Reference record for OID 1.3.6.1.4.1.318.1.1.13.1.4.8.7



parent
1.3.6.1.4.1.318.1.1.13.1.4.8 (airFMSysReheat)
node code
7
node name
airFMSysReheatPIDMethod
dot oid
1.3.6.1.4.1.318.1.1.13.1.4.8.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysReheat(8) airFMSysReheatPIDMethod(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysReheat(8) airFMSysReheatPIDMethod(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysReheat(8) airFMSysReheatPIDMethod(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysReheat(8) airFMSysReheatPIDMethod(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysReheat(8) airFMSysReheatPIDMethod(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) airConditioners(13) airFM(1) airFMSystem(4) airFMSysReheat(8) airFMSysReheatPIDMethod(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysReheat/airFMSysReheatPIDMethod
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysReheat/airFMSysReheatPIDMethod
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysReheat/airFMSysReheatPIDMethod
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysReheat/airFMSysReheatPIDMethod
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysReheat/airFMSysReheatPIDMethod
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/airConditioners/airFM/airFMSystem/airFMSysReheat/airFMSysReheatPIDMethod
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/13/1/4/8/7

    Description by mibdepot

    Set the multipliers that the PID algorithm will use
    to calculate the output. Proportional,
    Proportional + Integral, or Proportional + Integral
    + Derivative.
    A value of notApplicable indicates that this OID does
    not apply to this device due to its configuration.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Set the multipliers that the PID algorithm will use
    to calculate the output. Proportional,
    Proportional + Integral, or Proportional + Integral
    + Derivative.
    A value of notApplicable indicates that this OID does
    not apply to this device due to its configuration.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    airFMSysReheatPIDMethod OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), p (2), pi (3), pid (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysReheat 7 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    airFMSysReheatPIDMethod OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), p (2), pi (3), pid (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysReheat 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.13.1.4.8.7.0 airFMSysReheatPIDMethod 0 0 None

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.13.1.4.8.1 airFMSysReheatState 1 1 Set the mode to enabled or disabled. Disabled modes
    will not operate, and you cannot make changes to their
    settings while they ar…
    1.3.6.1.4.1.318.1.1.13.1.4.8.2 airFMSysReheatEssFunction 1 1 Set the priority of the mode for alarms and events
    with the nonessential stop behavior. Nonessential
    modes are disabled during no…
    1.3.6.1.4.1.318.1.1.13.1.4.8.3 airFMSysReheatSetpointC 1 1 The target value for the selected control sensor air
    for this mode. It must be at least 1.0 C below the
    cooling setpoint. Measur…
    1.3.6.1.4.1.318.1.1.13.1.4.8.4 airFMSysReheatSetpointF 1 1 The target value for the selected control sensor air
    for this mode. It must be at least 1.0 C below the
    cooling setpoint. Measur…
    1.3.6.1.4.1.318.1.1.13.1.4.8.5 airFMSysReheatDeadbandC 1 1 The temperature range that controls output when the
    selected control sensor temperature is below the
    setpoint. At the bottom of t…
    1.3.6.1.4.1.318.1.1.13.1.4.8.6 airFMSysReheatDeadbandF 1 1 The temperature range that controls output when the
    selected control sensor temperature is below the
    setpoint. At the bottom of t…
    1.3.6.1.4.1.318.1.1.13.1.4.8.8 airFMSysReheatPIDGainP 1 1 Set the proportional multiplier to correct for
    differences between the selected control sensor
    actual temperature and the setpoin…
    1.3.6.1.4.1.318.1.1.13.1.4.8.9 airFMSysReheatPIDResetRateI 1 1 Set the integral multiplier to correct for the
    proportional offset. Measured in %/(C * min).
    A value of -2147483648 indicates th…
    1.3.6.1.4.1.318.1.1.13.1.4.8.10 airFMSysReheatPIDDerivativeD 1 1 Set the derivative multiplier to counteract overshoot
    and droop during changes in the room load. Measured
    in %/(C / min).
    A value…