airFMSysCoolSetpointF 1 1 The target value for the selected control sensor air
    for this mode. It must be at least 1.0 C above the
    reheat setpoint if a heat…
    1.3.6.1.4.1.318.1.1.13.1.4.5.12 airFMSysCoolDeadbandC 1 1 The temperature range that controls output when the
    selected control sensor temperature is above the
    setpoint. At the top of this…
    1.3.6.1.4.1.318.1.1.13.1.4.5.14 airFMSysCoolEconIsolFunction 1 1 Set the Economizer Automatic Coolant Isolation valve
    to enabled or disabled. This valve anticipates a
    cooling demand and opens th…
    1.3.6.1.4.1.318.1.1.13.1.4.5.15 airFMSysSuctPresCompensation 1 1 Set the Suction Pressure Compensation to enabled or
    disabled. This function attempts to keep the suction
    pressure from exceeding …
    1.3.6.1.4.1.318.1.1.13.1.4.5.16 airFMSysCoilFluidActivThreshC 1 1 The minimum coolant temperature required to use the
    optional MultiCool or Economizer coil. Measured in
    tenths of degrees Celsius…
    1.3.6.1.4.1.318.1.1.13.1.4.5.17 airFMSysCoilFluidActivThreshF 1 1 The minimum coolant temperature required to use the
    optional MultiCool or Economizer coil. Measured in
    tenths of degrees Fahrenh…
    1.3.6.1.4.1.318.1.1.13.1.4.5.18 airFMSysCoilFluidActivDeadbandC 1 1 The controller will disengage the MultiCool or
    Economizer coil when the coolant temperature reaches
    the coil fluid temperature ac…
    1.3.6.1.4.1.318.1.1.13.1.4.5.19 airFMSysCoilFluidActivDeadbandF 1 1 The controller will disengage the MultiCool or
    Economizer coil when the coolant temperature reaches
    the coil fluid temperature ac…
    1.3.6.1.4.1.318.1.1.13.1.4.5.20 airFMSysCoolPIDMethod 1 1 Set the multipliers that the PID algorithm will use
    to calculate the cool output. Proportional,
    Proportional + Integral, or Propo…
    1.3.6.1.4.1.318.1.1.13.1.4.5.21 airFMSysCoolPIDGainP 1 1 Set the proportional multiplier to correct for
    differences between the selected control sensor
    actual temperature and the setpoin…
    1.3.6.1.4.1.318.1.1.13.1.4.5.22 airFMSysCoolPIDResetRateI 1 1 Set the integral multiplier to correct for the
    proportional offset. Measured in %/(C * min).
    A value of -2147483648 indicates th…
    1.3.6.1.4.1.318.1.1.13.1.4.5.23 airFMSysCoolPIDDerivativeD 1 1 Set the derivative multiplier to counteract overshoot
    and droop during changes in the room load. Measured
    in %/(C / min).
    A value…