Reference record for OID 1.3.6.1.4.1.498.19.1.4.1.1.10



parent
1.3.6.1.4.1.498.19.1.4.1.1 (sc800t3MaintenanceEntry)
node code
10
node name
sc800t3NearEndResetStats
dot oid
1.3.6.1.4.1.498.19.1.4.1.1.10
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1) sc800t3NearEndResetStats(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1) sc800t3NearEndResetStats(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1) sc800t3NearEndResetStats(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1) sc800t3NearEndResetStats(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1) sc800t3NearEndResetStats(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) ds3(19) sc800t3(1) sc800t3Maintenance(4) sc800t3MaintenanceTable(1) sc800t3MaintenanceEntry(1) sc800t3NearEndResetStats(10)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry/sc800t3NearEndResetStats
  • /iso/identified-organization/dod/internet/private/enterprises/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry/sc800t3NearEndResetStats
  • /iso/org/dod/internet/private/enterprise/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry/sc800t3NearEndResetStats
  • /iso/org/dod/internet/private/enterprises/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry/sc800t3NearEndResetStats
  • /iso/iso-identified-organization/dod/internet/private/enterprise/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry/sc800t3NearEndResetStats
  • /iso/iso-identified-organization/dod/internet/private/enterprises/gdc/ds3/sc800t3/sc800t3Maintenance/sc800t3MaintenanceTable/sc800t3MaintenanceEntry/sc800t3NearEndResetStats
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/498/19/1/4/1/1/10

    Description by mibdepot

    Supports the action of soft resetting the sc800t3ValidNearEndIntervals
    object. When this object is set to reset(2), then the unit
    will reset the sc800t3ValidNearEndIntervals object to zero.
    The value of norm(1) can not be set by management.

    Parsed from file gdcsc800t3.mib.txt
    Company: None
    Module: GDC-SC800T3-MIB

    Description by circitor

    Supports the action of soft resetting the sc800t3ValidNearEndIntervals
    object. When this object is set to reset(2), then the unit
    will reset the sc800t3ValidNearEndIntervals object to zero.
    The value of norm(1) can not be set by management.

    Parsed from file GDC-SC800T3-MIB.mib
    Module: GDC-SC800T3-MIB

    Information by mibdepot

    sc800t3NearEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidNearEndIntervals object to zero. The value of norm(1) can not be set by management." ::= { sc800t3MaintenanceEntry 10 }

    Information by oid_info

    Vendor: General DataComm, Inc.
    Module: GDC-SC800T3-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    sc800t3NearEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidNearEndIntervals object to zero. The value of norm(1) can not be set by management." ::= { sc800t3MaintenanceEntry 10 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.498)

    Meltzer William

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.498.19.1.4.1.1.1 sc800t3MaintenanceIndex 0 0 Integer value which uniquely identifies the SC800T3 to which this
    entry is applicable. SCinstance is defined to be SLDi where:
    S …
    1.3.6.1.4.1.498.19.1.4.1.1.2 sc800t3LedStatus 0 0 Returns a bitwise snapshot of the front panel LED state and front panel switches.
    Octet 1 bit 7 - f/u
    bit 6 - NTWK …
    1.3.6.1.4.1.498.19.1.4.1.1.3 sc800t3SoftReset 0 0 Supports the action of soft resetting the unit. When this
    object is set to reset(1), then the unit performs a soft reset.
    The va…
    1.3.6.1.4.1.498.19.1.4.1.1.4 sc800t3DefaultInit 0 0 This is used to allow the NonVolatile Configuration to be set to
    a factory default state. When this value is set to factoryDefa…
    1.3.6.1.4.1.498.19.1.4.1.1.5 sc800t3ValidNearEndIntervals 0 0 The number of previous near end intervals for which
    valid data was collected. The value will be 31
    unless the interface was …
    1.3.6.1.4.1.498.19.1.4.1.1.6 sc800t3ValidFarEndIntervals 0 0 The number of previous far end intervals for which
    valid data was collected. The value will be 31
    unless the interface was b…
    1.3.6.1.4.1.498.19.1.4.1.1.7 sc800t3ShelfType 0 0 sc800t3Shelftype
    1.3.6.1.4.1.498.19.1.4.1.1.8 sc800t3TwinPackPowerSupply 0 0 Power supplies currently installed in Twin Pack. When the sc800t3 is located in
    a Spectracomm shelf none(1) will always be retur…
    1.3.6.1.4.1.498.19.1.4.1.1.9 sc800t3TestAllLeds 0 0 This variable is used to test the front panel leds and individual
    segments of the display. A one (1) will turn all leds and dis…
    1.3.6.1.4.1.498.19.1.4.1.1.11 sc800t3FarEndResetStats 0 0 Supports the action of soft resetting the sc800t3ValidFarEndIntervals
    object. When this object is set to reset(2), then the uni…
    1.3.6.1.4.1.498.19.1.4.1.1.12 sc800t3NearEndStatLastInitial 0 0 Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was
    last initialized to zero.
    1.3.6.1.4.1.498.19.1.4.1.1.13 sc800t3FarEndStatLastInitial 0 0 Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was
    last initialized to zero.