stackUnitNotepad OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE(0..512))
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object is used to store user-specified data regarding
this unit. The user may store any relevant data about the unit. This
may include its floor location, history or other details. The unit
stores the data in non-volatile storage so that the data is not lost
over a normal reset. The data will be cleared if the unit is returned
to factory defaults. A maximum of 512 characters of data may be stored
in this object.
This object can be treated as a displayString. In the MIB it is defined
as an OCTET STRING since displayStrings are not allowed to be more than
255 characters in length."
View at oid-info.com
This object is used to store user-specified data
regarding this unit. The user may store any relevant data about
the unit. This may include its floor location, history or other
details. The unit stores the data in non-volatile storage so
that the data is not lost over a normal reset. The data will be
cleared if the unit is returned to factory defaults. A maximum
of 512 characters of data may be stored in this object.
This object can be treated as a displayString. In the MIB it is
defined as an OCTET STRING since displayStrings are not allowed
to be more than 255 characters in length.
Parsed from file 3COM0352.MIB.txt
Company: a3com
Module: A3COM0352-STACK-CONFIG
Automatically extracted from a file named S3M_AGENT
stackUnitNotepad OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..512)) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to store user-specified data regarding this unit. The user may store any relevant data about the unit. This may include its floor location, history or other details. The unit stores the data in non-volatile storage so that the data is not lost over a normal reset. The data will be cleared if the unit is returned to factory defaults. A maximum of 512 characters of data may be stored in this object. This object can be treated as a displayString. In the MIB it is defined as an OCTET STRING since displayStrings are not allowed to be more than 255 characters in length." ::= {stackConfigEntry 18}
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.43.10.27.1.1.1.1 | stackUnitLocation | 0 | 0 | Used to identify individual units in the stack. Note that this value will usually be contiguous, but that gaps may be present du… |
| 1.3.6.1.4.1.43.10.27.1.1.1.2 | stackUnitAddress | 0 | 0 | Every conformant unit in the SuperStack II system will have a unique physical (MAC) address by which it can be recognised. Note t… |
| 1.3.6.1.4.1.43.10.27.1.1.1.3 | stackUnitLastReset | 0 | 0 | This is the time in hundredths of a second, since this unit last reset (ie that units concept of sysUpTime). Note that if a unit… |
| 1.3.6.1.4.1.43.10.27.1.1.1.4 | stackUnitType | 0 | 0 | This is an integer type identifier for this unit. The values of this integer are administered by allocating a MIB object identif… |
| 1.3.6.1.4.1.43.10.27.1.1.1.5 | stackUnitDesc | 0 | 0 | This is a text string which describes this unit. If a unit cannot provide a name then the value of this object will be an empty s… |
| 1.3.6.1.4.1.43.10.27.1.1.1.6 | stackUnitName | 0 | 0 | This is a simple text string which can be used by an application to assign a text name to a unit. By default this string is empty… |
| 1.3.6.1.4.1.43.10.27.1.1.1.7 | stackUnitState | 0 | 0 | This object represents the best known state of a unit in the stack. The unknown state is not expected to be used, but may exist b… |
| 1.3.6.1.4.1.43.10.27.1.1.1.8 | stackUnitManagementType | 0 | 0 | This object can be used to determine the management method used to access the agent in this unit. The options are: unknown: T… |
| 1.3.6.1.4.1.43.10.27.1.1.1.9 | stackUnitCapabilities | 0 | 0 | This object describes the capabilities of this particular unit. This is used in conjunction with the upgrade level of the stack t… |
| 1.3.6.1.4.1.43.10.27.1.1.1.10 | stackUnitPromVersion | 0 | 0 | This is the version number of the PROM on the unit. If the unit has no PROM, does not correctly report the PROM version or is cur… |
| 1.3.6.1.4.1.43.10.27.1.1.1.11 | stackUnitHWVersion | 0 | 0 | This is the hardware version of this unit, expressed as a string. Note that if the hardware version is not available for this par… |
| 1.3.6.1.4.1.43.10.27.1.1.1.12 | stackUnitSWVersion | 0 | 0 | This is the software version number of this unit. The software version number is a string. Note that if a unit does not make its … |
| 1.3.6.1.4.1.43.10.27.1.1.1.13 | stackUnitSerialNumber | 0 | 0 | This is the serial number for this unit. The number is globally unique and expressed as a textual string. |
| 1.3.6.1.4.1.43.10.27.1.1.1.14 | stackUnitAttention | 0 | 0 | Some of the units in the stack will contain a mechanism for drawing attention to that unit. This is useful for directing maintain… |
| 1.3.6.1.4.1.43.10.27.1.1.1.15 | stackUnitMgmtInterface | 0 | 0 | If a unit in the stack participates in the distributed SNMP stack then it will have an instance of this object (stackUnitManageme… |
| 1.3.6.1.4.1.43.10.27.1.1.1.16 | stackUnitSummary | 0 | 0 | stackUnitSummary OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary … |
| 1.3.6.1.4.1.43.10.27.1.1.1.17 | stackUnitSlipMgmtInterface | 0 | 0 | If a unit in the stack participates in the distributed SNMP stack then it will have an instance of this object (stackUnitManageme… |
| 1.3.6.1.4.1.43.10.27.1.1.1.19 | stackUnitProductNumber | 0 | 0 | This is a textual representation of the unit's product number. Note that if a unit does not make its product number information a… |