Reference record for OID 1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.5



parent
1.3.6.1.4.1.326.2.2.1.1.4.1.1.1 (sonetConfEntry)
node code
5
node name
sonetLineCoding
dot oid
1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fore(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) marconi(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) fore(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) marconi(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) fore(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) marconi(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) fore(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) marconi(326) systems(2) atmSwitch(2) hardware(1) asx(1) foreSonetModule(4) sonetConfGroup(1) sonetConfTable(1) sonetConfEntry(1) sonetLineCoding(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/fore/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • /iso/identified-organization/dod/internet/private/enterprise/marconi/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/fore/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • /iso/org/dod/internet/private/enterprise/marconi/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • /iso/org/dod/internet/private/enterprises/fore/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • /iso/org/dod/internet/private/enterprises/marconi/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/fore/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • /iso/iso-identified-organization/dod/internet/private/enterprises/marconi/systems/atmSwitch/hardware/asx/foreSonetModule/sonetConfGroup/sonetConfTable/sonetConfEntry/sonetLineCoding
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/326/2/2/1/1/4/1/1/1/5

    Description by mibdepot

    This variable describes the line coding for this interface. The B3ZS and CMI
    are used for electrical SONET signals (STS-1 and STS-3). The Non-Return to
    Zero (NRZ) and the Return to Zero (RZ) are used for optical SONET signals.
    This variable is defined in the SONET IETF draft photonic table as
    sonetPhotonicLineCoding.

    Parsed from file fore-sonet.mib.txt
    Company: None
    Module: Fore-SONET-MIB

    Description by circitor

    This variable describes the line coding for this interface. The B3ZS and CMI
    are used for electrical SONET signals (STS-1 and STS-3). The Non-Return to
    Zero (NRZ) and the Return to Zero (RZ) are used for optical SONET signals.
    This variable is defined in the SONET IETF draft photonic table as
    sonetPhotonicLineCoding.

    Parsed from file Fore-SONET-MIB.mib
    Module: Fore-SONET-MIB

    Information by oid_info

    Vendor: Fore Systems, Inc.
    Module: Fore-SONET-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    sonetLineCoding OBJECT-TYPE SYNTAX INTEGER { sonetOther(1), sonetB3ZS(2), sonetCMI(3), sonetNRZ(4), sonetRZ(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable describes the line coding for this interface. The B3ZS and CMI are used for electrical SONET signals (STS-1 and STS-3). The Non-Return to Zero (NRZ) and the Return to Zero (RZ) are used for optical SONET signals. This variable is defined in the SONET IETF draft photonic table as sonetPhotonicLineCoding." DEFVAL { sonetNRZ } ::= { sonetConfEntry 5 }

    Information by circitor

    sonetLineCoding OBJECT-TYPE SYNTAX INTEGER { sonetOther(1), sonetB3ZS(2), sonetCMI(3), sonetNRZ(4), sonetRZ(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable describes the line coding for this interface. The B3ZS and CMI are used for electrical SONET signals (STS-1 and STS-3). The Non-Return to Zero (NRZ) and the Return to Zero (RZ) are used for optical SONET signals. This variable is defined in the SONET IETF draft photonic table as sonetPhotonicLineCoding." DEFVAL { sonetNRZ } ::= { sonetConfEntry 5 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.326)

    Cooper Eric

    Brothers (36)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.1 sonetConfBoard 0 0 The index of this port's switch board.
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.2 sonetConfModule 0 0 The network module of this port.
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.3 sonetConfPort 0 0 The number of this port.
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.4 sonetLineType 0 0 This variable describes the line type for this interface. The line type for
    optical SONET signals may be single-mode (short or l…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.6 sonetFramingStandardDefault 0 0 This variable identify the default value of the framing standard that
    is used by this port (SONET or SDH).
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.7 sonetFramingStandardOper 0 0 This variable identify the operational value of the framing standard that
    is used by this port (SONET or SDH).
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.8 sonetPathWidth 0 0 This variable indicates the type of the SONET Path. Assigned types are the
    STS-Nc Synchronous Payload Envelopes where N=1,3,9,12…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.9 sonetLoopbackConfig 0 0 This variable represents the current loopback status of the
    SONET interface.
    The possible values are:
    sonetNoLoop (1) means that t…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.10 sonetTxClockSource 0 0 The source of the transmit clock.
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.11 sonetRxScrambling 0 0 This variable indicates whether the information is being descrambled
    on receiving. It should be set the same as the transmitting…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.12 sonetTxScrambling 0 0 This variable indicates whether the information (48 octet payload) is being
    scrambled before transmitting. It should be set the …
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.13 sonetSectionStatus 0 0 This variable indicates the Section Status of the interface. It is defined in
    the SONET IETF draft section configuration table a…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.14 sonetLineStatus 0 0 This variable indicates the Line Status of the interface. A similar variable is
    defined in the SONET IETF draft line configurati…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.15 sonetPathStatus 0 0 This variable indicates the Path Status of the interface. It is defined in
    the SONET IETF draft path configuration table as sone…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.16 sonetIdleUnassignedCells 0 0 This variable indicates the type of cells that should be sent in
    case there is no data to send. According to the ATM Forum, Unas…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.17 sonetAtmStatus 0 0 This variable indicates the ATM Status of the interface. The variable
    is a bit map represented as a sum, therefore, it can repr…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.18 sonetLineAis 0 0 This variable controls the insertion of line alarm
    indication signal (AIS_L). When set to sonetLineAisOn,
    AIS is inserted into t…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.19 sonetLineRdi 0 0 The variable controls the insertion of Line Remote
    Defect Indication (RDI_L). When set to
    sonetLineRdiAuto, RDI_L is automatical…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.20 sonetPathAis 0 0 This variable controls the insertion of STS Path
    Alarm Indication Signal (AIS_P). When set to
    sonetPathAisOn, the complete SPE, …
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.21 sonetPathRdi 0 0 This variable controls the insertion of Path Remote
    Defect Indication (RDI_P). When set to
    sonetPathRdiAuto, RDI_P is automatica…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.22 sonetFebe 0 0 This variable controls the insertion of line and path
    far end block errors. When set to sonetFebeAuto, one
    line or path FEBE is …
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.23 sonetRxPathSignalLabel 0 0 This variable contains the path signal label byte
    (C2). The value in this variable is updated to a new
    path signal label value i…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.24 sonetTxPathSignalLabel 0 0 This variable controls the transmit path signal label.
    The default value for ATM is 0x13 (19 decimal).
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.25 sonetArbitraryPointer 0 0 This variable controls bits APTR[9:0] of arbitrary
    pointer register. It may be used along with the
    sonetPathPointerDiagnostic va…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.26 sonetSectionDiagnostic 0 0 This variable controls the insertion of various types
    of section diagnostic bit patterns in the transmit
    stream. It is a bit map…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.27 sonetLineDiagnostic 0 0 This variable controls the insertion of various types
    of line diagnostic bit patterns in the transmit
    stream. It is a bit map th…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.28 sonetPathDiagnostic 0 0 This variable controls the insertion of various types
    of path diagnostic bit patterns in the transmit
    stream. It is a bit map th…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.29 sonetPathPointerDiagnostic 0 0 This variable controls the insertion of various types
    of path pointer diagnostic bit patterns in the transmit
    stream. It is a bi…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.30 sonetAtmDiagnostic 0 0 This variable controls the insertion of various types
    of atm diagnostic bit patterns in the transmit
    stream. It is a bit map tha…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.31 sonetLineBipThrSeconds 0 0 This variable represents the consecutive number of
    BAD/GOOD seconds to detect/clear a B2 byte Line Bit
    Interleaved Parity (BIP) D…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.32 sonetLineBipThrErrors 0 0 This variable is a threshold for the number of B2 byte
    Line Bit Interleaved Parity (BIP) Errors per second
    and is used as a param…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.33 sonetLineBipFailEnable 0 0 This variable controls whether declaration of a
    Line BIP Defect forces the port's operState to Down.
    This variable is only applic…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.34 sonetLineSignalDegradeBer 0 0 This is the exponent of 10 for the current signal
    degrade bit error rate (BER) threshold for this port.
    The value -7, for example…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.35 sonetLineSignalFailBer 0 0 This is the exponent of 10 for the current signal
    fail bit error rate (BER) threshold for this port.
    The value -4, for example, r…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.36 sonetLineBerErrorModel 0 0 This is the error distribution model to be used to
    identify signal degrade and signal fail conditions.
    errorModelRandom selects a…
    1.3.6.1.4.1.326.2.2.1.1.4.1.1.1.37 sonetLineBerState 0 0 This value describes the current state of the port as
    determined through bit error rate analysis.