The number of previous near end intervals for which
valid data was collected. The value will be 31
unless the interface was brought on-line within
the last 7.75 hours, in which case the value will
be the number of complete 15 minute intervals
since the interface has been online.
Parsed from file gdcsc800t3.mib.txt
Company: None
Module: GDC-SC800T3-MIB
The number of previous near end intervals for which
valid data was collected. The value will be 31
unless the interface was brought on-line within
the last 7.75 hours, in which case the value will
be the number of complete 15 minute intervals
since the interface has been online.
Parsed from file GDC-SC800T3-MIB.mib
Module: GDC-SC800T3-MIB
sc800t3ValidNearEndIntervals OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online." ::= { sc800t3MaintenanceEntry 5 }
Vendor: General DataComm, Inc.
Module: GDC-SC800T3-MIB
[Automatically extracted from oidview.com]
sc800t3ValidNearEndIntervals OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online." ::= { sc800t3MaintenanceEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.19.1.4.1.1.1 | sc800t3MaintenanceIndex | 0 | 0 | Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S … |
1.3.6.1.4.1.498.19.1.4.1.1.2 | sc800t3LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state and front panel switches. Octet 1 bit 7 - f/u bit 6 - NTWK … |
1.3.6.1.4.1.498.19.1.4.1.1.3 | sc800t3SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset. The va… |
1.3.6.1.4.1.498.19.1.4.1.1.4 | sc800t3DefaultInit | 0 | 0 | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefa… |
1.3.6.1.4.1.498.19.1.4.1.1.6 | sc800t3ValidFarEndIntervals | 0 | 0 | The number of previous far end intervals for which valid data was collected. The value will be 31 unless the interface was b… |
1.3.6.1.4.1.498.19.1.4.1.1.7 | sc800t3ShelfType | 0 | 0 | sc800t3Shelftype |
1.3.6.1.4.1.498.19.1.4.1.1.8 | sc800t3TwinPackPowerSupply | 0 | 0 | Power supplies currently installed in Twin Pack. When the sc800t3 is located in a Spectracomm shelf none(1) will always be retur… |
1.3.6.1.4.1.498.19.1.4.1.1.9 | sc800t3TestAllLeds | 0 | 0 | This variable is used to test the front panel leds and individual segments of the display. A one (1) will turn all leds and dis… |
1.3.6.1.4.1.498.19.1.4.1.1.10 | sc800t3NearEndResetStats | 0 | 0 | Supports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the un… |
1.3.6.1.4.1.498.19.1.4.1.1.11 | sc800t3FarEndResetStats | 0 | 0 | Supports the action of soft resetting the sc800t3ValidFarEndIntervals object. When this object is set to reset(2), then the uni… |
1.3.6.1.4.1.498.19.1.4.1.1.12 | sc800t3NearEndStatLastInitial | 0 | 0 | Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was last initialized to zero. |
1.3.6.1.4.1.498.19.1.4.1.1.13 | sc800t3FarEndStatLastInitial | 0 | 0 | Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was last initialized to zero. |