This is used to allow the NonVolatile Configuration to be set to
a factory default state. When this value is set to factoryDefault,
the unit will reset to the default configuration. The value of normal
will be returned when the initialization is complete. The value normal
can not be set by management.
Parsed from file gdcsc800t3.mib.txt
Company: None
Module: GDC-SC800T3-MIB
This is used to allow the NonVolatile Configuration to be set to
a factory default state. When this value is set to factoryDefault,
the unit will reset to the default configuration. The value of normal
will be returned when the initialization is complete. The value normal
can not be set by management.
Parsed from file GDC-SC800T3-MIB.mib
Module: GDC-SC800T3-MIB
sc800t3DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), factoryDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault, the unit will reset to the default configuration. The value of normal will be returned when the initialization is complete. The value normal can not be set by management." ::= { sc800t3MaintenanceEntry 4 }
Vendor: General DataComm, Inc.
Module: GDC-SC800T3-MIB
[Automatically extracted from oidview.com]
sc800t3DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), factoryDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault, the unit will reset to the default configuration. The value of normal will be returned when the initialization is complete. The value normal can not be set by management." ::= { sc800t3MaintenanceEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.19.1.4.1.1.1 | sc800t3MaintenanceIndex | 0 | 0 | Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S … |
1.3.6.1.4.1.498.19.1.4.1.1.2 | sc800t3LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state and front panel switches. Octet 1 bit 7 - f/u bit 6 - NTWK … |
1.3.6.1.4.1.498.19.1.4.1.1.3 | sc800t3SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset. The va… |
1.3.6.1.4.1.498.19.1.4.1.1.5 | sc800t3ValidNearEndIntervals | 0 | 0 | The number of previous near end intervals for which valid data was collected. The value will be 31 unless the interface was … |
1.3.6.1.4.1.498.19.1.4.1.1.6 | sc800t3ValidFarEndIntervals | 0 | 0 | The number of previous far end intervals for which valid data was collected. The value will be 31 unless the interface was b… |
1.3.6.1.4.1.498.19.1.4.1.1.7 | sc800t3ShelfType | 0 | 0 | sc800t3Shelftype |
1.3.6.1.4.1.498.19.1.4.1.1.8 | sc800t3TwinPackPowerSupply | 0 | 0 | Power supplies currently installed in Twin Pack. When the sc800t3 is located in a Spectracomm shelf none(1) will always be retur… |
1.3.6.1.4.1.498.19.1.4.1.1.9 | sc800t3TestAllLeds | 0 | 0 | This variable is used to test the front panel leds and individual segments of the display. A one (1) will turn all leds and dis… |
1.3.6.1.4.1.498.19.1.4.1.1.10 | sc800t3NearEndResetStats | 0 | 0 | Supports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the un… |
1.3.6.1.4.1.498.19.1.4.1.1.11 | sc800t3FarEndResetStats | 0 | 0 | Supports the action of soft resetting the sc800t3ValidFarEndIntervals object. When this object is set to reset(2), then the uni… |
1.3.6.1.4.1.498.19.1.4.1.1.12 | sc800t3NearEndStatLastInitial | 0 | 0 | Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was last initialized to zero. |
1.3.6.1.4.1.498.19.1.4.1.1.13 | sc800t3FarEndStatLastInitial | 0 | 0 | Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was last initialized to zero. |