Reference record for OID 1.3.6.1.4.1.498.19.1.4.1.1



parent
1.3.6.1.4.1.498.19.1.4.1 (sc800t3MaintenanceTable)
node code
1
node name
sc800t3MaintenanceEntry
dot oid
1.3.6.1.4.1.498.19.1.4.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry
  • /iso/identified-organization/dod/internet/private/enterprises/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry
  • /iso/org/dod/internet/private/enterprise/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry
  • /iso/org/dod/internet/private/enterprises/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/498/19/1/4/1/1

    Description by mibdepot

    An entry in the GDC maintenance Table

    Parsed from file gdcsc800t3.mib.txt
    Company: None
    Module: GDC-SC800T3-MIB

    Description by circitor

    An entry in the GDC maintenance Table

    Parsed from file GDC-SC800T3-MIB.mib
    Module: GDC-SC800T3-MIB

    Information by mibdepot

    sc800t3MaintenanceEntry OBJECT-TYPE SYNTAX Sc800t3MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC maintenance Table" INDEX { sc800t3MaintenanceIndex } ::= { sc800t3MaintenanceTable 1 }

    Information by oid_info

    Vendor: General DataComm, Inc.
    Module: GDC-SC800T3-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    sc800t3MaintenanceEntry OBJECT-TYPE SYNTAX Sc800t3MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC maintenance Table" INDEX { sc800t3MaintenanceIndex } ::= { sc800t3MaintenanceTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.498)

    Meltzer William

    Children (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.498.19.1.4.1.1.1 sc800t3MaintenanceIndex 0 0 Integer value which uniquely identifies the SC800T3 to which this
    entry is applicable. SCinstance is defined to be SLDi where:
    S …
    1.3.6.1.4.1.498.19.1.4.1.1.2 sc800t3LedStatus 0 0 Returns a bitwise snapshot of the front panel LED state and front panel switches.
    Octet 1 bit 7 - f/u
    bit 6 - NTWK …
    1.3.6.1.4.1.498.19.1.4.1.1.3 sc800t3SoftReset 0 0 Supports the action of soft resetting the unit. When this
    object is set to reset(1), then the unit performs a soft reset.
    The va…
    1.3.6.1.4.1.498.19.1.4.1.1.4 sc800t3DefaultInit 0 0 This is used to allow the NonVolatile Configuration to be set to
    a factory default state. When this value is set to factoryDefa…
    1.3.6.1.4.1.498.19.1.4.1.1.5 sc800t3ValidNearEndIntervals 0 0 The number of previous near end intervals for which
    valid data was collected. The value will be 31
    unless the interface was …
    1.3.6.1.4.1.498.19.1.4.1.1.6 sc800t3ValidFarEndIntervals 0 0 The number of previous far end intervals for which
    valid data was collected. The value will be 31
    unless the interface was b…
    1.3.6.1.4.1.498.19.1.4.1.1.7 sc800t3ShelfType 0 0 sc800t3Shelftype
    1.3.6.1.4.1.498.19.1.4.1.1.8 sc800t3TwinPackPowerSupply 0 0 Power supplies currently installed in Twin Pack. When the sc800t3 is located in
    a Spectracomm shelf none(1) will always be retur…
    1.3.6.1.4.1.498.19.1.4.1.1.9 sc800t3TestAllLeds 0 0 This variable is used to test the front panel leds and individual
    segments of the display. A one (1) will turn all leds and dis…
    1.3.6.1.4.1.498.19.1.4.1.1.10 sc800t3NearEndResetStats 0 0 Supports the action of soft resetting the sc800t3ValidNearEndIntervals
    object. When this object is set to reset(2), then the un…
    1.3.6.1.4.1.498.19.1.4.1.1.11 sc800t3FarEndResetStats 0 0 Supports the action of soft resetting the sc800t3ValidFarEndIntervals
    object. When this object is set to reset(2), then the uni…
    1.3.6.1.4.1.498.19.1.4.1.1.12 sc800t3NearEndStatLastInitial 0 0 Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was
    last initialized to zero.
    1.3.6.1.4.1.498.19.1.4.1.1.13 sc800t3FarEndStatLastInitial 0 0 Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was
    last initialized to zero.